Vikas Vikas

Dr. Vikas Vikas

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2025 in Antioxidants
Verified
Journal Article
Open access
PDF file
VVVikas Vikas
Vikas Vikas
Weibing YangWeibing Yang
Weibing Yang
BWBrian Wilson
Brian Wilson
TZTimothy C. Zhu
Timothy C. Zhu
RHRobert H Hadfield
Robert H Hadfield
The effectiveness of photodynamic therapy (PDT) for cancer treatment relies on the generation of cytotoxic singlet oxygen (1O2) in type II PDT. Hence, monitoring of 1O2 generation during PDT enables optimal treatment delivery to the tumor target with reduced off-target effects. Direct 1O2 observation by measuring its luminescence at 1270 nm remains challenging due to the very weak signal. This study presents 1O2 luminescence measurements using a time-resolved singlet oxygen luminescence detection system (TSOLD) applied to protoporphyrin IX (PpIX) in different solvents (ethanol and acetone) and biological media (bovine serum albumin and agarose-based solid phantom). The compact experimental setup includes a nanosecond diode laser with a function generator, a cuvette with photosensitizer solution, optical filtering and mirrors, an InGaAs single-photon avalanche diode detector, and time-tagger electronics. Increasing the concentration of PpIX in these media from 1 to 10 µg/g resulted in a 3–5 × increase in the 1O2 luminescence signal. Furthermore, increasing light scattering in the sample using Intralipid from 0.1 to 1% led to a decrease in the 1O2 luminescence signal and lifetime. These results confirm the marked effect of the microenvironment on the 1O2 signal and, hence, on the photodynamic efficacy.

28 November 2024 in Antioxidants
Verified
Journal Article
Open access
PDF file
Weibing YangWeibing Yang
Weibing Yang
MJMadelyn Johnson
Madelyn Johnson
BLBaozhu Lu
Baozhu Lu
DSDennis Sourvanos
Dennis Sourvanos
HSHongjing Sun
Hongjing Sun
TZTimothy C. Zhu
Timothy C. Zhu
The direct detection of singlet-state oxygen (1O2) constitutes the holy grail dosimetric method for type-II photodynamic therapy (PDT), a goal that can be quantified using multispectral singlet oxygen near-infrared luminescence dosimetry (MSOLD). The optical properties of tissues, specifically their scattering and absorption coefficients, play a crucial role in determining how the treatment and luminescence light are attenuated. Variations in these properties can significantly impact the spatial distribution of the treatment light and hence the generation of singlet oxygen and the detection of singlet oxygen luminescence signals. In this study, we investigated the impact of varying optical properties on the detection of 1O2 luminescence signals during Photofrin-mediated PDT in tissue-mimicking phantoms. For comparison, we also conducted Monte Carlo (MC) simulations under the same conditions. The experimental and simulations are substantially equivalent. This study advances the understanding of MSOLD during PDT.

1 December 2025 in Journal of Biomedical Optics
Verified
Journal Article
Open access
Weibing YangWeibing Yang
Weibing Yang
BLBaozhu Lu
Baozhu Lu
MJMadelyn Johnson
Madelyn Johnson
DSDennis Sourvanos
Dennis Sourvanos
HSHongjing Sun
Hongjing Sun
TZTimothy C. Zhu
Timothy C. Zhu
SignificanceDirect detection of singlet-state oxygen (O12) is a critical objective in Type II photodynamic therapy (PDT) due to its pivotal role in mediating therapeutic effects. Although multispectral singlet oxygen dosimetry (MSOLD) has demonstrated the capability to detect O12 luminescence both in vitro and in vivo, there remains no standardized method for accurately quantifying reactive singlet oxygen, [O2]rx1, based on these measured signals. By contrast, the singlet oxygen explicit dosimetry (SOED) model offers a robust framework for calculating [O2]rx1. Demonstrating that O12 luminescence obtained through MSOLD can reliably quantify [O2]rx1, as achieved by the SOED model, is essential for advancing the accuracy and applicability of PDT dosimetry.AimWe aim to evaluate the accuracy and reliability of MSOLD in quantifying O12 concentrations from measured O12 luminescence in benzoporphyrin derivative (BPD)-mediated PDT. The performance of MSOLD is assessed by comparing its results with those derived from the SOED model.ApproachA continuous-wave 690 nm laser was used to excite a nanoparticle formulation of BPD, tradename Visudyne® in methanol at varying concentrations (2 to 6 mg/L). The singlet oxygen luminescence was measured using an InGaAs spectrometer and analyzed using a singular value decomposition algorithm. Near-infrared singlet oxygen emission at ∼1270 nm was extracted as O12 luminescence. Real-time singlet oxygen spectra were collected over 900 s using a 1.5 mm diameter fiber optic. Ground-state oxygen concentration was measured with a commercial oxygen probe, photosensitizer concentration was determined with a custom-made contact probe, and photon fluence rate was assessed with an isotropic detector. [O2]rx1 was then calculated based on the SOED model.ResultsThe extracted singlet oxygen (O12) luminescence exhibited clear concentration-dependent trends, with higher BPD concentrations producing stronger O12 luminescence. Over time, the O12 luminescence decayed due to photosensitizer bleaching. In addition, a strong linear correlation was observed between the O12 luminescence measured via MSOLD and the reactive oxygen species (ROS) concentrations calculated using the SOED model. We also investigated the impact of tissue optical properties on singlet oxygen luminescence detection and developed correction factors to account for their variations.ConclusionsWe demonstrate that singlet oxygen (O12) detected through MSOLD can reliably quantify ROS concentrations in BPD-mediated PDT with accuracy comparable to the SOED model, which requires separate measurements of light fluence rate, photosensitizer concentration, and oxygen availability, followed by modeling to estimate the amount of reactive singlet oxygen. By contrast, MSOLD can also be a more cost-effective, simpler, and faster alternative to SOED as it directly measures the singlet oxygen luminescence to quantify reactive singlet oxygen. Under appropriate correction for tissue optical properties, MSOLD presents a promising, robust, and direct dosimetry solution for clinical PDT applications.

