The ID10 beamline of the SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) synchrotron light source in Jordan was inaugurated in June 2023 and is now open to scientific users. The beamline, which was designed and installed within the European Horizon 2020 project BEAmline for Tomography at SESAME (BEATS), provides full-field X-ray radiography and microtomography imaging with monochromatic or polychromatic X-rays up to photon energies of 100 keV. The photon source generated by a 2.9 T wavelength shifter with variable gap, and a double-multilayer monochromator system allow versatile application for experiments requiring either an X-ray beam with high intensity and flux, and/or a partially spatial coherent beam for phase-contrast applications. Sample manipulation and X-ray detection systems are designed to allow scanning samples with different size, weight and material, providing image voxel sizes from 13 µm down to 0.33 µm. A state-of-the-art computing infrastructure for data collection, three-dimensional (3D) image reconstruction and data analysis allows the visualization and exploration of results online within a few seconds from the completion of a scan. Insights from 3D X-ray imaging are key to the investigation of specimens from archaeology and cultural heritage, biology and health sciences, materials science and engineering, earth, environmental sciences and more. Microtomography scans and preliminary results obtained at the beamline demonstrate that the new beamline ID10-BEATS expands significantly the range of scientific applications that can be targeted at SESAME.
The main aim of this study is the concept of the magnet holder for the THz undulator utilized in the PolFEL superradiant light source. To achieve maximum flux at high K values (radiation frequencies ranging from 0.5 THz to 5 THz, and K values exceeding 3), it is necessary to use large permanent magnets with dimensions of 100 × 100 × 39.9 mm. For the above assumptions and parameters and specific requirements for magnet positioning, existing design solutions in the literature were found to be insufficient. The main challenges in the design of this holder included the following: (a) the unusually large size of the magnets, (b) requirements of wide-range calibration, and (c) large magnetic forces acting on each magnet, which can approach almost 4 kN. Taking into consideration these challenges, the prototype of the magnet holder was developed and manufactured. The paper presents the findings from both numerical and experimental studies aimed at validating the mechanical behavior and deformation of the proposed magnet holder. The measurements were conducted using two methods—traditional with the use of dial indicators and a novel approach based on the application of the Digital Image Correlation. The results from these numerical and experimental studies indicate that all specified requirements have been satisfactorily met. The study confirms the capability for accurate magnet positioning, demonstrating stable deformation of the holder under a magnetic load. Additionally, it was proved that the positioning of the magnets is both linear and repeatable, with calibration achievable within a range of at least ±0.25 mm.