Chanida Puangpila

Dr. Chanida Puangpila


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Talanta
Verified
Journal Article
Closed access
WKWanpen Khongpet
Wanpen Khongpet
SPSomkid Pencharee
Somkid Pencharee
CPChanida Puangpila
Chanida Puangpila
SHSupaporn Kradtap Hartwell
Supaporn Kradtap Hartwell
SLSomchai Lapanantnoppakhun
Somchai Lapanantnoppakhun
Jaroon JakmuneeJaroon Jakmunee
Jaroon Jakmunee

24 September 2018 in Environmental Chemistry
Verified
Journal Article
Closed access
PDF file
CPChanida Puangpila
Chanida Puangpila
JJJaroon Jakmunee
Jaroon Jakmunee
SPSomkid Pencharee
Somkid Pencharee
WPWipada Pensrisirikul
Wipada Pensrisirikul
Environmental context: A widespread pollutant in groundwater, rivers and lakes is nitrite, which is commonly determined batchwise by using colourimetry. The batchwise method, however, requires relatively large and expensive instrumentation, and hence is unsuitable for in-field measurements. This work introduces a simple and portable colourimetric analyser based on a mobile-phone camera for monitoring nitrite concentrations in environmental water samples. A cost-effective and portable colourimetric analyser installed on a mobile phone was used to measure nitrite in water samples in Chiang Mai City, Thailand. The colourimetric detection was based on the Griess reaction, in which nitrite ion reacts with sulfanilic acid under acidic conditions to produce a diazonium salt that further reacts with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a red–violet azo dye. Under controlled conditions using a light-tight box with LED flash lights, images of the red–violet solution were captured using a built-in camera and further analysed by a program, Panalysis, on the mobile phone. The calibration graph was created by measuring the red colour intensity of a series of standard nitrite solutions from 0.09–1.8 mg N L-1. The calibration equation was then automatically stored for nitrite analysis. The results demonstrated good performance of the mobile phone analyser as an analytical instrument. The accuracy (RE <4%) and precision (RSD = 1%, intra- and inter-day) were also obtained with a detection limit of 0.03 mg N L-1 and a sample throughput of 40 samples per hour. Our results establish this simple, inexpensive and portable device as a reliable in-field monitor of nitrite in environmental waters.

30 May 2012 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
CPChanida Puangpila
Chanida Puangpila
TNThumnoon Nhujak
Thumnoon Nhujak
Ziad El RassiZiad El Rassi
Ziad El Rassi

7 December 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
SKSupada Khonyoung
Supada Khonyoung
PMPraphatsorn Mangkronkaew
Praphatsorn Mangkronkaew
PKPuttaporn Klayprasert
Puttaporn Klayprasert
CPChanida Puangpila
Chanida Puangpila
Muthukumaran PMuthukumaran P
Muthukumaran P
Jaroon JakmuneeJaroon Jakmunee
Jaroon Jakmunee
In order to identify carcinoembryonic antigen (CEA) in serum samples, an innovative smartphone-based, label-free electrochemical immunosensor was created without the need for additional labels or markers. This technology presents a viable method for on-site cancer diagnostics. The novel smartphone-integrated, label-free immunosensing platform was constructed by nanostructured materials that utilize the layer-by-layer (LBL) assembly technique, allowing for meticulous control over the interface. Detection relies on direct interactions without extra tagging agents, where ordered graphene oxide (GO), carbon nanotubes (CNTs), and copper oxide nanoparticles (CuONPs) were sequentially deposited onto a screen-printed carbon electrode (SPCE), designated as CuONPs/CNTs/GO/SPCE. This significantly amplifies the electrochemical signal, allowing for the detection of low concentrations of target molecules of CEA. The LBL approach enables the precise construction of multi-layered structures on the sensor surface, enhancing their activity and optimizing the electrochemical performance for CEA detection. These nanostructured materials serve as efficient carriers to significantly increase the surface area, conductivity, and structural support for antibody loading, thus improving the sensitivity of detection. The detection of carcinoembryonic antigen (CEA) in this electrochemical immunosensing transducer is based on a decrease in the current response of the [Fe(CN)6]3−/4− redox probes, which occurs in proportion to the amount of the immunocomplex formed on the sensor surface. Under the optimized conditions, the immunosensor exhibited good detection of CEA with a linear range of 0.1–5.0 ng mL−1 and a low detection limit of 0.08 ng mL−1. This label-free detection approach, based on signal suppression due to immunocomplex formation, is highly sensitive and efficient for measuring CEA levels in serum samples, with higher recovery ranges of 101% to 112%, enabling early cancer diagnosis. The immunosensor was successfully applied to determine CEA in serum samples. This immunosensor has several advantages, including simple fabrication, portability, rapid analysis, high selectivity and sensitivity, and good reproducibility with long-term stability over 21 days. Therefore, it has the potential for point-of-care diagnosis of lung cancer.


22 January 2020 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
WKWanpen Khongpet
Wanpen Khongpet
PYPattama Yanu
Pattama Yanu
SPSomkid Pencharee
Somkid Pencharee
CPChanida Puangpila
Chanida Puangpila
SHSupaporn Kradtap Hartwell
Supaporn Kradtap Hartwell
Jaroon JakmuneeJaroon Jakmunee
Jaroon Jakmunee
A miniaturized microfluidic hydrodynamic sequential injection system for multi-parameter analysis with a sensitive colorimetric detection was developed to improve the analytical performance for the measurement of phosphate, nitrite, and nitrate based on molybdenum blue and Griess methods. A homemade colorimetric detection with a light emitting diode as a light source and phototransistor light sensor was integrated into the microfluidic platform to achieve a low cost compact system with low reagent consumption and high sensitivity. Under the optimized working conditions, a linear calibration graph of phosphate (two working range), nitrite and nitrate (as nitrogen, N) in the range of 0.01–0.1 and 0.3–1.0 mg of PO4 3− P L−1, 0.005–0.05 mg of NO2 − N L−1 and 0.01–0.12 mg of NO3 − N L−1, respectively were achieved with a sample-throughput of 10 h−1. The limit of detections were 0.005 mg of PO4 3− P L−1, 0.0026 mg of NO2 − N L−1 and 0.005 mg of NO3 − N L−1. The percentage of recovery for phosphate, nitrite, and nitrate were 90.3–115.0, 90.0–117.0 and 91.3–117.0, respectively, with relative standard deviations in the range of 1.07–4.90%. Capabilities of the developed device for consecutive analysis of multiple analytes were demonstrated to be an excellent choice for water quality monitoring.