8 January 2026 in ACS Photonics
Verified
Journal Article
Open access
VVVikas Vikas
Vikas Vikas
BLBaozhu Lu
Baozhu Lu
WYWeibing Yang
Weibing Yang
BWBrian C. Wilson
Brian C. Wilson
TZTimothy C. Zhu
Timothy C. Zhu
RHRobert H. Hadfield
Robert H. Hadfield
The efficacy of photodynamic therapy (PDT) is strongly influenced by the biodistribution of the photosensitizer and the local generation of 1O2 within tumor tissue. However, real-time in vivo monitoring of these critical parameters for clinically approved photosensitizers remain a major challenge in translational photodynamic research. We report a novel portable bifurcated fiber-coupled time-resolved singlet oxygen luminescence detection instrument combining an integrating pulsed 690 nm diode laser system. Using this instrument, 1O2 signal is estimated corresponding to the uptake kinetics of the clinical photosensitizer benzoporphyrin derivative (BPD) in tumor-bearing mice up to 3 h post injection along with pre- and post-PDT 1O2 luminescence were measured in the same mice. The measured 1O2 counts correlate with the increase in BPD accumulation in the tumor region from 15 min to 2 h post injection and then remain constant in the 2–3 h measurement period. A strong positive correlation was observed between local BPD uptake and singlet oxygen signal. The estimated lifetime of 1O2 in vivo was 0.25–0.35 μs. The TSOLD system provided consistent, noninvasive readouts of 1O2 generation in real time with minimal background interference. Control experiments using BPD-free conditions confirmed the specificity of the detected signal. This study demonstrates a novel, noninvasive optical approach for simultaneous murine in vivo quantification of photosensitizer uptake and singlet oxygen production during PDT. This portable TSOLD instrument enables dynamic monitoring of therapeutic conditions in preclinical cancer models and has potential for future adaptation to clinical settings, supporting more precise and personalized PDT planning and dosimetry.

20 April 2026 in Superconductor Science and Technology
Verified
Journal Article
Open access
NCNidhi Choudhary
Nidhi Choudhary
DMDmitry Morozov
Dmitry Morozov
DKDaniel Kuznesof
Daniel Kuznesof
CLCiaran T Lennon
Ciaran T Lennon
VVVikas Vikas
Vikas Vikas
RHRobert H Hadfield
Robert H Hadfield
The advancement of superconducting nanowire single photon detectors (known as SNSPDs or SSPDs) is intrinsically linked to breakthroughs in superconducting materials engineering. These detectors are prized for their excellent sensitivity and performance across a wide wavelength range, from UV to mid-infrared. Plasmaenhanced atomic layer deposition (ALD) is an advanced deposition technique that enables exceptional film uniformity across large wafers, making it ideal for a variety of applications. In this study, ALD NbTiN films are fabricated into SNSPDs that exhibit single-photon response from near-to mid -infrared wavelengths. A 5 nm thick NbTiN film was patterned into devices consisting of ~100 nm wide meandered nanowires, and the nanowire crosssection and composition was analysed by transmission electron microscopy (TEM). The devices were tested in a closed-cycle cryostat with a base temperature of 0.9 K. Photon detection rate and timing jitter were measured across the wavelength range 1.5 -4.4 µm under low dark count conditions, confirming single-photon sensitivity across the measured wavelength bands. This work introduces the ALD-grown films as a new platform for SNSPD detectors, achieving mid-infrared detection. The intact film quality after fabrication demonstrates the potential of ALD processes for scalable infrared detector technologies.

27 March 2026 in Biomedical Optics Express
Verified
Journal Article
Open access
VVVikas Vikas
Vikas Vikas
BLBaozhu Lu
Baozhu Lu
BWBrian C. Wilson
Brian C. Wilson
TZTimothy C. Zhu
Timothy C. Zhu
RHRobert H Hadfield
Robert H Hadfield
Singlet oxygen ( 1 O 2 ) is the primary cytotoxic agent in Type-II photodynamic therapy (PDT). Single-photon avalanche diode (SPAD)-based time-resolved singlet oxygen luminescence detection (TSOLD) systems enable direct detection of the near-infrared 1 O 2 phosphorescence (∼1270 nm) during PDT, offering a powerful tool for treatment monitoring. However, the efficiency of detection depends strongly on the acquisition parameters. Here, we present a comprehensive evaluation of a TSOLD system with 630 nm and 690 nm nanosecond pulsed diode lasers developed for in vivo PDT monitoring. The influence of acquisition time (1–300 s), SPAD dead time (5-40 µs), and temporal bin width (1–100 ns) on the fidelity of 1 O 2 lifetime measurements and signal-to-noise ratio (SNR) was quantitatively investigated. Measurements were performed using liquid phantoms containing the photosensitizers Photofrin or benzoporphyrin derivative, with acquisition time further validated in vivo in murine tumor models. The results demonstrate that both acquisition time and detector dead time significantly affect the signal vs. time histogram shape and the accuracy of the 1 O 2 and photosensitizer triplet-state lifetime measurements, while an optimal bin width minimizes photon-count noise without compromising temporal resolution. The optimized parameters enable reliable 1 O 2 lifetime extraction within 100 s from the mouse model in vivo . This systematic evaluation establishes quantitative design guidelines for compact TSOLD systems tailored to in vivo applications.