Lucas Vellame

Lucas Vellame

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in Pesquisa Agropecuária Tropical
Verified
Journal Article
Open access
PDF file
RPRodrigo Moura Pereira
Rodrigo Moura Pereira
DCDerblai Casaroli
Derblai Casaroli
LVLucas Vellame
Lucas Vellame
JJJosé Alves Júnior
José Alves Júnior
AEAdão Wagner Pêgo Evangelista
Adão Wagner Pêgo Evangelista
Large farmland areas and the knowledge on the interaction between solar radiation and vegetation canopies have increased the use of data from orbital remote sensors in sugarcane monitoring. However, the constituents of the atmosphere affect the reflectance values obtained by imaging sensors. This study aimed at improving a sugarcane Leaf Area Index (LAI) estimation model, concerning the Normalized Difference Vegetation Index (NDVI) subjected to atmospheric correction. The model generated by the NDVI with atmospheric correction showed the best results (R2 = 0.84; d = 0.95; MAE = 0.44; RMSE = 0.55), in relation to the other models compared. LAI estimation with this model, during the sugarcane plant cycle, reached a maximum of 4.8 at the vegetative growth phase and 2.3 at the end of the maturation phase. Thus, the use of atmospheric correction to estimate the sugarcane LAI is recommended, since this procedure increases the correlations between the LAI estimated by image and by plant parameters.

1 October 2009 in Revista Brasileira de Engenharia Agrícola E Ambiental
Verified
Journal Article
Open access
PDF file
LVLucas Vellame
Lucas Vellame
MFMauricio A. Coelho Filho
Mauricio A. Coelho Filho
VPVital P. S. Paz
Vital P. S. Paz
Objetivou-se, com esse trabalho avaliar o método Granier (sonda de dissipação térmica) para a cultura da manga quanto à viabilidade de uso em condições de campo e ajustar a equação de determinação do fluxo de seiva com base em medidas lisimétricas, iniciando-se com três mudas da variedade Tommy Atkins, plantadas em vasos que, colocados sobre plataforma de pesagem, funcionaram como lisímetros. A área condutora do caule (AS) foi determinada por meio da aplicação de corantes. Medidas de transpiração por lisimetria nas plantas foram realizadas em vaso e estimativas do fluxo de seiva com sonda de dissipação térmica (SDT). Em um ramo de planta adulta foram instaladas uma sonda de dissipação térmica e um sensor de balanço de calor caulinar. Os resultados demonstraram que, usando os coeficientes originais da equação de Granier, o método subestima em 31% o fluxo de seiva (FS) diário em relação à transpiração medida pelos lisímetros; modificando os parâmetros empíricos da equação FS = 0,00017k1,231AS o desvio médio apresentado foi de -1,4%, com boa precisão (R² = 0,89). O método da SDT e balanço de calor caulinar apresentaram boa concordância entre os valores.

1 October 2024 in Journal of Hydrologic Engineering
Verified
Journal Article
Closed access
LVLucas Vellame
Lucas Vellame
ARArmin Raabe
Armin Raabe
QLQuirijn de Jong van Lier
Quirijn de Jong van Lier
GAGeovana Paim Araújo
Geovana Paim Araújo
José AraújoJosé Araújo
José Araújo

24 August 2023 in Hydrological Processes
Verified
Journal Article
Closed access
JCJuliana Alcântara Costa
Juliana Alcântara Costa
LVLucas Vellame
Lucas Vellame
CCCarlos Alexandre Gomes Costa
Carlos Alexandre Gomes Costa
Joaquín Navarro HeviaJoaquín Navarro Hevia
Joaquín Navarro Hevia
CLClaudivan Feitosa Lacerda
Claudivan Feitosa Lacerda
José AraújoJosé Araújo
José Araújo

1 June 2012 in Engenharia Agrícola
Verified
Journal Article
Open access
PDF file
RCRubens Duarte Coelho
Rubens Duarte Coelho
LVLucas Vellame
Lucas Vellame
EJEusímio F. Fraga Júnior
Eusímio F. Fraga Júnior
Most studies on measures of transpiration of plants, especially woody fruit, relies on methods of heat supply in the trunk. This study aimed to calibrate the Thermal Dissipation Probe Method (TDP) to estimate the transpiration, study the effects of natural thermal gradients and determine the relation between outside diameter and area of xylem in 'Valencia' orange young plants. TDP were installed in 40 orange plants of 15 months old, planted in boxes of 500 L, in a greenhouse. It was tested the correction of the natural thermal differences (DTN) for the estimation based on two unheated probes. The area of the conductive section was related to the outside diameter of the stem by means of polynomial regression. The equation for estimation of sap flow was calibrated having as standard lysimeter measures of a representative plant. The angular coefficient of the equation for estimating sap flow was adjusted by minimizing the absolute deviation between the sap flow and daily transpiration measured by lysimeter. Based on these results, it was concluded that the method of TDP, adjusting the original calibration and correction of the DTN, was effective in transpiration assessment.

1 March 2012 in Revista Brasileira de Fruticultura
Verified
Journal Article
Open access
PDF file
LVLucas Vellame
Lucas Vellame
RCRubens Duarte Coelho
Rubens Duarte Coelho
JTJoão Batista Tolentino
João Batista Tolentino