Harmen Droogendijk

Mr. Harmen Droogendijk


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2014 in Bioinspiration & Biomimetics
Verified
Journal Article
Closed access
PDF file
HDHarmen Droogendijk
Harmen Droogendijk
JCJ Casas
J Casas
TST Steinmann
T Steinmann
GKGijs Krijnen
Gijs Krijnen
Despite vigorous growth in biomimetic design, the performance of man-made devices relative to their natural templates is still seldom quantified, a procedure which would however significantly increase the rigour of the biomimetic approach. We applied the ubiquitous engineering concept of a figure of merit (FoM) to MEMS flow sensors inspired by cricket filiform hairs. A well known mechanical model of a hair is refined and tailored to this task. Five criteria of varying importance in the biological and engineering fields are computed: responsivity, power transfer, power efficiency, response time and detection threshold. We selected the metrics response time and detection threshold for building the FoM to capture the performance in a single number. Crickets outperform actual MEMS on all criteria for a large range of flow frequencies. Our approach enables us to propose several improvements for MEMS hair-sensor design.

6 August 2014 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
PDF file
HDHarmen Droogendijk
Harmen Droogendijk
MBM. J. de Boer
M. J. de Boer
RSR. G. P. Sanders
R. G. P. Sanders
GKGijs Krijnen
Gijs Krijnen
Crickets use so-called clavate hairs to sense (gravitational) acceleration to obtain information on their orientation. Inspired by this clavate hair system, a one-axis biomimetic accelerometer has been developed and fabricated using surface micromachining and SU-8 lithography. An analytical model is presented for the design of the accelerometer, and guidelines are derived to reduce responsivity due to flow-induced contributions to the accelerometer's output. Measurements show that this microelectromechanical systems (MEMS) hair-based accelerometer has a resonance frequency of 320 Hz, a detection threshold of 0.10 ms −2 and a dynamic range of more than 35 dB. The accelerometer exhibits a clear directional response to external accelerations and a low responsivity to airflow. Further, the accelerometer's physical limits with respect to noise levels are addressed and the possibility for short-term adaptation of the sensor to the environment is discussed.

19 March 2013 in Micromachines
Verified
Journal Article
Open access
PDF file
HDHarmen Droogendijk
Harmen Droogendijk
CBChristiaan M. Bruinink
Christiaan M. Bruinink
RSRemco G. P. Sanders
Remco G. P. Sanders
GKGijs Krijnen
Gijs Krijnen
We presented an overview of improvements in detection limit and responsivity of our biomimetic hair flow sensors by electrostatic spring-softening (ESS). Applying a DC-bias voltage to our capacitive flow sensors improves the responsively by up to 80% for flow signals at frequencies below the sensor’s resonance. Application of frequency matched AC-bias voltages allows for tunable filtering and selective gain up to 20 dB. Furthermore, the quality and fidelity of low frequency flow measurements can be improved using a non frequency-matched AC-bias voltage, resulting in a flow detection limit down to 5 mm/s at low (30 Hz) frequencies. The merits and applicability of the three methods are discussed.

6 October 2014 in Journal of The Royal Society Interface
Verified
Journal Article
Closed access
HDHarmen Droogendijk
Harmen Droogendijk
RBR. A. Brookhuis
R. A. Brookhuis
MBM. J. de Boer
M. J. de Boer
RSR. G. P. Sanders
R. G. P. Sanders
GKGijs Krijnen
Gijs Krijnen
Flies use so-called halteres to sense body rotation based on Coriolis forces for supporting equilibrium reflexes. Inspired by these halteres, a biomimetic gimbal-suspended gyroscope has been developed using microelectromechanical systems (MEMS) technology. Design rules for this type of gyroscope are derived, in which the haltere-inspired MEMS gyroscope is geared towards a large measurement bandwidth and a fast response, rather than towards a high responsivity. Measurements for the biomimetic gyroscope indicate a (drive mode) resonance frequency of about 550 Hz and a damping ratio of 0.9. Further, the theoretical performance of the fly's gyroscopic system and the developed MEMS haltere-based gyroscope is assessed and the potential of this MEMS gyroscope is discussed.

1 May 2013 in New Journal of Physics
Verified
Journal Article
Open access
HDHarmen Droogendijk
Harmen Droogendijk
RSR G P Sanders
R G P Sanders
GKGijs Krijnen
Gijs Krijnen

23 January 2014
Verified
Book Chapter
Closed access
PDF file
GKGijs Krijnen
Gijs Krijnen
HDHarmen Droogendijk
Harmen Droogendijk
ADAhmad Dagamseh
Ahmad Dagamseh
RJRam K. Jaganatharaja
Ram K. Jaganatharaja
JCJérôme Casas
Jérôme Casas