Diabetes mellitus is a chronic disease prevalence of which is high and continually growing. Cardiovascular disease continues to be the leading cause of death in patients with T2DM. The prevention of cardiovascular complications and the cardiovascular safety of treatments should be a primary objective when selecting treatment. Among all the drugs available, the compounds known as glucagon-like peptide-1 receptor agonists (GLP-1 RAs) appear to be not just innocuous in terms of CVD but indeed to be beneficial. GLP-1 RA actions not only translate on an improvement of well-known cardiovascular risk factors such as glycaemic control, dyslipidaemia, weight, or arterial hypertension but also might show benefits on endothelial function, coronary ischaemia, and heart failure. On the other hand, recent clinical trials aimed at studying cardiovascular episodes have been conducted with GLP-1 RAs. Only liraglutide and semaglutide have shown superiority in cardiovascular benefit compared with placebo. Although many of the mechanisms by which liraglutide and semaglutide produce a cardiovascular benefit are still unknown it would be desirable for these benefits to be incorporated into the therapeutic algorithms routinely used in clinical practice. The purpose of this review is to explore GLP-1 RA actions not only in cardiovascular risk factors (glucose, weight, and hypertension) but also the possible effects on established cardiovascular disease.
4 October 2018 in Diabetes, Obesity and Metabolism
Aim To assess the cardiovascular safety of oral semaglutide, the first tablet formulation of a glucagon‐like peptide‐1 receptor agonist. Methods PIONEER 6 is a multinational, randomised, placebo‐controlled, double‐blind trial in patients with type 2 diabetes (T2D) at high risk of cardiovascular events (defined as being: [1] ≥50 years and having established cardiovascular disease or moderate (Stage 3) chronic kidney disease [CKD], or [2] ≥60 years with ≥1 other cardiovascular risk factor). Patients were randomised to once‐daily oral semaglutide (up to 14 mg) or placebo added to standard of care. The primary composite endpoint is time to first occurrence of cardiovascular death or non‐fatal myocardial infarction or non‐fatal stroke. The primary hypothesis is to rule out an excess in cardiovascular risk with oral semaglutide by assessing non‐inferiority versus placebo for the primary endpoint (non‐inferiority margin of 1.8 for the upper boundary of the 95% confidence interval of the hazard ratio). PIONEER 6 is event‐driven, with follow up continuing until accrual of at least 122 primary outcome events. There is no pre‐defined minimal duration. Results Overall, 3,183 patients have been enrolled (mean age 66.1 years, 31.6% females) in 214 sites across 21 countries. At baseline, the mean duration of diabetes was 14.9 years, mean HbA1c was 8.2%, and 84.6% of patients had established cardiovascular disease/moderate CKD. Conclusions PIONEER 6 will provide evidence regarding the cardiovascular safety of oral semaglutide in patients with T2D and high cardiovascular risk.
19 March 2020 in BMJ Open Diabetes Research & Care
Objective Observations in real-world settings support and extend findings demonstrated in randomized controlled trials that show flash glucose monitoring improves glycemic control. In this study, Spain-specific relationships between testing frequency and glycemic parameters were investigated under real-world settings. Research design and methods Deidentified glucose and user scanning data were analyzed and readers were rank ordered into 20 equal sized groups by daily scan frequency. Glucose parameters were calculated for each group: estimated HbA1c, time below range (180 mg/dL). Glycemic variability (GV) metrics were described and data obtained from sensors in Spain and worldwide were compared. Results Spanish users (n=22 949) collected 37.1 million glucose scans, 250 million automatically recorded glucose readings, and checked glucose values via a mean of 13 scans/day. Estimated HbA1c, time below 70 mg/dL, at or below 54 mg/dL, above 180 mg/dL, and GV metrics were significantly lower in the highest compared with lowest scan rate group (39.6 to 3.9 scans/day). Time-in-range was higher for the highest versus lowest scan rate group at 15.6 vs 11.5 hours/day, respectively. GV metrics correlated positively with time below 70 mg/dL, at or below 54 mg/dL, above 180 mg/dL, and negatively with time-in-range. The relationship between glucose metrics and scan rate was similar in Spain and worldwide. However, time in hypoglycemia in Spain was higher in the groups with lower scan rates. Conclusions As seen in clinical trials, flash glucose monitoring in real-world settings allows frequent glucose checks. High scan rates are associated with the favorable glycemic markers of increased time-in-range and reduced time in hyperglycemia and hypoglycemia, and GV. The same trends, with unique nuances, are observed in both Spanish and global data.