Gerrard Drury

Mr. Gerrard Drury


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
SESean Elphick
Sean Elphick
JKJonathan Knott
Jonathan Knott
GDGerrard Drury
Gerrard Drury
TLTom Langstaff
Tom Langstaff
Duane RobinsonDuane Robinson
Duane Robinson
Increasing penetration of distributed energy resources is manifesting as voltage regulation challenges in many LV networks. Appropriate regulation of supply voltage magnitude is essential to ensure efficacy and efficiency in the operation of electricity supply networks and consumer equipment. While the theoretical impacts of supply voltage magnitude on the performance of consumer equipment, which include additional energy consumption and decreased equipment lifespan as voltage magnitude increases, are relatively well known, this has not been translated into quantitative impacts. This paper applies the outcomes of previous impact of supply voltage magnitude studies by the authors, in conjunction with domestic load models, to develop algorithms to estimate the quantitative impacts of supply voltage magnitude on consumers. The paper then applies these algorithms to calculate quantitative economic impacts that can be associated with the magnitude of the supply voltage. The outcomes of this research suggest that the per-annum impact of supply voltage magnitude on consumer equipment loss of life is potentially an order of magnitude greater than the resultant increased energy consumption based on case studies using Australian data.

5 December 2025 in Solar
Verified
Journal Article
Open access
PDF file
SESean Elphick
Sean Elphick
Duane RobinsonDuane Robinson
Duane Robinson
JKJonathan Knott
Jonathan Knott
GDGerrard Drury
Gerrard Drury
As the penetration of distributed energy resources (DERs) continues to increase, there is conjecture concerning the power quality implications of the inverters used to interface these DERs with low-voltage (LV) electricity supply networks. As a power electronics converter, inverters are a known source of harmonic emissions. Using a combination of large-scale field measurements, laboratory evaluations of inverter performance, and power system modelling, this study applies an empirical data-driven approach to investigate the impact of small-scale solar PV inverters on LV harmonic distortion magnitudes. This multi-facetted approach, involving field data analysis, laboratory assessments of inverter performance, and power system simulation to evaluate the impact of small-scale DER on harmonic distortion in LV networks, is novel in comparison to other studies, which only utilise one or two of the analysis methods of simulation, laboratory evaluation, or analysis of field measurements but not all three. The analysis of field measurement data collected over the past decade does not indicate any significant changes in harmonic distortion magnitudes that can be attributed to the increasing penetration of DERs. Power system modelling, which incorporates data obtained from laboratory inverter performance evaluations, indicates that, even at very high levels of penetration, the harmonic current emissions from solar PV inverters are only sufficient to add modest levels of harmonic distortion to LV networks, a 0.25% increase in THD for 40% penetration and a 0.62% increase in THD for 100% penetration, providing an explanation for the findings of the field data analysis.