Lixin Yin

Dr. Lixin Yin

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2026 in BMC Anesthesiology
Verified
Journal Article
Open access
SWShaonan Wang
Shaonan Wang
XZXiaoxi Zhang
Xiaoxi Zhang
LYLixin Yin
Lixin Yin

14 November 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XZXiaoxi Zhang
Xiaoxi Zhang
SWShaonan Wang
Shaonan Wang
GCGiselle Chan
Giselle Chan
LYLixin Yin
Lixin Yin
Clinical deployment of acute kidney injury (AKI) AI models depends on whether labels, predictors, missingness, and calibration remain stable across electronic health record (EHR) systems. To develop an AI-ready data passport and transportability stress-test framework for creatinine-based AKI prediction using MIMIC-IV v3.1 and eICU-CRD v2.0. We performed a retrospective secondary analysis of adult ICU stays. Predictions were generated at approximately 24 h after ICU admission using information observed during the first 24 h; this was not an admission-time prediction protocol. The primary outcome was a post-24-hour day-7 serum-creatinine-based operational endpoint, requiring first-24-hour creatinine and post-24-hour follow-up creatinine through day 7. Predictors included age, sex, first-24-hour renal and electrolyte laboratories, missingness indicators, and first-24-hour creatinine count. The endpoint was not intended to represent full KDIGO staging or incident AKI at ICU admission. We assessed endpoint computability and laboratory coverage, then trained L2-regularized logistic regression models in each database and externally validated them bidirectionally. Evaluation emphasized discrimination, Brier score, calibration, and measurement-density failure modes. The feasibility audit included 94,458 MIMIC-IV and 200,234 eICU adult ICU stays. First-24-hour creatinine coverage was 96.8% and 84.6%, respectively; the primary post-24-hour day-7 endpoint was computable in 89.2% and 65.6%. The modeling cohorts included 84,237 stays from 58,782 MIMIC-IV patients and 131,429 stays from 102,013 eICU patients, with primary endpoint event rates of 26.9% and 18.5%. Internal AUROC was 0.732 in MIMIC-IV and 0.723 in eICU. External AUROC was 0.703 for MIMIC-IV to eICU and 0.722 for eICU to MIMIC-IV, with confidence intervals reported in the main table. Calibration shifted directionally: MIMIC-IV to eICU overpredicted risk, whereas eICU to MIMIC-IV underpredicted higher-risk strata. Prediction of a post-24-hour day-7 creatinine-rise operational endpoint was feasible across MIMIC-IV and eICU, but endpoint computability, laboratory coverage, measurement density, and calibration shift differed substantially. The endpoint was not full KDIGO staging or proof of incident AKI at ICU entry, and the retrospective results do not establish clinical deployment readiness. Renal-risk AI should include an EHR data passport and calibration-focused algorithmovigilance before transport or deployment claims.

22 August 2026 in Research Square
Verified
Preprint
Open access
PDF file
XZXiaoqiang Zhu
Xiaoqiang Zhu
XCXiangming Cao
Xiangming Cao
SWShancheng Wang
Shancheng Wang
XZXiaorong Zhu
Xiaorong Zhu
LYLixin Yin
Lixin Yin
Background Artificial intelligence (AI) in hospitals is moving from retrospective model development toward information processing embedded in electronic health record (EHR)-mediated workflows. Evidence spans documentation, retrieval, prediction, referral, human factors, and governance, so workflow feasibility must be distinguished from patient-level benefit. Objective To map real-world integration of AI-enabled information processing into hospital EHR workflows and examine how reported implementation requirements align with publicly documented AI-readiness conditions in China. Methods The protocol specifies a JBI scoping review with PRISMA-ScR/PRISMA-S reporting. The executed route is PubMed/PMC plus targeted public sources. Two deterministic AI-agent screens and conservative adjudication classified 2,296 journal/article records as 810 include, 667 uncertain and 819 provisional exclude; all remain flagged for human verification. This AI-only route is not a completed human PRISMA-ScR screen. Evidence was organized by EHR lifecycle and M0–M5 maturity. MMAT 2018 is planned after eligibility is locked; heterogeneity precluded meta-analysis. Results The AI-agent route identified a conditional candidate pool centered on documentation, retrieval, screening/referral and risk communication (810 include; 667 unresolved for full text). Gains were mainly process-level; risks included calibration, alert burden, role-specific acceptance and template-related quality loss. Chinese public captures suggest layered EHR readiness, but three NHC pages returned HTTP 412 and remain conditional. Conclusions The AI-only evidence map suggests feasible AI-enabled EHR integration in selected workflows, but safe value depends on calibration, interoperability, human verification, change control, and monitoring. Evidence is stronger for workflow feasibility than patient-level effectiveness; final conclusions require author-accountable human screening, full-text extraction and source verification.

