Background: Lymphoma is the most common spinal cord neoplasm and second most common intracranial tumor in cats, but description of specific magnetic resonance imaging (MRI) features is lacking. Objective: Describe the clinical and MRI features of lymphoma affecting the central (CNS) or peripheral (PNS) nervous system or both in cats. Animals: Thirty-one cats with confirmed cytological or histopathological diagnosis or both of lymphoma involving the CNS or PNS or both, and MRI findings of the lesions. Methods: Multicenter retrospective descriptive study. Signalment and medical information were recorded. Magnetic resonance imaging findings were reviewed by 3 observers following a list of predefined criteria and consensus was sought. Frequency distributions of the different categorical data were reported. Results: Median duration of clinical signs at time of presentation was 14 days (range, 1-90). Neurological examination was abnormal in 30/31 cats. On MRI, lesions affecting the CNS were diagnosed in 18/31 cats, lesions in both CNS and PNS in 12/31, and lesions in the PNS only in 1/31. Intracranial lesions were diagnosed in 22 cats (extra-axial, 7/22; intra-axial, 2/22; mixed, 13/22), and spinal lesions were diagnosed in 12 (6/12 involving the conus medullaris and lumbosacral plexuses). Infiltration of adjacent extra-neural tissue was present in 11/31 cases. Contrast enhancement was seen in all lesions, being marked in 25/30. Meningeal enhancement was present in all but 2 cases. Several distinct MRI patterns were observed. Conclusions and Clinical Importance: Nervous system lymphoma in cats has a wide range of MRI features, of which none is pathognomonic. However, together with clinical data and cerebrospinal fluid (CSF) analysis, MRI may provide a strong tentative antemortem diagnosis.
Computed tomography in standing horses has revolutionized diagnostic imaging. The O-arm®, a cone beam computed tomography (CBCT) scanner with a gantry opening of 96.5 cm is routinely used for image-guided spine and neurosurgery in humans. The aim of this study is to describe the set-up and first experiences using the O-arm® to achieve CBCT imaging of the head in standing horses. CT imaging of the predefined region of interest (ROI) was tested on 2 cadaveric heads, concentrating on centering issues within the gantry, as well as determining the number of scans needed per ROI. All horses presented with head-related diseases and subjected to a CBCT examination between February 2015 and November 2016 for CBCT were included. Per scan, a limited field of view, i.e. a cylindrical volume of 21 cm in diameter and 16 cm in height was acquired within 13 s. Depending on the dimensions of the ROI, the minimum number of scans could range from one to six, if the entire equine head is to be examined in an adult horse. Sixty-eight horses were included, five of which had a follow-up CBCT exam, and two of which were presented twice for two different indications (75 clinical cases). A total number of 449 acquired three-dimensional (3D) scans were recorded for these 75 cases. Two-hundred and forty-two 3D scans (54%) were considered as diagnostic quality. The imaging procedure was generally well tolerated by the sedated, standing equid, and diagnostic studies were performed in 73 out of 75 cases (97.3%). Motion artefacts and inadequate centering of the ROI were the most common reasons for non-diagnostic quality images and repeat scans of the same ROI. CBCT is a valuable imaging modality for the equine head. Advantages of the O-arm® compared to a conventional multi-slice helical CT for imaging of the head in standing equids include the rapid image acquisition, the gantry’s mobility in all dimensions, and the free movability of the entire imaging unit. Disadvantages include the considerable sensitivity to motion artefact, increased scatter, low soft tissue contrast and the limited dimensions of the field of view.
15 February 2018 in Frontiers in Veterinary Science
Muscle signal alteration detected on MRI is seen in diverse pathologic conditions. We observed signal alterations within the paraspinal muscles in dogs with acute thoracolumbar intervertebral disk extrusion. The aim of this retrospective study was to describe MRI features of paraspinal muscle signal alteration in dogs with acute thoracolumbar intervertebral disk extrusion and to investigate an association of the signal alterations with neurological grade, type and location of intervertebral disk extrusion, degree of spinal cord compression, and presence of epidural hemorrhage. Medical records of dogs undergoing MRI because of thoracolumbar intervertebral disk extrusion between August 2014 and June 2016 were reviewed. MRI was evaluated for SI changes within the paravertebral musculature, their location, extension, affected muscles, contrast enhancement, and signal void in T2* sequences. Intervertebral disk herniation was categorized as acute non-compressive nucleus pulposus extrusion (ANNPE) or compressive intervertebral disk disease. In five patients, muscle biopsies of areas with signal intensity changes were taken during surgery. In total, 103 dogs were enrolled in the study. Paraspinal muscle signal alterations were visible in 37 dogs (36%) affecting the epaxial musculature (n = 17), hypaxial musculature (n = 12), or both (n = 8). All signal alterations were hyperintense on T2-weighted images and iso- or hypointense in T1-weighted images. Signal void in T2* was not observed in any dog. Postcontrast sequences were available in 30 of the 37 dogs and showed enhancement in 45%. There was neither an association with degree of compression nor epidural hemorrhage. Intervertebral disk extrusion caudal to L1 and a higher neurological grade was associated with the presence of muscle changes. Histopathology revealed mild to moderate acute muscle fiber degeneration with edema and necrosis in three of five samples. The MRI, as well as the muscle samples, show rather unspecific changes. The underlying pathomechanism might be related to ischemia or muscle spasm, but also denervation edema may explain the signal alteration.
