Luheng Wang

Dr. Luheng Wang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
LWLuheng Wang
Luheng Wang
CXChuanguo Xu
Chuanguo Xu
YLYanling Li
Yanling Li

30 October 2015 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
LWLuheng Wang
Luheng Wang
To develop a stretchable eddy current noncontact gap sensor, the metal coil is replaced by a spiral element based on conductive polymer composite (i.e., composite spiral element). The current in the composite spiral element forms a vortex flow. The eddy current effect occurs when a metal object approaches the composite spiral element carried with alternating current. The experimental data show that the impedance of the composite spiral element changes regularly with the gap between the composite spiral element and the metal object. The test results verify the feasibility of using a composite spiral element as a stretchable eddy current noncontact gap sensor.

13 February 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LWLuheng Wang
Luheng Wang
DLDandan Lv
Dandan Lv
FWFei Wang
Fei Wang
To develop the differential pressure sensor made of carbon nanotube-filled silicone rubber composites with a simplified structure, an electrode-shared differential configuration is designed. The configuration includes the top and bottom sandwich layers. The top sandwich layer is composed of the top film, the intermediate film, and the composite film with low carbon nanotube content between them. The bottom sandwich layer is composed of the intermediate film, the bottom film, and the composite film with high carbon nanotube content between them. The electrode in the intermediate film is shared by the top and bottom sandwich layers, which can make the sensor probe more concise. The electrical resistance of the composite film with high/low carbon nanotube content increases/decreases with the increase of the pressure, and increases with the increase of the temperature. The top and bottom sandwich layers are connected to the neighboring arms of an electrical bridge to construct a differential system. The experiments verify the feasibility of using the electrode-shared configuration to construct the differential piezoresistive sensor made of the composite to decrease the temperature-induced drift and increase the sensitivity.

8 September 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LWLuheng Wang
Luheng Wang
The existing piezoresistive sensor array adopts the classical configuration called “unconnected structure”, in which the piezoresistive materials in the subelements are separated with each other. Consequently, the sensor array cannot detect the pressure applied on the region among the sub elements (i.e., blind area). To eliminate the blind area, the traditional method is to use more subelements, leading to the increase of the number of the electrodes which complicates the sensor probe. To overcome the limitation, a connected structure, in which a whole piezoresistive sheet is used in all subelements, is designed. The pressure applied on any region of the connected structure can cause the changes in the resistances of the subelements. Therefore, the region bearing pressure can be located and the pressure value can be obtained without adding electrodes. The piezoresistive sensor array made of conductive polymer composite is used as an example. The experiments show that the pressure position can be evaluated, and the pressure measurement error is less than 30 kPa within the range from 0 to 0.4 MPa. The results indicate that the usage of the connected structure can eliminate the blind area by using less electrodes than the traditional method.

25 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LWLuheng Wang
Luheng Wang
In order to solve the difficult problem of simultaneous measurement of the temperature and the noncontact gap, the experiments on the temperature sensing properties and the properties of noncontact gap measurement of the coil-shaped conductive polymer composite are investigated. The experimental data show that: 1) the impedance amplitude/angle of the coil-shaped composite decreases/increases with the increase in the temperature under the same noncontact gap and the impedance amplitude/angle decreases/increases with the increase of the noncontact gap under the same temperature and 2) the electrical resistance increases with the increase in temperature and does not change with the change in the contactless gap. Based on the above results, a strategy for simultaneous measurement of temperature and noncontact gap is proposed as follows: 1) based on the resistance change of the coil-shaped composite, the temperature change and also the impedance change induced by the temperature can be obtained and 2) based on the total impedance change and the impedance change induced by the temperature, the impedance change induced by the noncontact gap can be obtained to realize the contactless gap measurement. The above results not only confirm the feasibility of using the coil-shaped composite for temperature measurement but also provisionally verify the possibility of measuring temperature and noncontact gap simultaneously.

8 September 2024 in Measurement
Verified
Journal Article
Closed access
LWLuheng Wang
Luheng Wang
ZHZhineng Hu
Zhineng Hu
WSWenju Shui
Wenju Shui
FWFei Wu
Fei Wu