1 December 2012 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
24 November 2021 in Physical Review Letters
We investigate the angular momentum removal from fission fragments (FFs) through neutron and -ray emission, finding that about half the neutrons are emitted with angular momenta and that the change in angular momentum after the emission of neutrons and statistical rays is significant, contradicting usual assumptions. Per fission event, in our simulations, the neutron and statistical -ray emissions change the spin of the fragment by , with a large standard deviation comparable to the average value. Such wide angular momentum removal distributions can hide any underlying correlations in the fission fragment initial spin values. Within our model, we reproduce data on spin measurements from discrete transitions after neutron emissions, especially in the case of light FFs. The agreement further improves for the heavy fragments if one removes from the analysis the events that would produce isomeric states. Finally, we show that while in our model the initial FF spins do not follow a sawtoothlike behavior observed in recent measurements, the average FF spin computed after neutron and statistical emissions exhibits a shape that resembles a sawtooth. This suggests that the average FF spin measured after statistical emissions is not necessarily connected with the scission mechanism as previously implied.
16 June 2020 in IEEE Access
The outbreak of the novel coronavirus disease, COVID-19 turned into a global pandemic in March 2020. During these unprecedented times, there is an increased demand in medical and personal protective equipment (PPE). Since the supplies may take a long time to meet the global demand, reusing PPEs will help health care workers in their response to the COVID-19 pandemic. To ensure the safety and well-being of the medical first responders, PPE needs to be sterilized before reuse. In this review, we examine various sterilization techniques that can be used to sterilize PPEs and point out its limitations. The objective is to provide a foundation of knowledge incorporating different sterilization techniques that allow hospitals and clinics to pick the most suitable technique for sterilization of a particular PPE.
13 September 2019 in IEEE Transactions on Nuclear Science
We propose a hierarchical Bayesian model and state-of-art Monte Carlo sampling method to solve the unfolding problem, i.e., to estimate the spectrum of an unknown neutron source from the data detected by an organic scintillator. Inferring neutron spectra is important for several applications, including nonproliferation and nuclear security, as it allows the discrimination of fission sources in special nuclear material (SNM) from other types of neutron sources based on the differences of the emitted neutron spectra. Organic scintillators interact with neutrons mostly via elastic scattering on hydrogen nuclei and therefore partially retain neutron energy information. Consequently, the neutron spectrum can be derived through deconvolution of the measured light output spectrum and the response functions of the scintillator to monoenergetic neutrons. The proposed approach is compared to three existing methods using simulated data to enable controlled benchmarks. We consider three sets of detector responses. One set corresponds to a 2.5 MeV monoenergetic neutron source and two sets are associated with (energy-wise) continuous neutron sources (252Cf and 241AmBe). Our results show that the proposed method has similar or better unfolding performance compared to other iterative or Tikhonov regularization-based approaches in terms of accuracy and robustness against limited detection events, while requiring less user supervision. The proposed method also provides a posteriori confidence measures, which offers additional information regarding the uncertainty of the measurements and the extracted information.
11 June 2013 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
24 July 2023 in IEEE Access
Artificial neural networks (ANNs) have shown several benefits over the traditional classification methods for radiation detector data, such as greater accuracy and the ability to classify neutron-photon combinations from piled-up events. These capabilities are of particular interest in applications involving intense radiation environments where large instantaneous detector count rates can lead to many piled-up events and subsequent information loss. The recovery of individual radiation detector pulses from piled-up data can improve the efficiency of classification systems, making them more attractive for field applications. This work extends the use of ANN systems with piled-up recovery to the real-time domain, with a focus on hardware implementation. The ANN system is implemented on a Virtex-5 XC5VSX95T FPGA which collects pulse data at 250MHz and then processes and classifies pulses in the pipelined ANN at lower frequencies. The system’s performance is demonstrated by classifying pulses in real-time in a variety of scenarios including passive background, passive plutonium-beryllium (PuBe), and active PuBe. The results show that the system can provide accurate classifications in real-time while displaying the results clearly to the user. The system is shown to be capable of classifying pulses at a maximum rate of 1.11×10 6 pulses per second, a maximum latency of 7.7μs, and an overall accuracy of 98.2%.