Arjen Meijer

Dr. Arjen Meijer


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Resources, Conservation and Recycling
Verified
Journal Article
Open access
ASA. van Stijn
A. van Stijn
LEL.C. Malabi Eberhardt
L.C. Malabi Eberhardt
BJB. Wouterszoon Jansen
B. Wouterszoon Jansen
AMArjen Meijer
Arjen Meijer

4 May 2017 in Building Research & Information
Verified
Journal Article
Open access
PBPaula van Den Brom
Paula van Den Brom
AMArjen Meijer
Arjen Meijer
Henk VisscherHenk Visscher
Henk Visscher
The difference between actual and calculated energy is called the ‘energy-performance gap’. Possible explanations for this gap are construction mistakes, improper adjusting of equipment, excessive simplification in simulation models and occupant behaviour. Many researchers and governmental institutions think the occupant is the main cause of this gap. However, only limited evidence exists for this. Therefore, an analysis is presented of actual and theoretical energy consumption based on specific household types and building characteristics. Using a large dataset (1.4 million social housing households), the average actual and theoretical energy consumptions (gas and electricity) of different household types and characteristics (income level, type of income, number of occupants and their age) were compared for each energy label. Additionally, the 10% highest and lowest energy-consuming groups were analysed. The use of combinations of occupant characteristics instead of individual occupant characteristics provides new insights into the influence of the occupant on energy demand. For example, in contrast to previous studies, low-income households consume more gas per m2 (space heating and hot water) than households with a high income for all types of housing. Furthermore, the performance gap is caused not only by the occupant but also by the assumed building characteristics.

6 February 2009 in Environmental Science & Technology
Verified
Journal Article
Open access
SHStefanie Hellweg
Stefanie Hellweg
ALAlastair Leyland
Alastair Leyland
RBRaffaella Bruzzi
Raffaella Bruzzi
AMArjen Meijer
Arjen Meijer
RRRalph K. Rosenbaum
Ralph K. Rosenbaum
TMThomas E. McKone
Thomas E. McKone
Neglecting health effects from indoor pollutant emissions and exposure, as currently done in Life Cycle Assessment (LCA), may result in product or process optimizations at the expense of workers’ or consumers’ health. To close this gap, methods for considering indoor exposure to chemicals are needed to complement the methods for outdoor human exposure assessment already in use. This paper summarizes the work of an international expert group on the integration of human indoor and outdoor exposure in LCA, within the UNEP/SETAC Life Cycle Initiative. A new methodological framework is proposed for a general procedure to include human-health effects from indoor exposure in LCA. Exposure models from occupational hygiene and household indoor air quality studies and practices are critically reviewed and recommendations are provided on the appropriateness of various model alternatives in the context of LCA. A single-compartment box model is recommended for use as a default in LCA, enabling one to screen occupational and household exposures consistent with the existing models to assess outdoor emission in a multimedia environment. An initial set of model parameter values was collected. The comparison between indoor and outdoor human exposure per unit of emission shows that for many pollutants, intake per unit of indoor emission may be several orders of magnitude higher than for outdoor emissions. It is concluded that indoor exposure should be routinely addressed within LCA.

1 November 2010 in Building and Environment
Verified
Journal Article
Closed access
IBInge Blom
Inge Blom
LILaure Itard
Laure Itard
AMArjen Meijer
Arjen Meijer

1 August 2011 in Building and Environment
Verified
Journal Article
Closed access
IBInge Blom
Inge Blom
LILaure Itard
Laure Itard
AMArjen Meijer
Arjen Meijer

23 May 2003 in Progress in Photovoltaics: Research and Applications
Verified
Journal Article
Open access
PDF file
AMArjen Meijer
Arjen Meijer
MHMark Huijbregts
Mark Huijbregts
JSJ. J. Schermer
J. J. Schermer
LRL. Reijnders
L. Reijnders
A higher conversion efficiency of photovoltaic modules does not automatically imply a lower environmental impact, when the life‐cycle of modules is taken into account. An environmental comparison is carried out between the production and use phase, except maintenance, of an indium–gallium–phosphide (InGaP) on multicrystalline silicon (mc‐Si) tandem module, a thin‐film InGaP cell module and a mc‐Si module. The evaluation of the InGaP systems was made for a very limited industrial production scale. Assuming a fourfold reuse of the GaAs substrates in the production of the thin‐film InGaP (half) modules, the environmental impacts of the tandem module and of the thin‐film InGaP module are estimated to be respectively 50 and 80% higher than the environmental impact of the mc‐Si module. The energy payback times of the tandem module, the thin‐film InGaP module and the mc‐Si module are estimated to be respectively 5.3, 6.3 and 3.5 years. There are several ways to improve the life‐cycle environmental performance of thin‐film InGaP cells, including improved materials efficiency in production and reuse of the GaAs wafer and higher energy efficiency of the metalorganic chemical vapour deposition process. Copyright © 2003 John Wiley & Sons, Ltd.