Background: There are cases of idiopathic interstitial pneumonias (IIPs) that do not meet the diagnostic criteria for connective tissue disease but have clinical features suggestive of autoimmune process. Interstitial pneumonia with autoimmune features (IPAF) was recently proposed as a research concept for these patients. Although several prospective studies on IPAF have been conducted, its clinical significance in cryptogenic organizing pneumonia (COP) remains unclear. Methods: Patients aged ≥20 years with suspected COP were prospectively enrolled between June 2018 and December 2022. Among the enrolled patients, those diagnosed with COP based on computed tomography (CT) and bronchoalveolar lavage (BAL) findings were compared between the IPAF and non-IPAF groups. Results: A total of 56 patients were enrolled in this study. Of these, 30 were diagnosed with COP and included in the analysis. Clinical and serological features were positive in two and six patients, respectively. Each feature was exclusive, and eight patients (26.7%) were diagnosed with IPAF. There were no differences between the IPAF and non-IPAF groups in terms of clinical features, including BAL findings, laboratory data, CT findings, and clinical course. During the one-year follow-up period, the frequency of COP exacerbation did not differ between the IPAF and non-IPAF groups, and no cases of systemic autoimmune disease or death occurred in either group. Conclusions: The COP characteristics of the IPAF and non-IPAF groups are similar in all aspects, and distinguishing between the two groups may be of little significance.
BACKGROUND: Time in target range (TTR) reflects the proportion of time that blood pressure (BP) stays within guideline-recommended levels. However, the distribution of home BP TTR and its association with subclinical cerebrovascular disease in community-based populations remain unclear. METHODS: We investigated annual and seasonal TTR of Internet of Things-based home BP and its association with brain lesions on magnetic resonance imaging in a community-based cohort. Home BP was measured twice daily (morning and evening). Weekly mean BP was calculated from ≥3 valid daily readings, and TTR was defined in those with ≥2 valid weeks/season as the percentage of weeks meeting guideline-based targets (systolic and diastolic BP <135 and <85 mm Hg, respectively, for participants not receiving antihypertensive medication; <125 and <75 mm Hg, respectively, for those receiving medication). Brain lesions included ≥1 magnetic resonance imaging-detected lacunar infarct, white matter hyperintensities, cerebral microbleeds, or intracranial artery stenosis. RESULTS: Among 306 participants (mean age, 56 years; 57% women), median annual TTR was 100% (interquartile range, 92.6%–100%) in participants not receiving antihypertensive medication and 1.9% (0%–19.2%) in those receiving medication. TTR tended to be lower in winter than in summer. In Poisson regression with robust variance, adjusted for demographic, lifestyle, and clinical factors, higher TTR was associated with a lower prevalence of brain lesions (prevalence ratio per 10% higher, 0.85 [95% CI, 0.79–0.91]). The association was stronger among participants not receiving antihypertensive medication (interaction P =0.047), with no heterogeneity across seasons (interaction P =0.958). CONCLUSIONS: Home BP TTR may help characterize longitudinal BP control and provide complementary information regarding cerebrovascular health.
This study evaluates the image quality and quantitative accuracy of SPECT images with pre- and post-reconstruction smoothing filters in somatostatin receptor scintigraphy using phantom data. We evaluated the spatial resolution, the contrast-to-noise ratio (CNR), and the quantitative accuracy using a NEMA IEC body phantom filled with a 111In solution. SPECT images were obtained with a Siemens Symbia T16 SPECT/CT system. Quantitative accuracy refers to the ability to accurately estimate the radioactive concentration of 111In in the phantom from the image. SPECT reconstructions were performed using three methods: post-reconstruction Gaussian filtering (post-G), pre-reconstruction Gaussian filtering (pre-G), and pre-reconstruction Butterworth filtering (pre-B). To verify each filtering method, the cut-off frequency of the Butterworth filter and the full width at half maximum (FWHM) of the Gaussian filter were each changed to eight different settings. FWHMs were 21.2, 19.8, and 18.0 mm for post-G, pre-G, and pre-B. CNRs (37-mm sphere) were 47.2, 63.8, and 69.5. Pre-B showed a 12.0 % error rate at 0.40 cycles/cm, while post-G and pre-G showed 20.2 % and 22.0 % at 7.2-mm FWHM. Pre-B outperformed other methods for resolution, CNR, and quantitative accuracy. For 111In-pentetreotide SPECT images, image reconstruction with a Butterworth filter applied to the projection image before reconstruction was found to be superior to reconstruction with a Gaussian filter in terms of image quality and quantitative accuracy. This method can be easily implemented in routine clinical SPECT imaging workflows and has the potential to improve diagnostic confidence. The proposed method with a pre-reconstruction Butterworth filter has great potential to improve the image quality and quantitative accuracy of 111In-SPECT images.