We investigated the performance of synthetic high purity monocrystalline diamond radiation detectors fabricated with TiW, Cr/Au and a novel metallization technique utilising diamond-like carbon tunnelling junction and Pt/Au as electrical contacts. The investigation was carried out under irradiation with 60Co gamma-rays, 90Sr electrons and 241Am alpha-particles. The experimental results with respect to I-V dark current levels, irradiation photocurrent, signal-to-noise ratio and time response have been compared and discussed. Results show an ohmic behaviour of the DLC/Pt/Au contact, a charge collection efficiency of 100% at an applied electric field of 0.377 V/ mum for all electrical contacts (under 90Sr electrons irradiation) at a correspondent dark current value of less than a picoAmpere. The single crystal CVD DLC/Pt/Au diamond radiation detector reported here shows spectroscopic energy resolution of 1.1% at an applied voltage of +450 volts (0.9 V/mum) under 5.5 MeV alpha particle irradiation. No dasiamemorypsila or dasiapumpingpsila effect was observed for the DLC/Pt/Au contact at positive bias; the signal was also stable (fluctuations below 0.5%) and reproducible under 60Co irradiation, with a signal-to-noise ratio > 10000:1 and a linearity in the dose rate response.
The new generation of synthetic diamonds grown as a CVD single crystal on a high pressure high temperature substrate offers a wide range of applications. In particular, because of the near tissue equivalence and its small size (good spatial resolution), CVD single crystal diamond finds applicability in radiotherapy as a dosemeter of ionizing radiation. In this paper we report the electrical and dosimetric properties of a new diamond detector which was fabricated at IFJ based on a single crystal detector-grade CVD diamond provided with a novel contact metallization. Diamond properties were assessed at IFJ using a Theratron 680E therapeutic 60Co gamma rays unit and at COOK with 6 and 18 MV x-rays Varian Clinac CL2300 C/D accelerator. The new dosemeter showed high electric and dosimetric performances: low value of dark current, high current at the level of some nanoamperes during irradiation, very fast dynamic response with a rise time amounting to parts of a second, good stability and repeatability of the current and linearity of the detector signal at different dose and dose rate levels typically applied in radiotherapy. The results confirm the potential applicability of diamond material as a dosemeter for applications in radiotherapy.