Panya Aroonjarattham

Panya Aroonjarattham

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2016 in Engineering Journal
Verified
Journal Article
Open access
PDF file
PAPanya Aroonjarattham
Panya Aroonjarattham
The Parametric Study of High Pressure Gas Burner Affect Thermal Efficiency

20 October 2022 in Injury
Verified
Journal Article
Open access
PPPathomchat Pisitwattanaporn
Pathomchat Pisitwattanaporn
NSNadhaporn Saengpetch
Nadhaporn Saengpetch
STSorawut Thamyongkit
Sorawut Thamyongkit
TWThitiphol Wanitchanont
Thitiphol Wanitchanont
PSPaphon Sa-ngasoongsong
Paphon Sa-ngasoongsong
PAPanya Aroonjarattham
Panya Aroonjarattham
Split type of greater tuberosity fracture has variety of surgical treatment options. This study aimed to compare the biomechanics property of additional cuff suture and other fracture fixation techniques. Fifteen porcine humeri were categorized into three groups of fixation techniques those were proximal humeral internal locking system (PHILOS) plate with 2 cuff sutures, nonlocking (conventional, 3.5 mm) T-plate with 2 cuff sutures and T-plate with washer that had additional cuff suture (novel technique). Fracture was created by greater tuberosity osteotomy with 50˚ inclination to the line of surgical neck and then fixed with different prescribed techniques. Displacement of fracture site was measured with universal testing machine. The maximum forces to produce 3 mm, 5 mm of displacement and load to failure were recorded. The average loads to reach 3 mm, 5 mm displacement and failure were 30.8 N, 45.4 N and 161 N for nonlocking T-plate; 76.6 N, 99.2 N and 144 N for PHILOS plate; 95.8 N, 120 N and 197 N for novel technique. The differences among three groups were significant in load to displacement at 3 and 5 mm (but not significant in load to failure). For load to reach 3- and 5-mm displacement, PHILOS plate and novel technique were significantly stronger than nonlocking T-plate (P < 0.05). For load to reach 3 and 5 mm displacement, novel technique was stronger than PHILOS plate but not significant (P > 0.05). For load to failure, novel technique was stronger than nonlocking plate and PHILOS plate but not significant (P < 0.05). The important factors affecting the strength of fracture fixation are type of plate and numbers of suture augmentation that tie to the plate. Fixation with additional cuff suture showed the superior biomechanics of load to reach 3 mm, 5 mm displacement with better load to failure compared with PHILOS plate and conventional T-plate alone.

4 June 2026 in The Knee
Verified
Journal Article
Closed access
NSNadhaporn Saengpetch
Nadhaporn Saengpetch
APAkarawint Poorapeeravong
Akarawint Poorapeeravong
CSChinnawut Suriyonplengsaeng
Chinnawut Suriyonplengsaeng
PAPanya Aroonjarattham
Panya Aroonjarattham
CSChompunut Somtua
Chompunut Somtua
PKPinkawas Kongmalai
Pinkawas Kongmalai

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
WLWasan Leelatanaroek
Wasan Leelatanaroek
PAPanya Aroonjarattham
Panya Aroonjarattham
CSChompunut Somtua
Chompunut Somtua
Chillies are one of the most popular spices consumed in daily cuisine. They contain a high moisture content after harvest. This research aimed to develop the hy Chillies are one of the most popular spices consumed in daily cuisine. They contain a high moisture content after harvest. This research aimed to develop the hy

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
NRNattawat Rattanapan
Nattawat Rattanapan
STSommart Thongkom
Sommart Thongkom
KAKitti Aroonjarattham
Kitti Aroonjarattham
PAPanya Aroonjarattham
Panya Aroonjarattham
CSChompunut Somtua
Chompunut Somtua
Hip replacement surgery is a treatment for patients with hip osteoarthritis. Currently, the common femoral stem of a hip prosthesis is a solid figure made from Hip replacement surgery is a treatment for patients with hip osteoarthritis. Currently, the common femoral stem of a hip prosthesis is a solid figure made from

9 April 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
YRYanin Ruangrittisak
Yanin Ruangrittisak
KAKitti Aroonjarattham
Kitti Aroonjarattham
PAPromtpong Anuchitchanchai
Promtpong Anuchitchanchai
CSChompunut Somtua
Chompunut Somtua
PAPanya Aroonjarattham
Panya Aroonjarattham
The knee is one of the important joint of human body to carry the body load. The deformities of knee joint affect the human activities. To treat the deformity knee, close-wedge High Tibial Osteotomy (HTO) was one of the popular techniques to adjust the strain distribution on the deformity knee close to the normal by shifting the mechanical axis toward the lateral side. This research aims to evaluate the strain distribution on the varus knee corrected by zero degree, three degrees valgus and three degreesvarus close-wedge HTO under walking load. The result was shown the lowest strain distribution occur on the three degreesvarus model following by zero degree and three degree valgus model respectively. The surgeon should be correct the varus knee by three degreesvarus close-wedge HTO to get the strain distribution on the bone closet to the normal knee.