Zdenek Matej

Prof. Dr. Zdenek Matej

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2019 in Journal of Nuclear Engineering and Radiation Science
Verified
Journal Article
Closed access
PDF file
MKMichal Košťál
Michal Košťál
ZMZdenek Matej
Zdenek Matej
FMFilip Mravec
Filip Mravec
FCFrantišek Cvachovec
František Cvachovec
MSMartin Schulc
Martin Schulc
LVLadislav Viererbl
Ladislav Viererbl
With increasing needs of neutron detection in energy and homeland security sectors, there is an aim in the development of new suitable detection materials with possible n/g separation and also satisfactory resolution. This issue is connected with a well-defined neutron field. The neutron standards 252Cf(spontaneous fission) and 235U(nth fission) have smooth spectra; thus, the tests in these fields can be used for testing of neutron gamma pulse shape discrimination (PSD), but cannot reveal possible problems in the deconvolution. New neutron field which is formed from fission spectrum filtered by 1 m thick silicon block was developed in Research Center Rez. Due to the course of the silicon cross section, the well-distinguished neutron peaks occur in filtered neutron spectrum. In this field, various scintillation materials, HIDEX Aqualight, and EJ299-33A were tested.

12 May 2022 in Quantum Beam Science
Verified
Journal Article
Open access
PDF file
JJJaroslav Jansky
Jaroslav Jansky
JJJiri Janda
Jiri Janda
MKMichal Košťál
Michal Košťál
ZMZdenek Matej
Zdenek Matej
TBTomáš Bílý
Tomáš Bílý
FCFrantišek Cvachovec
František Cvachovec
Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component scintillators to mono-energetic neutron radiation and to determine their light output function, which is necessary for proper neutron energy spectra determination. Both scintillators are composed of the solvent di-iso-propyl-naphthalene (DIPN) mixed isomers. The first scintillator, labeled PYR5/DIPN, contains the luminophore 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline with a concentration of 5 g/L. The second scintillator labeled THIO5/DIPN contains the luminophore 2,5-bis(5-tert-butyl-benzoxazol-2-yl)thiophene also with a concentration of 5 g/L. The responses to neutron energies of 1.5 MeV, 2.5 MeV, and 19 MeV are measured at PTB in Braunschweig. The responses to neutron energies of 2.45 MeV and 14 MeV were measured at CTU in Prague using DD and DT reactions. The responses to a silicon filtered beam were measured at Research Centre Řež. The measurements were processed using a two-parameter spectrometric system NGA-01 to discriminate neutrons from gamma rays. The obtained responses are dominated by recoil protons from elastic collisions of neutrons with hydrogen atoms. The edge of the response of recoil protons gives information about the light output of neutrons, compared to gamma rays for the same radiation energy. The light output function for protons in the PYR5/DIPN scintillator is L(Ep)=0.6294Ep−1.00(1−exp(−0.4933Ep0.95)). The light output function for protons in the THIO5/DIPN scintillator is L(Ep)=0.6323Ep−1.00(1−exp(−0.4986Ep0.9883)). The light output functions well resemble the standard shape, and they are quite similar to each other. That suggests a weak influence of the luminophore on the light output function. The light output functions are ready to be incorporated to the response matrix for the neutron energy spectra determination.

19 February 2021 in Journal of Nuclear Engineering and Radiation Science
Verified
Journal Article
Closed access
PDF file
VJVlastimil Juříček
Vlastimil Juříček
MKMichal Košťál
Michal Košťál
ELEvžen Losa
Evžen Losa
TCTomáš Czakoj
Tomáš Czakoj
ZMZdenek Matej
Zdenek Matej
VRVojtěch Rypar
Vojtěch Rypar
This paper summarizes the issue of the validation of the silicon-filtered neutron beam transport in the deep neutron transport penetration experiment in iron. Iron is an essential structural material important for nuclear technology. The use of a silicon-filtered beam is a very interesting method because some significant peaks occur in the spectrum, helping to study selected wide energy regions during the deep neutron transport in the iron. The detailed characterization of the silicon-filtered beam has been performed in the past as well. Therefore, the input spectrum for the penetration experiments is well-known. The character of the input spectrum is reflecting the fine structure of the silicon cross section in region 1–8 MeV. Based on the agreement between calculated and measured attenuation in groups located within the neutron flux peaks, one can reveal possible problems in neutron transport description. The results are confirming satisfactory agreement of neutron transport description in ENDF/B-VII.1 in the majority of energy regions, while in the interval 4.7–6 MeV, underprediction in attenuation can be observed. This seems to be a consequence of discrepancies in the angular distribution of scattered neutrons. These results constitute an advance to previously performed integral experiments characterizing the neutron transport in iron using 252Cf(s.f) and 235U(nth;fiss).