19 December 2025 in The Heart Surgery Forum
Verified
Journal Article
Open access
PDF file
SWShancheng Wang
Shancheng Wang
LYLei Yang
Lei Yang
YZYu Zhang
Yu Zhang
YZYongqiang Zheng
Yongqiang Zheng
DWDing Wang
Ding Wang
WXWei Xing
Wei Xing
Background: Patients with ST-segment elevation myocardial infarction (STEMI) remain at risk for major adverse cardiovascular events (MACE) following percutaneous coronary intervention (PCI). Current risk scores lack detailed myocardial tissue characteristics from cardiac magnetic resonance (CMR) imaging for long-term prediction. The aim of this study was therefore to develop and validate a prognostic nomogram that integrates CMR and clinical data to better predict 1- to 3-year MACE in new-onset STEMI patients post-PCI. Methods: This retrospective study included patients who underwent PCI for new-onset STEMI between January 2020 and June 2022. Data from two centers were pooled. The combined cohort was then randomly divided into a derivation cohort (n = 107) for model development and an internal validation cohort (n = 46) for performance assessment. Univariate and multivariate Cox proportional hazards regression analyses were performed to identify independent risk factors and construct a nomogram. The predictive performance of this nomogram was assessed using C-indexes, time-dependent Receiver Operating Characteristic (ROC) curves, calibration curves, and decision curve analysis (DCA). Results: A total of 107 new-onset STEMI patients were included in the derivation cohort and 46 in the internal validation cohort. Cumulative MACE incidence rates at 1-, 2-, and 3- years were 20.6%, 34.6%, and 44.9% in the derivation cohort, and 21.7%, 34.8%, and 50.0% in the internal validation cohort, respectively. The final nomogram incorporated six independent predictors derived from both clinical and CMR data: the Gensini Score (hazard ratio [HR]: 1.012, 95% confidence interval [CI]: 1.003–1.020, p = 0.006), albumin (HR: 0.849, 95% CI: 0.769–0.938, p = 0.001), low-density lipoprotein cholesterol (LDL-C; HR: 1.377, 95% CI: 1.037–1.828, p = 0.027), Left Ventricular Ejection Fraction (LVEF; HR: 0.890, 95% CI: 0.833–0.951, p = 0.001), Left Ventricular End-Diastolic Volume (LVEDV; HR: 1.014, 95% CI: 1.003–1.025, p = 0.015), and the mean of Left Ventricular Wall Motion (LVWM; HR: 0.464, 95% CI: 0.288–0.747, p = 0.002), derived from both clinical and CMR data. The nomogram demonstrated good discriminatory ability in the derivation cohort (C-index: 0.803; 95% CI: 0.739–0.867) and moderate discrimination in the internal validation cohort (C-index: 0.693; 95% CI: 0.570–0.816). Calibration plots indicated good agreement between the predicted and observed MACE probabilities in both cohorts. DCA confirmed the potential clinical utility of the nomogram. Conclusion: Our validated prognostic nomogram, integrates CMR parameters and clinical data. It effectively discriminates high- and low-risk new-onset STEMI patients for 1-, 2-, and 3-year MACE following PCI. This tool may assist with risk stratification and in guiding personalized therapeutic strategies.