4 December 2020 in Journal of Veterinary Internal Medicine
Background: Cerebrospinal fluid (CSF) flow in disease has been investigated with two-dimensional (2D) phase-contrast magnetic resonance imaging (PC-MRI) in humans. Despite similar diseases occurring in dogs, PC-MRI is not routinely performed and CSF flow and its association with diseases is poorly understood. Objectives: To adapt 2D and four-dimensional (4D) PC-MRI to dogs and to apply them in a group of neurologically healthy dogs. Animals: Six adult Beagle dogs of a research colony. Methods: Prospective, experimental study. Sequences were first optimized on a phantom mimicking small CSF spaces and low velocity flow. Then, 4D PC-MRI and 2D PC-MRI at the level of the mesencephalic aqueduct, foramen magnum (FM), and cervical spine were performed. Results: CSF displayed a bidirectional flow pattern on 2D PC-MRI at each location. Mean peak velocity (and range) in cm/s was 0.92 (0.51-2.08) within the mesencephalic aqueduct, 1.84 (0.89-2.73) and 1.17 (0.75-1.8) in the ventral and dorsal subarachnoid space (SAS) at the FM, and 2.03 (range 1.1-3.0) and 1.27 (range 0.96-1.82) within the ventral and dorsal SAS of the cervical spine. With 4D PC-MRI, flow velocities of >3 cm/s were visualized in the phantom, but no flow data were obtained in dogs. Conclusion: Peak flow velocities were measured with 2D PC-MRI at all 3 locations and slower velocities were recorded in healthy Beagle dogs compared to humans. These values serve as baseline for future applications. The current technical settings did not allow measurement of CSF flow in Beagle dogs by 4D PC-MRI.
Transiently increased teat wall thickness in response to machine milking has been documented by various methods, including ultrasound. However, correlative ultrasonography and histology to detect the origin of this phenomenon is lacking. The first goal of the present study was to evaluate and compare milking-related changes of the teat tissue in 2 breeds of dairy cows (11 Simmental and 3 Holstein) using B-mode ultrasonography. Additionally, the observed changes were compared with ultrasonographic findings in a Holstein cow with periparturient udder edema. Finally, corresponding histological sections of the Simmental teats were analyzed and compared with those from a lactating nonmilked Angus cow. We hypothesized that the mechanical load of both stretching by the vacuum during phases of open teat cup liner and compression by the closed liner during machine milking results in a transient congestion of blood vessels in the teat wall. The barrel of 1 front teat of each cow was scanned immediately before and after machine milking (system vacuum: 42 kPa; pulsation rate: 60 cycles/min; pulsation ratio: 65:35). Shortly after milking (33 ± 6 min), the Simmentals were slaughtered, and their scanned teat was immediately removed and processed for investigation by light microscopy. Ultrasonography after milking revealed anechoic tubular structures mainly in the inner half of the teat wall. Histological examination revealed these structures to be thick-walled veins. The left front and hind teats of the nonmilked lactating cow, collected and prepared identically to those from the Simmental cows, showed the same histological features. Ultrasonographic measurements showed that the diameter of these veins significantly increased after milking compared with matching images before milking. This effect was most pronounced in the Holstein cows. Similarly, these veins were very prominent in the periparturient cow. However, neither the milked cows, including the periparturient cow, nor the lactating nonmilked cow provided any evidence of edematous extravasation on ultrasonography or histology. These findings corroborated our hypothesis that the increase in size of thick-walled veins in the teat tissue is the main reason for the thickening of the teat walls in response to machine milking.
10 November 2022 in Journal of Veterinary Internal Medicine
Background: Oligodendroglioma (OG) accounts for 22% of primary brain tumors in dogs. Oligodendroglioma in dogs is graded as low-grade (II) or high-grade (III), based on the presence of microvascular proliferation and necrosis. Objective: To investigate if magnetic resonance imaging (MRI) features differ between OG II and III in dogs. Animals: Thirty-two dogs with histological diagnosis of intracranial OG and MRI. Methods: Retrospective descriptive study. Histology was reviewed to grade OG according to the revised classification. Brain MRI results were reviewed following criteria including contrast enhancement (CE) pattern, presence of cystic structures, gradient-recalled-echo (GRE) signal voids, and necrosis based on signal intensity, as well as diffusion-weighted imaging characteristics. The MRI features were compared between OG II and III using Fisher's exact tests and logistic regression models. Results: Histology identified 8 dogs with OG II (25%) and 24 with OG III (75%). All OG III showed moderate-to-marked CE including 18/24 (75%) with a ring pattern. These features were not seen in OG II. Heterogeneity, cystic structures, GRE signal voids, and necrosis were associated with OG III. No difference in diffusion characteristics was detected between OG II and III. Conclusion and Clinical Importance: Moderate-to-marked CE and ring pattern were present in dogs with OG III but not in OG II. The presence of cystic structures, GRE signal voids, and necrosis was strongly associated with OG III. Although the importance of brain tumor grading in dogs with regard to prognosis and treatment options remains unknown, the results indicate that MRI reflects the histological features used for grading OG in dogs.