Jenna Shepherd

Jenna Shepherd


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SBSamuel Briggs-Price
Samuel Briggs-Price
JMJitendra Mangwani
Jitendra Mangwani
LHLinzy Houchen-Wolloff
Linzy Houchen-Wolloff
GMGayatri Modha
Gayatri Modha
EFEmma Fitzpatrick
Emma Fitzpatrick
SOSeth O’neill
Seth O’neill
Background: Achilles tendon rupture (ATR) account for 10.7% of all tendon and ligament injuries and causes lasting muscular deficits and have a profound impact on patients’ quality of life. The incidence, characteristics and management of ATR in the United Kingdom (UK) is poorly understood. This investigation aims to understand the incidence of ATR in the UK. Methods: Prospective data collection of ATR incidence from a United Kingdom Emergency department. Retrospective review of management protocols and immobilisation duration from electronic medical records. Results: ATR incidence is 8 per 100,000 people per annum. Participants were predominately male (79.2%) and primarily reported a sporting mechanism of injury (65.2%). Mean immobilisation duration was 63.1 days. 97.1% were non-surgically managed post ATR. 46.2% of participants had experienced a previous ATR or Achilles tendinopathy prior to their current ATR. Conclusion: The incidence of ATR found was 8. cases per 100,000 people per annum. Most ATR were managed non-surgically in this cohort. The majority of ruptures occurred during sporting activity. Almost one quarter (23.3%) of individuals report Achilles pain prior to ATR.

31 August 2023 in Shoulder & Elbow
Verified
Journal Article
Closed access
JSJenna Shepherd
Jenna Shepherd
SHS Hansjee
S Hansjee
PDP Divall
P Divall
PRP Raval
P Raval
HSHp Singh
Hp Singh
Background: Shoulder range of motion (ROM) is traditionally measured using universal goniometry. However, novel devices to measure shoulder ROM digitally are becoming increasingly available. We aimed to synthesise the current evidence to answer: 1) what technologies are currently in use? 2) Are they reliable? 3) How do they compare to goniometry? Methods: Systematic review of the literature was conducted according to PRISMA guidelines. MEDLINE, Embase, CINAHL, Emcare and Cochrane databases were searched to identify studies comparing a digital device measuring shoulder ROM to goniometry in participants > = 18years. Quality of studies was assessed using COSMIN risk of bias tool. End points included device validity compared to goniometry and intra-rater reliability. Results: 15 articles were included, representing 372 participants and 608 shoulders, and reporting data for five device categories; infrared/RGB-D, 3D-motion-analysis, combined 3D/infra-red, 2D-video-analysis and virtual-reality. Nine studies reported mean bias and 95% limits of agreement (LOA) compared to goniometry. Pooled mean bias was −0.25 degrees (−1.25, 0.75 95% LOA, random effects model) overall. This did not differ by device type (p = 0.83), sensor or non-sensor-based devices (p = 0.62) or plane of movement (p = 0.91). Conclusions: These devices compare well to goniometry and represent a possible means of increasing efficiency and facilitating telemedicine.

28 November 2023 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
SKSherif Ahmed Kamel
Sherif Ahmed Kamel
JSJenna Shepherd
Jenna Shepherd
AAAwf Al-Shahwani
Awf Al-Shahwani
EAEslam Abourisha
Eslam Abourisha
DMDivine Maduka
Divine Maduka
HSHarvinder Singh
Harvinder Singh

11 March 2024 in Injury
Verified
Journal Article
Closed access
MAM. Antonik
M. Antonik
SSS. Sankar
S. Sankar
JSJenna Shepherd
Jenna Shepherd
SHS. Hassan
S. Hassan

12 March 2024 in JVS-Vascular Insights
Verified
Journal Article
Open access
JSJenna Shepherd
Jenna Shepherd
ASAthanasios Saratzis
Athanasios Saratzis
CPCoral Pepper
Coral Pepper
HSHarvinder Singh
Harvinder Singh
SMSarah Jane Messeder
Sarah Jane Messeder
Proximal humerus fractures are common with a reported neurovascular injury incidence of 0.09% to 5%. This study aimed to synthesize the current evidence on the presentation and management of proximal humerus fractures with associated vascular injury to aid clinical decision-making. A systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines (PROSPERO registration: CRD42023393957) to identify articles reporting proximal humerus fractures with associated vascular injury in adults. Study quality was assessed using the Joanna Briggs Institute critical appraisal tools checklist. Outcomes included presentation, fracture classification, type of vascular injury, method of orthopedic and vascular repair, and complications. A total of 40 articles representing 55 individuals with a fracture were included. Injuries most commonly occurred after a low-energy mechanism such as a fall from a standing height (n = 32, 58%). The presentation of ischemia included cool limb (n = 29, 53%), pallor (n = 21, 38%), prolonged capillary refill (n = 7, 13%), and an absent or reduced pulse (n = 47, 85%). Concomitant neurological injury was reported in 30 cases (55%) and fracture dislocations were reported in 17 cases (32.7%). Fracture classification was variable; however, when all recorded fracture patterns were described in terms of 2-, 3-, or 4-part fractures, these represented 49% (n = 27), 24% (n = 13), and 18% (n = 10), respectively. Fracture management preceded vascular repair in 30 (55%). Orthopedic management was primarily performed by open reduction internal fixation or wire fixation (n = 33, 60%) and hemiarthroplasty (n = 11, 20%). Isolated arterial injury was the most common vascular injury (n = 52, 95%). Arterial injuries were primarily repaired by an interposition graft (n = 21, 38%), primary repair (n = 11, 20%), or conservative management (n = 9, 16%). Complications such as amputation, compartment syndrome, avascular necrosis, and metalwork failure were reported in 13 cases. Proximal humerus fractures with associated vascular injuries occur most commonly in the older adults after low-energy mechanisms such as a fall from a standing height. A high index of suspicion is needed as not all injuries present with classical ischemic symptoms, and these injuries carry significant associated morbidity. (JVS-Vascular Insights 2024;2:100065.)

1 October 2021 in The Surgeon
Verified
Journal Article
Closed access
CMChristopher Munro
Christopher Munro
SBSantosh Baliga
Santosh Baliga
JSJenna Shepherd
Jenna Shepherd
CMCampbell F. MacEachern
Campbell F. MacEachern