OBJECTIVE: Placement of a ventricular drain is one of the most common neurosurgical procedures. However, a higher rate of successful placements with this freehand procedure is desirable. The authors’ objective was to develop a compact navigational augmented reality (AR)–based tool that does not require rigid patient head fixation, to support the surgeon during the operation. METHODS: Segmentation and tracking algorithms were developed. A commercially available Microsoft HoloLens AR headset in conjunction with Vuforia marker-based tracking was used to provide guidance for ventriculostomy in a custom-made 3D-printed head model. Eleven surgeons conducted a series of tests to place a total of 110 external ventricular drains under holographic guidance. The HoloLens was the sole active component; no rigid head fixation was necessary. CT was used to obtain puncture results and quantify success rates as well as precision of the suggested setup. RESULTS: In the proposed setup, the system worked reliably and performed well. The reported application showed an overall ventriculostomy success rate of 68.2%. The offset from the reference trajectory as displayed in the hologram was 5.2 ± 2.6 mm (mean ± standard deviation). A subgroup conducted a second series of punctures in which results and precision improved significantly. For most participants it was their first encounter with AR headset technology and the overall feedback was positive. CONCLUSIONS: To the authors’ knowledge, this is the first report on marker-based, AR-guided ventriculostomy. The results from this first application are encouraging. The authors would expect good acceptance of this compact navigation device in a supposed clinical implementation and assume a steep learning curve in the application of this technique. To achieve this translation, further development of the marker system and implementation of the new hardware generation are planned. Further testing to address visuospatial issues is needed prior to application in humans.
4 July 2023 in Journal of Neurological Surgery Part A: Central European Neurosurgery
Background Ventriculostomy (VST) is a frequent neurosurgical procedure. Freehand catheter placement represents the standard current practice. However, multiple attempts are often required. We present augmented reality (AR) headset guided VST with in-house developed head models. We conducted a proof of concept study in which we tested AR-guided as well as freehand VST. Repeated AR punctures were conducted to investigate if a learning curve can be derived. Methods Five custom-made 3D-printed head models, each holding an anatomically different ventricular system, were filled with agarose gel. Eleven surgeons placed two AR-guided as well as two freehand ventricular drains per head. A subgroup of four surgeons did a total of three series of AR-guided punctures each to test for a learning curve. A Microsoft HoloLens served as the hardware platform. The marker-based tracking did not require rigid head fixation. Catheter tip position was evaluated in computed tomography scans. Results Marker-tracking, image segmentation, and holographic display worked satisfactorily. In freehand VST, a success rate of 72.7% was achieved, which was higher than under AR guidance (68.2%, difference not statistically significant). Repeated AR-guided punctures increased the success rate from 65 to 95%. We assume a steep learning curve as repeated AR-guided punctures led to an increase in successful attempts. Overall user experience showed positive feedback. Conclusions We achieved promising results that encourage the continued development and technical improvement. However, several more developmental steps have to be taken before an application in humans can be considered. In the future, AR headset–based holograms have the potential to serve as a compact navigational help inside and outside the operating room.
The surgical treatment of recurrent adenomas can be challenging. Intraoperative magnetic resonance imaging (iMRI) can improve the orientation and increase the safe extent of resection. We conducted a quantitative and qualitative retrospective analysis of recurrent adenomas treated by endoscopic or microscopic iMRI-assisted transsphenoidal surgery. A total number of 59 resections were selected. Detailed volumetric measurements, tumor characteristics, and MRI features of intraoperative remnants were evaluated. Intraoperative MRI increased the gross total resection (GTR) rate from 33.9% to 49.2%. Common locations of tumor remnants after iMRI were the clivus, the wall of the cavernous sinus or the perforation of the diaphragm. Increasing tumor volume and the microscopic technique were significantly associated with further resection after iMRI in the univariate analysis (p = 0.004, OR 1.6; p = 0.009, OR 4.4). Only the increasing tumor volume was an independent predictor for further resection (p = 0.007, OR 1.5). A significantly higher proportion of GTRs was achieved with the endoscopic technique (p = 0.001). Patients with a large recurrent pituitary adenoma who underwent microscopic transsphenoidal resection were the most likely to benefit from iMRI regarding the extent of resection. Occult invasions of the cavernous sinus and/or the clivus were the most common findings leading to further resection of tumor remnants after iMRI.
Image-guided neurosurgical interventions are challenging due to the complex anatomy of the brain and the inherent risk of damaging vital structures. This paper presents a neurosurgical planning tool for safe and effective neurosurgical interventions, minimizing the risk through optimized access planning. The strengths of the proposed system are the integration of multiple risk structures combined into a holistic model for fast and intuitive user interaction, and a modular architecture. The tool is intended to support neurosurgeons to quickly determine the most appropriate surgical entry point and trajectory through the brain with minimized risk. The user interface guides a user through the decision-making process and may save planning time of neurosurgical interventions. The navigation tool has been interfaced to the Robot Operating System, which allows the integration into automated workflows and the planning of linear and nonlinear trajectories. Determined risk structures and trajectories can be visualized intuitively as a projection map on the skin or cortical surface. Two risk calculation modes (strict and joint) are offered to the neurosurgeons, depending on the intracranial procedure's type and complexity. A qualitative evaluation with clinical experts shows the practical relevance, while a quantitative performance and functionality analysis proves the robustness and effectiveness of the system.