Ilesh Jani

Dr. Ilesh Jani

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2011 in The Lancet
Verified
Journal Article
Closed access
IJIlesh Jani
Ilesh Jani
NSNádia E Sitoe
Nádia E Sitoe
EAEunice R Alfai
Eunice R Alfai
PCPatrina L Chongo
Patrina L Chongo
JQJorge I Quevedo
Jorge I Quevedo
TPTrevor F Peter
Trevor F Peter

13 June 2013 in New England Journal of Medicine
Verified
Journal Article
Closed access
IJIlesh Jani
Ilesh Jani
TPTrevor F. Peter
Trevor F. Peter
In areas of limited resources, point-of-care diagnostic testing is being increasingly used to identify disease, determine prognosis, and monitor treatment. Investments in new diagnostics are starting to improve care. Health systems need to evolve to reap benefits for global health.

16 May 2008 in BMC Public Health
Verified
Journal Article
Open access
PDF file
JJJagrati V Jani
Jagrati V Jani
CSCaroline De Schacht
Caroline De Schacht
IJIlesh Jani
Ilesh Jani
GBGunnar Bjune
Gunnar Bjune
Inadequate levels of immunization against childhood diseases remain a significant public health problem in resource-poor areas of the globe. Nonetheless, the reasons for incomplete vaccination and non-uptake of immunization services are poorly understood. This study aimed at finding out the reasons for non-vaccination and the magnitude of missed opportunities for vaccination in children less than two years of age in a rural area in southern Mozambique.

15 April 2002 in Cytometry
Verified
Journal Article
Open access
PDF file
DGDeborah Glencross
Deborah Glencross
LSLesley E. Scott
Lesley E. Scott
IJIlesh Jani
Ilesh Jani
DBDavid Barnett
David Barnett
GJGeorge Janossy
George Janossy
BACKGROUND: North American and European guidelines for dual‐platform (DP) flow cytometry recommend absolute CD4 T‐cell counts to be calculated from two parameters: the absolute lymphocyte counts obtained on a hematology analyzer and the percentages of CD4+ cells among lymphocytes (CD4%/lympho) obtained by flow cytometry. Nevertheless, the identification of lymphocytes is error‐prone: a poor match between these common denominators in the two systems is the main source of inaccuracy. In contrast, total leucocyte counts (white cell counts [WCC]) and CD4% among the gated CD45+ leucocytes (CD4%/leuco) can be determined with greater accuracy. Methods: We introduced “PanLeucogating,” i.e., we used total leucocytes as the common denominator for improving the precision of DP absolute CD4 counting. Correlations and Bland‐Altman tests were used for statistical analysis. Results: First, 22 stabilized blood product samples were provided by U.K. National External Quality Assessment Scheme (NEQAS) and a higher accuracy and precision of CD4 counts were documented using PanLeucogating compared with lymphocyte gating. Next, 183 fresh and 112 fixed (TransFix) whole blood samples were used to compare DP methods and single‐platform (SP) methodology, including both volumetric and bead‐based techniques. A particularly high correlation and comparable precision of absolute CD4 counts were observed between the SP volumetric method and DP PanLeucogating (R2 = 0.990; bias 6 ± SD 17%). The SP volumetric method showed lower levels of agreement with the DP lymphocyte gating (R2 = 0.758; bias 14 ± SD 51%) and with the SP bead‐based method (R2 = 0.923; bias 4 ±SD 31%). Conclusions: These observations show that DP leucocyte counts (WCC) should replace lymphocyte counts as the “common denominator” although CD4%/lympho values can, as an extra step, be also provided readily if requested. When coupled with quality control for WCC on hematology analyzers, the DP method with CD45 PanLeucogating represents a robust CD4 T‐cell assay that is as accurate as the SP volumetric technique. This DP method uses only two, CD45 and CD4, antibody reagents and can be run on any pair of hematological analyzer plus flow cytometer. Cytometry (Clin. Cytometry) 50:69–77, 2002.

