During the shutdown of a gas turbine, natural convection flows occur inside of the engine casing. These natural convection flows cause the top of the engine casing to cool more slowly than the bottom of the casing. This non-uniform cooling can cause the casing to distort, known as “cat-back” distortion. This distortion leads to reduced tip and seal clearances, which can cause rubbing and binding. In this study, two different methods for reducing the non-uniform casing heat transfer in an industrial gas turbine during shutdown were investigated. A baseline case with no active method for reducing the casing heat transfer was compared with purge and flow extraction methods. It was found that the new proposed extraction method improved the uniformity of the casing heat transfer during the initial shutdown period.

2 February 2019
Verified
Book Chapter
Closed access
PDF file
APAndrew Pilkington
Andrew Pilkington
BRB. Rosic
B. Rosic

28 August 2020 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
APAndrew Pilkington
Andrew Pilkington
BRBudimir Rosic
Budimir Rosic
KTKoichi Tanimoto
Koichi Tanimoto
SHShigenari Horie
Shigenari Horie

APAndrew Pilkington
Andrew Pilkington
VGVinod Gopalkrishna
Vinod Gopalkrishna
CBChristopher Barnes
Christopher Barnes
LLLeo Lewis
Leo Lewis
MBMarko Bacic
Marko Bacic
An investigation was conducted into the effectiveness of heat shields in an aero-engine compressor casing to slow down thermal time constants. The investigation used a combination of experimental measurements from a full-size compressor casing rig, combined with numerical analysis using CFD and thermal modelling. Experiments were performed on a compressor casing both with and without heat shielding in order to determine the heat shield effectiveness. Temperature measurements were taken throughout the casing in order to determine the thermal time constants. The experimental data was then used to validate a thermal model and CFD simulations of the compressor casing. The modelling allowed the heat transfer coefficients in the compressor casing to be determined from the experimentally measured time constants. It was found that the heat shields gave an increase in thermal time constant at each measured location. With a doubling in the time constant at some locations compared to the unshielded case. It was also found that the heat shields need to be fully sealed, as leakage flows significantly reduce their effectiveness.