Salvador Montoya-Alvarez

Mr. Salvador Montoya-Alvarez

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2020 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
FPFernando Pérez-Escamirosa
Fernando Pérez-Escamirosa
SMSalvador Montoya-Alvarez
Salvador Montoya-Alvarez
RORicardo Manuel Ordorica-Flores
Ricardo Manuel Ordorica-Flores
LPLuis Padilla-Sánchez
Luis Padilla-Sánchez
JJJosé Luis Jiménez-Corona
José Luis Jiménez-Corona
AMArturo Minor-Martínez
Arturo Minor-Martínez

17 August 2020 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
SMSalvador Montoya-Alvarez
Salvador Montoya-Alvarez
AMArturo Minor-Martínez
Arturo Minor-Martínez
RORicardo Manuel Ordorica-Flores
Ricardo Manuel Ordorica-Flores
LPLuis Padilla-Sánchez
Luis Padilla-Sánchez
JTJesús Tapia-Jurado
Jesús Tapia-Jurado
FPFernando Pérez-Escamirosa
Fernando Pérez-Escamirosa

6 June 2024 in Journal of Surgical Education
Verified
Journal Article
Closed access
SMSalvador Montoya-Alvarez
Salvador Montoya-Alvarez
MAMinor-Martínez Arturo
Minor-Martínez Arturo
PFPérez-Escamirosa Fernando
Pérez-Escamirosa Fernando
MDMéndez-Gómez Dalia Danely
Méndez-Gómez Dalia Danely
RJRuíz-Lizárraga Jorge
Ruíz-Lizárraga Jorge
TJTapia-Jurado Jesús
Tapia-Jurado Jesús

6 August 2021 in Surgical Innovation
Verified
Journal Article
Closed access
PDF file
VHVictor Gabriel Hernández-Valderrama
Victor Gabriel Hernández-Valderrama
RORicardo Manuel Ordorica-Flores
Ricardo Manuel Ordorica-Flores
SMSalvador Montoya-Alvarez
Salvador Montoya-Alvarez
DHDaniel Haro-Mendoza
Daniel Haro-Mendoza
LOLuis Ochoa-Toledo
Luis Ochoa-Toledo
FPFernando Pérez-Escamirosa
Fernando Pérez-Escamirosa
Background. This article aims to present an innovative design of a steerable surgical instrument for conventional and single-site minimally invasive surgery (MIS), which improves the dexterity and maneuverability of the surgeon while offering a solution to the limitations of current tools. Methods. The steerable MIS instrument consists of a deflection structure with a curved sliding joints design that articulates the distal tip in two additional degrees of freedom (DoFs), relative to the instrument shaft, using transmission by cables. A passive ball-joint mechanism articulates the handle relative to the instrument shaft, improves wrist posture, and prevents collision of instrument handles during single-site MIS procedures. The two additional DoFs of the articulating tip are activated by a thumb-controlled device, using a joystick design mounted on the handle. This steerable MIS instrument was developed by additive manufacturing in a 3D printer using PLA polymer. Results. Prototype testing showed a maximum tip deflection of 60° in the left and right directions, with a total deflection of 120°. With the passive ball-joint fully offset, the steerable tip achieved a deflection of 90° for the right and 40° for the left direction, with a total deflection of 130°. Furthermore, the passive ball-joint mechanism in the handle obtained a maximum range of motion of 60°. Conclusions. This steerable MIS instrument concept offers an alternative to enhance the application fields of conventional and single-site MIS, increasing manual dexterity of the surgeon and the ability to reach narrow anatomies from other directions.

7 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
DMDalia Danely Méndez-Gómez
Dalia Danely Méndez-Gómez
AMArturo Minor-Martínez
Arturo Minor-Martínez
SMSalvador Montoya-Alvarez
Salvador Montoya-Alvarez
FPFernando Pérez-Escamirosa
Fernando Pérez-Escamirosa
JCJessica Cantillo-Negrete
Jessica Cantillo-Negrete
Axillary crutches assist people with lower limb injuries but can lead to upper limb strain with extended use. Spring-loaded crutches offer a potential solution, yet they are rarely tested in clinical settings. This study developed spring-loaded crutches with an integrated force-measuring system to analyze gait dynamics. Three prototypes, each with different spring constants (k), were tested. To measure ground reaction force (GRF), a Nylamid cover was around the crutch stem. Two participants with different weights completed a 15-m route using both the designed spring-loaded and standard crutches. Findings showed that spring-loaded crutches increased mean GFR and impulse, with the prototype matched to the user’s weight yielding the best results. The study’s findings suggest that when properly adjusted to the user’s weight, spring-loaded crutches can offer significant improvements in gait, which may have important implications for the design of mobility assistive devices.

11 August 2025 in Surgical Endoscopy
Verified
Journal Article
Open access
Daniel LoriasDaniel Lorias
Daniel Lorias
SCSandra Karina Díaz Cardona
Sandra Karina Díaz Cardona
LVLeobardo Elí Sánchez Velasco
Leobardo Elí Sánchez Velasco
RORicardo Manuel Ordorica-Flores
Ricardo Manuel Ordorica-Flores
AMArturo Minor-Martínez
Arturo Minor-Martínez
FPFernando Pérez-Escamirosa
Fernando Pérez-Escamirosa
Background: The aim of this study is to present the construct validity of the ScopePro Trainer system and determine its effectiveness as a training and objective assessment tool for surgeons’ psychomotor laparoscopic skills. Methods: Four surgeons, eight PG2 to PG4 residents, and twenty medical students participated in this study. All participants performed three FLS-based tasks using conventional laparoscopic instruments and the ScopePro Trainer system. Using the linearity principle of the spiral, a passive marker was added to each instrument, shaped like a spiral. Six metrics related to time, linear motion, and angular motion were used to assess the laparoscopic performance of the participants in all tasks. Statistical analysis was performed using the analysis of variance (ANOVA) test, followed by a Student’s t test with Tukey’s correction for multiple testing. Results: The performance of ScopePro Trainer is illustrated by the graphical representation of the instruments' paths and the calculations of metrics derived from their position and rotation. Outcomes presented significant differences in the participant's skills during the execution of three surgical training tasks. Conclusions: The ScopePro Trainer system has been presented and successfully validated. Outcomes showed that ScopePro was able to differentiate between participants with varying levels of laparoscopic expertise. The ScopePro Trainer offers an alternative to traditional tracking systems for analyzing the rotational motion of surgical instruments.