Mohammedreza Sefidroodi

Dr. Mohammedreza Sefidroodi

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMohammedreza Sefidroodi
Mohammedreza Sefidroodi
ISInleel Lundgård Shino
Inleel Lundgård Shino
SVStratos Vassis
Stratos Vassis
KHKaren Eich Hammer
Karen Eich Hammer
KKKasper Dahl Kristensen
Kasper Dahl Kristensen
JBJytte Buhl
Jytte Buhl
Continuous advancements in technology have made it possible to integrate clear aligner therapy (CAT) with orthognathic surgery. This case report presents a novel, individually-planned workflow, combining CAT with a surgery-first orthognathic approach (SFOA) in collaborating with engineers for an in-house production of surgical guides and customized titanium plates. The patient was evaluated subjectively, using the Oral Health-Related Quality of Life-14 (OHIP-14) questionnaire and Orthognathic Quality of Life questionnaire (OQLQ), and objectively with the Peer Assessment Rating (PAR) index. The patient displayed the planned occlusal relationship with no report of discomfort in the temporomandibular joint (TMJ) or post-surgical complications. The surgical and occlusal outcomes have remained consistent and stable after debonding. A decreased score was reported in both questionnaires and the PAR after treatment, thereby indicating improvements in both subjective and objective evaluations. This case report demonstrates that with proper individual planning, satisfactory subjective and objective outcomes can be achieved when combining SFOA with CAT.

2 May 2025 in The Korean Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
SVStratos Vassis
Stratos Vassis
DKDimitra Karamalaki
Dimitra Karamalaki
JLJason Liu
Jason Liu
BNBeatrice Nöldeke
Beatrice Nöldeke
MSMohammedreza Sefidroodi
Mohammedreza Sefidroodi
PSPeter Stoustrup
Peter Stoustrup
Stratos Vassis, Dimitra Karamalaki, Jason Liu, Beatrice Noeldeke, Mohammedreza Sefidroodi, Sukeshana Srivastav, Julian Woolley, Peter Stoustrup. Korean J Orthod 2025;55:349-54. https://doi.org/10.4041/kjod25.019

1 April 2024 in AJO-DO Clinical Companion
Verified
Journal Article
Open access
MSMohammedreza Sefidroodi
Mohammedreza Sefidroodi
ISInleel Lundgård Shino
Inleel Lundgård Shino
SVStratos Vassis
Stratos Vassis
KKKasper Dahl Kristensen
Kasper Dahl Kristensen
JBJytte Buhl
Jytte Buhl
TPThomas Klit Pedersen
Thomas Klit Pedersen

27 April 2024 in Research Square
Verified
Preprint
Open access
PDF file
ISInleel Lundgård Shino
Inleel Lundgård Shino
MSMohammedreza Sefidroodi
Mohammedreza Sefidroodi
SVStratos Vassis
Stratos Vassis
JBJytte Buhl
Jytte Buhl
AJAnders Mølgaard Jakobsen
Anders Mølgaard Jakobsen
SNSven Erik Nørholt
Sven Erik Nørholt
Aim of the study: This article introduces an in-house workflow implementing patient-specific surgical cutting guides and spacers combined with pre-adapted osteosynthesis in two Surgery First Orthognathic Approach (SFOA) scenarios. Background: The integration of three-dimensional virtual surgical planning (VSP) in combination with computer aided design and computer aided manufacturing (CAD/CAM) has advanced the field of orthognathic surgery. With the use of surgical guides and patient specific implants (PSI) the accuracy of the surgical outcome could potentially increase. While PSI approaches offer advantages, commercial PSIs are characterized by a prolonged turnaround time and high costs.These drawbacks linked with commercial PSIs might restrict their utilization and acceptance. Technical note: The VSP was completed in Dolphin Imaging software. 3-Matic software was used to design the cutting guides and spacers. The anterior spacers where specifically designed to utilize the wedge-technique during positioning of the anterior segment in segmented Le Fort I osteotomy. The surgical guides and spacers were manufactured in Form 3B 3D printer with BioMed Clear V1 Resin with 0.100 mm layer thickness. Titanium plates 2.0 from Biomet were customized based on a 3D-model of the planned postsurgical outcome based on the VSP. Conclusion: The in-house methodology for developing and employing personalized surgical guides, spacers and pre-adapted titanium plates offers a viable workflow for SFOA, with the potential to enhance the reliability and precision of maxillary repositioning.