Hiroyuki Ijima

Prof. Hiroyuki Ijima

Department of Chemical Engineering, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-Ku, Fukuoka 819-0395, Japan
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
JFJannatul Fardous
Jannatul Fardous
YOYuji Omoso
Yuji Omoso
AJAkshat Joshi
Akshat Joshi
KYKozue Yoshida
Kozue Yoshida
KPKawchar Ahmed Patwary
Kawchar Ahmed Patwary
HIHiroyuki Ijima
Hiroyuki Ijima

1 January 2023 in Smart Materials in Medicine
Verified
Journal Article
Open access
ZYZhengchao Yuan
Zhengchao Yuan
LZLixiang Zhang
Lixiang Zhang
SJShichao Jiang
Shichao Jiang
MSMuhammad Shafiq
Muhammad Shafiq
YCYoujun Cai
Youjun Cai
Xiumei MoXiumei Mo
Xiumei Mo

1 September 2019 in Journal of Bioscience and Bioengineering
Verified
Journal Article
Closed access
HIHiroyuki Ijima
Hiroyuki Ijima
SNShintaro Nakamura
Shintaro Nakamura
RBRonald Perocho Bual
Ronald Perocho Bual
KYKozue Yoshida
Kozue Yoshida

1 May 2018 in Gels
Verified
Journal Article
Open access
PDF file
HIHiroyuki Ijima
Hiroyuki Ijima
SNShintaro Nakamura
Shintaro Nakamura
Ronald Perocho BualRonald Perocho Bual
Ronald Perocho Bual
NSNana Shirakigawa
Nana Shirakigawa
STShuichi Tanoue
Shuichi Tanoue
The decellularization of organs has attracted attention as a new functional methodology for regenerative medicine based on tissue engineering. In previous work we developed an L-ECM (Extracellular Matrix) as a substrate-solubilized decellularized liver and demonstrated its effectiveness as a substrate for culturing and transplantation. Importantly, the physical properties of the substrate constitute important factors that control cell behavior. In this study, we aimed to quantify the physical properties of L-ECM and L-ECM gels. L-ECM was prepared as a liver-specific matrix substrate from solubilized decellularized porcine liver. In comparison to type I collagen, L-ECM yielded a lower elasticity and exhibited an abrupt decrease in its elastic modulus at 37 °C. Its elastic modulus increased at increased temperatures, and the storage elastic modulus value never fell below the loss modulus value. An increase in the gel concentration of L-ECM resulted in a decrease in the biodegradation rate and in an increase in mechanical strength. The reported properties of L-ECM gel (10 mg/mL) were equivalent to those of collagen gel (3 mg/mL), which is commonly used in regenerative medicine and gel cultures. Based on reported findings, the physical properties of the novel functional substrate for culturing and regenerative medicine L-ECM were quantified.

28 December 2022 in Advanced Fiber Materials
Verified
Journal Article
Closed access
PDF file
YIYasuhiro Ikegami
Yasuhiro Ikegami
MSMuhammad Shafiq
Muhammad Shafiq
SAShinichi Aishima
Shinichi Aishima
HIHiroyuki Ijima
Hiroyuki Ijima

30 May 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
MRMuhammad Rafique
Muhammad Rafique
OAOnaza Ali
Onaza Ali
MSMuhammad Shafiq
Muhammad Shafiq
MYMinghua Yao
Minghua Yao
KWKai Wang
Kai Wang
MIMasato Ikeda
Masato Ikeda
Oxygen is one of the essential requirements for cell survival, retention, and proliferation. The field of regenerative medicine and tissue engineering (TE) has realized considerable achievements for the regeneration of tissues. However, tissue regeneration still lacks the full functionality of solid organ implantations; limited cell survival and retention due to oxidative stress and hypoxia in the deeper parts of tissues remains a perpetual challenge. Especially prior to neovascularization, hypoxia is a major limiting factor, since oxygen delivery becomes crucial for cell survival throughout the tissue-engineered construct. Oxygen diffusion is generally limited in the range 100–200 μm of the thickness of a scaffold, and the cells located beyond this distance face oxygen deprivation, which ultimately leads to hypoxia. Furthermore, before achieving functional anastomosis, implanted tissues will be depleted of oxygen, resulting in hypoxia (<5% dissolved oxygen) followed by anoxic (<0.5% dissolved oxygen) microenvironments. Different types of approaches have been adopted to establish a sustained oxygen supply both in vitro and in vivo. In this review, we have summarized the recent developments in oxygen-generating and/or releasing biomaterials for enhancing cell survival in vitro, as well as for promoting soft and hard tissue repair, including skin, heart, nerve, pancreas, muscle, and bone tissues in vivo. In addition, redox-scavenging biomaterials and oxygenated scaffolds have also been highlighted. The surveyed results have shown significant promise in oxygen-producing biomaterials and oxygen carriers for enhancing cell functionality for regenerative medicine and TE applications. Taken together, this review provides a detailed overview of newer approaches and technologies for oxygen production, as well as their applications for bio-related disciplines.