The optimisation of heat exchanger is an important issue. So, the optimum size of counter flow surface condenser is found in this research work for Maral Overseas Ltd by entropy, exergy and entransy theories. In this work, effectiveness of heat exchanger, number of transfer units, entropy generation, entransy dissipation, entransy dissipation-based thermal resistance, entransy dissipation number and entransy effectiveness for hot/cold fluid sides with outlet temperatures of fluids are found for various 4L/D ratios. And then the optimum value of 4L/D ratio is found for the surface condenser. Entransy dissipation number and entransy-based thermal resistance both must be as low as possible for proper design. It is observed that when 4L/D ratio increases then EDN, entransy dissipation-based thermal resistance, outlet temperature of hot fluid and entropy generation decrease but NTU, effectiveness and outlet temperature of cold fluid increase. This research work is concluded as when 4L/D ratio increases with one unit, EDN values decrease with 0.05–0.02, but after some time, when 4L/D ratio increases with ten units, EDN values decrease with only 0.01. Finally, the optimum condition of 4L/D ratio for surface condenser is found, which is 40. Computer software is also developed to eliminate hectic calculations and human errors for performance analyses of heat exchangers.
19 March 2019 in International Journal of Ambient Energy
In this research work, exergy and entransy analyses are done to find best operating conditions for heat exchangers. Power outputs and heat rates for coal fired thermal power plant are also calculated at different loads of plant. Mass flow rates, ambient temperature, extraction lines pressure drops and percentage increments of flow rates are chosen as variable parameters. Analyses can be done on developed PACFTPPEEC software. This work is concluded as – exergy rates for boiler and reheater increase with mass flow rates and ambient temperature; entransy dissipation number will be maximum when increment of mass flow rates of fluids are 5%; exergy/entransy dissipation rates, entransy dissipation based thermal resistances and entransy dissipation numbers decrease with extraction line pressure drop and best operating conditions for heaters were obtained at 0% pressure drop. After analyses, smooth inner surfaces for extraction lines are recommended to minimize exergy and entransy dissipation rates for heaters.
Parabolic solar collectors have been used for feed water heating process instead of extractions from steam turbines to enhance the power output and heat rate for a coal-fired thermal power plant. In this analytical work, entropy-exergy concepts have been applied on steam turbines and solar collectors at 60, 80 and 100% plant loads, and found different performance parameters with percentage variations in that parameters. After analyses, it has been found that maximum flow rate achieved for intermediate-pressure steam turbine with maximum outputs but maximum rates of exergy destruction and entropy generation at 100% load. Maximum percentage increments in total and net powers but minimum decrement in heat rate attained at 100% load which prove that plant must be operated at full load without extraction from turbine. Comparative analyses have also been shown maximum heat gain rate, inlet and exergy gain rates from the solar collectors found at 100% but minimum found at 60% load.
In this research project two solar still plants have been fabricated; single and double slope still plants. The exergy and exergy efficiency concepts have been applied for the comparative analyses of both solar stills. Experimental readings, i.e. various temperatures, amounts of distilled water and solar radiations have been taken for solar stills at different time intervals in Indore (22° 43′ 4.51″ N and 75° 49′ 59.88″ E). The percentage variations in the different parameters, i.e. increments in temperature, increments in quantity of water, thermal efficiencies, rates of exergy at inlet/outlet and exergy efficiencies have also been calculated for stills at various solar intensities and time intervals. After experimental and comparative analyses, better outputs have been shown at 14:50 PM for double slope and 14:45 PM for single slope plant due to the cumulative effects of solar radiations on the still plants. During this period thermal/exergy efficiencies, i.e. 46.630/1.949% and 47.259/3.389% were found the best. The performance of single slope solar still has been found better, and 14:30 to 14:50 PM time interval has been recorded superior for the distillation of water through still plants where percentage increments of the performance evaluating parameters were enhanced.