A laser-induced fluorescence lidar has been developed for detecting the concentration of fluorescent aerosols in the air. The fluorescence lidar was constructed with a pulsed fourth-harmonic Nd:YAG laser at the ultraviolet wavelength of 266 nm with a repetition rate of 10 Hz. A 250 mm diameter custom telescope was used to collect optical spectra ranging from 260 to 560 nm. Fluorescence signals with wavelengths ranging from 310–440 nm were extracted, exploring a filter with a bandwidth of 130 nm. The preliminary experiments were conducted at the campus of Xi’an University of Technology, in which the fluorescence signals of atmospheric fluorescent aerosols were continuously collected from 20:00 to 23:00 CST on 13 December 2017. Based on the fluorescence lidar equation, the density of fluorescence signals was calibrated using Rayleigh–Mie scattering signals and ozone concentration data at the ground level. Measured ranges show a strong dependence with the concentrations due to its absorption characteristics at ultraviolet 266 nm. Moreover, the concentration of the biogenic particles was also calculated based on the raw data of the fluorescence channel. Obtained results show that the concentration of biogenic particles in the Xi’an area varied greatly, ranging from 3456 particles · to 8835 particles · during winter.
Poisson distributions have the characteristic of equality between their variance and mean values. By constructing a calculation model of the temporal variance and spatial variance, the relationship between the variance and mean values of lidar analog data and photon-counting data can be analyzed. The calculation results show that the photon-counting data from far field have the distribution property of equality between the variances and the corresponding mean values, while the analog data for the whole probing traces do not. In this paper, by analyzing the distribution properties of the spatial variance and temporal variance of lidar data, the dead time of photon-counting data was estimated, and the threshold voltage of the photon-counting system and the linear working range of photomultiplier tube were evaluated. The results show that the linear working range of the high voltage for the photomultiplier tube in the ultraviolet elastic scanning lidar is between −500 V and −1000 V, and the dead time and threshold voltage of the photon-counting system in the Licel transient recorder are 3.488 ns and 1.20 mV, respectively. Meanwhile, a novel gluing method between analog data and photon-counting data is presented, based on the calculation results of the variance distribution of lidar data. The linear transfer coefficients were determined by minimizing the differences between the variance and mean of the transformed photon-counting data in the near filed with high signal to noise ratio. The glued data were distributed to express the atmospheric conditions uniformly.
Using UV lidar to induce bioaerosol fluorescence is an effective method for detecting atmospheric bioaerosols. In this work, vertex component analysis, combined with the genetic algorithm, is proposed to analyze the received fluorescence spectra from UV LIF lidar. The pure components in the mixed fluorescence spectra are extracted using the vertex component analysis method, and then the genetic algorithm is adopted to fit the proportion of each component in the mixed spectra. The echo signals of the UV LIF lidar are simulated using the Voigt function at the excitation wavelength of 266 nm. All components can be correctly identified. Low-frequency noise is one of the significant interference factors when non-biological particles are present in the atmosphere. For three mixed components—bacillus subtilis, escherichia coli, and meadow oat pollen—the genetic algorithm can predict the proportion of each component with high accuracy, even in the presence of low-frequency noise. The stability of the algorithm was also explored with mixtures of four and five components, along with low-frequency noise. The residual predictive deviation (RPD) for all cases ranged from 2.0 to 28.2. It was concluded that the genetic algorithm can effectively predict the proportions in the mixed fluorescence spectra.
7 January 2025 in Measurement Science and Technology
Real-time monitoring of atmospheric bioaerosol concentrations primarily involves analyzing the total fluorescence signal, which does not provide the specific content of each component. Since mixed fluorescence spectra contain information about the composition and content of bioaerosols, by employing multivariate analysis of the spectra and using multivariate regression algorithms, it is possible to extract the components from the mixed spectra and predict the proportion of each component. In this study, upon the extracted components in the mixed fluorescence spectra by vertex component analysis, we compared several quantitative analysis models for their accuracy in predicting bioaerosol proportions. The models can obtain the proportion of each component effectively when three components exist in the mixed spectra, with 2D convolutional neural networks (CNNs) having the best effect. To ascertain the algorithms’ stability, discussions on scenarios involving multiple components (four-component and five-component mixtures) as well as low-frequency noise conditions have also been included. The degree of impact on Bacillus Subtilis is the biggest when the number of mixed components increased. For the CNNs, the interference caused by the increase in the number of components is relatively higher than that of low frequency noise. When the number of the component is increased, the prediction effect of the algorithms is affected with considerable low frequency noise. Principal component regression and back propagation neural networks can maintain a relatively stable and reliable prediction effect. It is possible to match the most suitable algorithms for different components, thereby obtaining more accurate measurement results and providing a certain reference value for the detection of bioaerosol concentrations.