27 March 2011 in AIDS
Verified
Journal Article
Closed access
IJIlesh Jani
Ilesh Jani
NSNádia E Sitoe
Nádia E Sitoe
PCPatrina L Chongo
Patrina L Chongo
EAEunice R Alfai
Eunice R Alfai
JQJorge I Quevedo
Jorge I Quevedo
TPTrevor F Peter
Trevor F Peter
To evaluate the accuracy of point-of-care tests (POCTs) for CD4 cell, clinical chemistry and hemoglobin in primary healthcare clinics in Mozambique. POCT and laboratory-based assays were conducted on adult HIV-positive patients enrolled consecutively at primary healthcare clinics in Mozambique. Patients were tested on-site with POCT CD4 (Pima), clinical chemistry (Reflotron) and hemoglobin (HemoCue) devices using finger prick blood. Results obtained on paired blood samples were used for agreement analysis (bias and limits of agreement). Repeatability analysis was also performed for POCT CD4 cell counting. Primary health nurses operating the Pima, Reflotron and HemoCue POCT devices produced results with low levels of bias for CD4+ T-cell counts (−52.8 cells/μl), alanine aminotransferase (−0.2 U/l), aspartate aminotransferase (−4.0 U/l) and hemoglobin (0.95 g/dl). CD4+ T-cell counts in paired specimens of finger prick and venous blood tested on the POCT CD4 device were in close agreement (bias −9 cells/μl, coefficient of variation 10.6%). The repeatability of POCT CD4 cell counting was similar to that observed with laboratory instruments (bias −6.2 cells/μl, coefficient of variation 10.7% vs. bias −5.7 cells/μl, coefficient of variation 7.5%). Primary health clinic nurses generated accurate results for CD4+ T-cell counts, liver enzymes and hemoglobin using simple POC devices on finger prick samples at decentralized antiretroviral therapy (ART) clinics. POC diagnostics to monitor ART at primary healthcare level is technically feasible and should be utilized in efforts to decentralize HIV care and treatment.

1 September 2014 in JAIDS Journal of Acquired Immune Deficiency Syndromes
Verified
Journal Article
Closed access
IJIlesh Jani
Ilesh Jani
BMBindiya Msc Meggi
Bindiya Msc Meggi
NMNédio Msc Mabunda
Nédio Msc Mabunda
AVAdolfo Msc Vubil
Adolfo Msc Vubil
NSNadia E. Msc Sitoe
Nadia E. Msc Sitoe
TPTrevor F. Peter
Trevor F. Peter
Objective: To evaluate the accuracy of a point-of-care (POC) nucleic acid–based test (NAT) for early infant HIV diagnosis (EID) in primary health clinics in Mozambique. Methods: POC and laboratory NAT EID tests were conducted on matched blood samples collected from 827 HIV-exposed infants younger than 18 months who were enrolled consecutively at 4 periurban primary health clinics and the central hospital in Maputo. Lancet heel draw blood collected by nurses was tested on site for HIV-1/-2 RNA on the Alere HIV NAT POC device and also used to create dried blood spots for later laboratory EID testing on the Roche Cobas Taqman/Ampliprep instrument. Results were used to determine the sensitivity, specificity, and agreement between the POC and laboratory NAT EID tests. Results: The sensitivity and specificity of POC NAT EID testing were 98·5% (95% confidence interval (CI): 91.7 to 99.9, n = 65) and 99·9% (95% CI: 99.3 to 100, n = 762), respectively, compared with laboratory EID tests. Overall agreement was high (Cohen kappa = 0·981; 95% CI: 0.96 to 1.00). Positive (98·5%; 95% CI: 96·3 to 100) and negative 99.9% (95% CI: 99.7 to 100) test agreement was also high. Conclusions: Primary health care nurses accurately performed POC NAT EID testing within primary health care clinics. On-site nucleic acid–based EID testing is technically feasible in clinic settings and could be used in efforts to improve access to pediatric HIV antiretroviral treatment.