Peter Aquilina

Prof. Dr. Peter Aquilina

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in British Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
PAPeter Aquilina
Peter Aquilina
UCUphar Chamoli
Uphar Chamoli
WPWilliam C.H. Parr
William C.H. Parr
PCPhilip Clausen
Philip Clausen
SWStephen Wroe
Stephen Wroe

Verified
Journal Article
Open access
PAPeter Aquilina
Peter Aquilina
WPWilliam C. H. Parr
William C. H. Parr
UCUphar Chamoli
Uphar Chamoli
SWStephen Wroe
Stephen Wroe
Various patterns of internal fixation of mandibular condyle fractures have been proposed in the literature. This study investigates the stability of two patient-specific implants (PSIs) for the open reduction and internal fixation of a subcondylar fracture of the mandible. A subcondylar fracture of a mandible was simulated by a series of finite element models. These models contained approximately 1.2 million elements, were heterogeneous in bone material properties, and also modeled the muscles of mastication. Models were run assuming linear elasticity and isotropic material properties for bone. The stability and von Mises stresses of the simulated condylar fracture reduced with each of the PSIs were compared. The most stable of the plate configurations examined was PSI 1, which had comparable mechanical performance to a single 2.0 mm straight four-hole plate.

Verified
Journal Article
Open access
PAPeter Aquilina
Peter Aquilina
WPWilliam C.H. Parr
William C.H. Parr
UCUphar Chamoli
Uphar Chamoli
SWStephen Wroe
Stephen Wroe
PCPhilip Clausen
Philip Clausen
The most stable pattern of internal fixation for mandibular condyle fractures is an area of ongoing discussion. This study investigates the stability of three patterns of plate fixation using readily available, commercially pure titanium implants. Finite element models of a simulated mandibular condyle fracture were constructed. The completed models were heterogeneous in bone material properties, contained approximately 1.2 million elements and incorporated simulated jaw adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. No human subjects were involved in this investigation. The stability of the simulated condylar fracture reduced with the different implant configurations, and the von Mises stresses of a 1.5-mm X-shaped plate, a 1.5-mm rectangular plate, and a 1.5-mm square plate (all Synthes (Synthes GmbH, Zuchwil, Switzerland) were compared. The 1.5-mm X plate was the most stable of the three 1.5-mm profile plate configurations examined and had comparable mechanical performance to a single 2.0-mm straight four-hole plate. This study does not support the use of rectangular or square plate patterns in the open reduction and internal fixation of mandibular condyle fractures. It does provide some support for the use of a 1.5-mm X plate to reduce condylar fractures in selected clinical cases.