Zsuzsanna Piros

Dr. Zsuzsanna Piros

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
ZPZsuzsanna Piros
Zsuzsanna Piros
KDKispál Kristóf Dániel
Kispál Kristóf Dániel
RSReka Szekeres
Reka Szekeres
TBTakács Barbara
Takács Barbara
Rita KissRita Kiss
Rita Kiss
BJBela Juhasz
Bela Juhasz
Background/Objectives: Over the past few decades, many studies have been conducted to explore the link between tinnitus and lipid metabolism, yielding inconsistent results. In our current study, we compared the prevalence of various lipid metabolism abnormalities in patients with chronic subjective idiopathic tinnitus (CSIT) to the official prevalence data of dyslipidaemia in the general adult Hungarian population. To counteract the distorting effect of the co-increase in both conditions with age, we also examined this relationship by age groups. Methods: A total of 231 adult patients, suffering from CSIT, who underwent rheological treatment at the Department of Otorhinolaryngology and Head and Neck Surgery of the Clinical Center (University of Debrecen, Debrecen, Hungary), were involved in a retrospective study. Total cholesterol, serum triglycerides, LDL-C, ApoB, HDL-C, ApoA, and Lp(a) were utilized. Results: For the aggregated data, we found that the occurrence of dyslipidaemia among our patients (78.35%) significantly exceeded the corresponding official data about the occurrence of dyslipidaemia in the whole adult Hungarian population (16.51%). This finding was supported by our age-specific approach and the results imply an association between CSIT and dyslipidaemia. This finding suggests an association between CSIT and dyslipidaemia. Conclusions: Considering the relationship between CSIT and dyslipidaemia suggested by our results, tinnitus could be an indicator of dyslipidaemia, even at a young age. Therefore, careful investigation of each tinnitus patient, along with a lipidological evaluation for those with CSIT, may be recommended. This approach could lower mortality from lipid-related diseases, particularly atherosclerosis and its complications, by serving as the first line of defence against a harmful and life-threatening lipid-related conditions.

30 June 2026 in Audiology Research
Verified
Journal Article
Open access
PDF file
ZPZsuzsanna Piros
Zsuzsanna Piros
SRSzilárd Gyula Rezes
Szilárd Gyula Rezes
Rita KissRita Kiss
Rita Kiss
BLBeáta Lelesz
Beáta Lelesz
GUGyula Ujlaki
Gyula Ujlaki
ZSZoltán Szilvássy
Zoltán Szilvássy
Background/Objectives: This study evaluated the intra-session repeatability, reliability, and clinical consistency of resonance frequency derived from pressure-less acoustic immittance (PLAI), and compared the results with those obtained using conventional multifrequency tympanometry under identical clinical conditions. Methods: In this pilot methodological comparison study, resonance frequency (RF) measurements were obtained in 15 subjects (30 ears) using multifrequency tympanometry (MFT) and pressure-less acoustic immittance (PLAI). Three consecutive measurements were performed for each ear using both methods. Agreement between methods was evaluated using Bland–Altman analysis. Within-method repeatability was assessed using range, coefficient of variation, repeatability coefficient, and intraclass correlation coefficients. Results: PLAI demonstrated lower intra-session variability than MFT. The mean within-series SD was 96.6 Hz for MFT and 10.5 Hz for PLAI. The coefficient of variation was 9.3% for MFT and 3.2% for PLAI, while intraclass correlation coefficients were 0.60 and 0.83, respectively. The repeatability coefficient was ±367 Hz for MFT and ±47 Hz for PLAI. Bland–Altman analysis revealed a systematic difference between the two methods, with a mean bias of 580.7 Hz and 95% limits of agreement between 247.5 Hz and 913.9 Hz, indicating that the two methods are not interchangeable. Conclusions: PLAI demonstrated higher repeatability than MFT. Its lower variability may support a more consistent clinical interpretation; PLAI-derived RF may therefore represent a stable method-specific parameter for middle ear assessment. However, RF values should be interpreted within method-specific frameworks.