Egidijus Auksorius

Dr. Egidijus Auksorius


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2008 in Optics Letters
Verified
Journal Article
Closed access
PDF file
EAEgidijus Auksorius
Egidijus Auksorius
BBBosanta R. Boruah
Bosanta R. Boruah
CDChristopher Dunsby
Christopher Dunsby
PLPeter M. P. Lanigan
Peter M. P. Lanigan
GKGordon Kennedy
Gordon Kennedy
PFPaul M. W. French
Paul M. W. French
We demonstrate stimulated emission depletion (STED) microscopy implemented in a laser scanning confocal microscope using excitation light derived from supercontinuum generation in a microstructured optical fiber. Images with resolution improvement beyond the far-field diffraction limit in both the lateral and axial directions were acquired by scanning overlapped excitation and depletion beams in two dimensions using the flying spot scanner of a commercially available laser scanning confocal microscope. The spatial properties of the depletion beam were controlled holographically using a programmable spatial light modulator, which can rapidly change between different STED imaging modes and also compensate for aberrations in the optical path. STED fluorescence lifetime imaging microscopy is demonstrated through the use of time-correlated single photon counting.

26 June 2006 in Journal of Cell Biology
Verified
Journal Article
Open access
BTBebhinn Treanor
Bebhinn Treanor
PLPeter M.P. Lanigan
Peter M.P. Lanigan
SKSunil Kumar
Sunil Kumar
CDChris Dunsby
Chris Dunsby
IMIan Munro
Ian Munro
DDDaniel M. Davis
Daniel M. Davis
We report the supramolecular organization of killer Ig–like receptor (KIR) phosphorylation using a technique applicable to imaging phosphorylation of any green fluorescent protein–tagged receptor at an intercellular contact or immune synapse. Specifically, we use fluorescence lifetime imaging (FLIM) to report Förster resonance energy transfer (FRET) between GFP-tagged KIR2DL1 and a Cy3-tagged generic anti-phosphotyrosine monoclonal antibody. Visualization of KIR phosphorylation in natural killer (NK) cells contacting target cells expressing cognate major histocompatibility complex class I proteins revealed that inhibitory signaling is spatially restricted to the immune synapse. This explains how NK cells respond appropriately when simultaneously surveying susceptible and resistant target cells. More surprising, phosphorylated KIR was confined to microclusters within the aggregate of KIR, contrary to an expected homogeneous distribution of KIR signaling across the immune synapse. Also, yellow fluorescent protein–tagged Lck, a kinase important for KIR phosphorylation, accumulated in a multifocal distribution at inhibitory synapses. Spatial confinement of receptor phosphorylation within the immune synapse may be critical to how activating and inhibitory signals are integrated in NK cells.

30 April 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
EAEgidijus Auksorius
Egidijus Auksorius
Dawid BoryckiDawid Borycki
Dawid Borycki
PSPatrycjusz Stremplewski
Patrycjusz Stremplewski
KLKamil Liżewski
Kamil Liżewski
STSlawomir Tomczewski
Slawomir Tomczewski
MWMaciej Wojtkowski
Maciej Wojtkowski
Corneal evaluation in ophthalmology necessitates cellular-resolution and fast imaging techniques that allow for accurate diagnoses. Currently, the fastest volumetric imaging technique is Fourier-domain full-field optical coherence tomography (FD-FF-OCT), which uses a fast camera and a rapidly tunable laser source. Here, we demonstrate high-resolution, high-speed, non-contact corneal volumetric imaging in vivo with FD-FF-OCT that can acquire a single 3D volume with a voxel rate of 7.8 GHz. The spatial coherence of the laser source was suppressed to prevent it from focusing on a spot on the retina, and therefore, exceeding the maximum permissible exposure (MPE). The inherently volumetric nature of FD-FF-OCT data enabled flattening of curved corneal layers. The acquired FD-FF-OCT images revealed corneal cellular structures, such as epithelium, stroma and endothelium, as well as subbasal and mid-stromal nerves.

7 May 2019 in Optica
Verified
Journal Article
Closed access
PDF file
PSPatrycjusz Stremplewski
Patrycjusz Stremplewski
EAEgidijus Auksorius
Egidijus Auksorius
PWPaweł Wnuk
Paweł Wnuk
ŁKŁukasz Kozoń
Łukasz Kozoń
PGPiotr Garstecki
Piotr Garstecki
MWMaciej Wojtkowski
Maciej Wojtkowski
Cellular resolution imaging of biological structures has always been a challenge due to strong scattering that limits the achievable transverse resolution or imaging penetration depth. Recently, a major advancement toward high-resolution and volumetric imaging was achieved by implementing a parallel detection (i.e., full field) into Fourier-domain optical coherence tomography. The drawback of using parallel detection is that scattered light can travel laterally and get mapped improperly at a camera creating optical crosstalk, which severely impairs the interpretation of subcellular images and limits its use in medical diagnostics. In this work, we demonstrate for what we believe is the first time how to efficiently reduce crosstalk and enable microscopic quality volumetric reconstructions of the scattering tissue-like human skin in vivo, all within less than a half of a second. To minimize crosstalk, we implemented a very fast deformable membrane that introduces random phase illumination. Additionally, the sample is illuminated under variable angles to reduce the contrast of speckles by incoherent summation of the crosstalk-free volumes. Introducing crosstalk and speckle-free OCT will advance imaging prospects closer to the ideal of a noninvasive optical biopsy.

20 November 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
EAEgidijus Auksorius
Egidijus Auksorius
Dawid BoryckiDawid Borycki
Dawid Borycki
MWMaciej Wojtkowski
Maciej Wojtkowski
Fourier-domain full-field optical coherence tomography (FD-FF-OCT) is currently the fastest volumetric imaging technique that is able to generate a single 3-D volume of retina in less than 9 ms, corresponding to a voxel rate of 7.8 GHz. FD-FF-OCT is based on a fast camera, a rapidly tunable laser source, and Fourier-domain signal detection. However, crosstalk appearing due to multiply scattered light corrupts images with the speckle pattern, and therefore, lowers image quality. Here, for the first time, we report on a system that can acquire essentially crosstalk-free volumes of the retina by using a fast deformable membrane. It enables the visualization of choroids and a clear delineation of the retinal layers that is not possible with conventional FD-FF-OCT.

21 November 2007 in Optics Letters
Verified
Journal Article
Closed access
PDF file
DODylan M. Owen
Dylan M. Owen
EAEgidijus Auksorius
Egidijus Auksorius
HMHugh B. Manning
Hugh B. Manning
CTClifford B. Talbot
Clifford B. Talbot
PBPieter De Beule
Pieter De Beule
PFPaul M. W. French
Paul M. W. French
We present a time-gated, optically sectioned, hyperspectral fluorescence lifetime imaging (FLIM) microscope incorporating a tunable supercontinuum excitation source extending into the UV. The system is capable of resolving the excitation spectrum, emission spectrum, and fluorescence decays in an optically sectioned image.