Although it is estimated that more than one million Americans have celiac disease (CD), it remains challenging to diagnose. CD, an autoimmune and inflammatory response following the ingestion of gluten-containing foods, has symptoms overlapping with other diseases and requires invasive diagnostics. The gold standard for CD diagnosis involves serologic blood tests followed by invasive confirmatory biopsies. Here, we propose a less invasive method using an electrochemical DNA (E-DNA) biosensor for CD-specific autoantibodies (AABs) circulating in blood. In our approach, CD-specific AABs bind a synthetic neoepitope, causing a conformational change in the biosensor, as well as a change in the environment of an attached redox reporter, producing a measurable current reduction. We assessed the biosensor’s ability to detect CD-specific patient-derived AABs in physiological buffer as well as buffer supplemented with bovine serum. Our biosensor was able to detect AABs in a dose-dependent manner; increased signal change correlated with increased AAB concentration with an apparent dissociation constant of 0.09 ± 0.03 units/mL of AABs. Furthermore, we found our biosensor to be target-specific, with minimal off-target binding of multiple unrelated biomarkers. Future efforts aimed at increasing sensitivity in complex media may build upon the biosensor design presented here to further improve CD AAB detection and CD diagnostic tools.
Carrion’s disease, caused by infection with the bacterium Bartonella bacilliformis (B. bacilliformis), is effectively treated with antibiotics, but reaches fatality rates of ~90% if untreated. Current diagnostic methods are limited, insufficiently sensitive, or require laboratory technology unavailable in endemic areas. Electrochemical aptamer-based (E-AB) biosensors provide a potential solution for this unmet need, as these biosensors are portable, sensitive, and can rapidly report the detection of small molecule targets. Here, we developed an E-AB biosensor to detect Pap31, a biomarker of Carrion’s disease and an outer membrane protein in B. bacilliformis. We identified an aptamer with Pap31-specific binding affinity using a magnetic pull-down assay with magnetic bead-bound Pap31 and an aptamer library followed by electrophoretic mobility shift assays. We incorporated the Pap31-binding aptamer into a DNA oligonucleotide that changes conformation upon binding Pap31. The resultant Pap31 E-AB biosensor produced a rapid, significant, and target-specific electrical current readout in the buffer, demonstrating an apparent KD of 0.95 nM with a limit of detection of 0.1 nM, and no significant signal change when challenged with off-target proteins. This proof-of-concept Pap31 biosensor design is a first step toward the development of more rapid, sensitive, and portable diagnostic tools for detecting Carrion’s disease.