Liquid-based perinatal life support (PLS) technology will probably be applied in a first-in-human study within the next decade. Research and development of PLS technology should not only address technical issues, but also consider socio-ethical and legal aspects, its application area, and the corresponding design implications. This paper represents the consensus opinion of a group of healthcare professionals, designers, ethicists, researchers and patient representatives, who have expertise in tertiary obstetric and neonatal care, bio-ethics, experimental perinatal animal models for physiologic research, biomedical modeling, monitoring, and design. The aim of this paper is to provide a framework for research and development of PLS technology. These requirements are considering the possible respective user perspectives, with the aim to co-create a PLS system that facilitates physiological growth and development for extremely preterm born infants.
Importance: Real-time electrohysterography (EHG)–based technologies have recently become available for uterine monitoring during term labor. Therefore, obstetricians need to be familiar with the diagnostic value, advantages, and limitations of using EHG. Objective: The aims of this study were to determine the diagnostic value of EHG in comparison to (1) the intrauterine pressure catheter (IUPC), (2) the external tocodynamometer (TOCO), and (3) in case of maternal obesity; (4) to evaluate EHG from users' and patients' perspectives; and (5) to assess whether EHG can predict labor outcome. Evidence Acquisition: A systematic review was performed in the MEDLINE, EMBASE, and Cochrane library in October 2017 resulting in 209 eligible records, of which 20 were included. Results: A high sensitivity for contraction detection was achieved by EHG (range, 86.0%–98.0%), which was significantly better than TOCO (range, 46.0%–73.6%). Electrohysterography also enhanced external monitoring in case of maternal obesity. The contraction frequency detected by EHG was on average 0.3 to 0.9 per 10 minutes higher compared with IUPC, which resulted in a positive predictive value of 78.7% to 92.0%. When comparing EHG tocograms with IUPC traces, an underestimation of the amplitude existed despite that patient-specific EHG amplitudes have been mitigated by amplitude normalization. Obstetricians evaluated EHG tocograms as better interpretable and more adequate than TOCO. Finally, potential EHG parameters that could predict a vaginal delivery were a predominant fundal direction and a lower peak frequency. Conclusions and Relevance: Electrohysterography enhances external uterine monitoring of both nonobese and obese women. Obstetricians consider EHG as better interpretable; however, they need to be aware of the higher contraction frequency detected by EHG and of the amplitude mismatch with intrauterine pressure measurements. Target Audience: Obstetricians and gynecologists, family physicians. Learning Objectives: After completing this activity, the learner should be better able to interpret the physiology of uterine contractions, relate the diagnostic value of electrohysterography (EHG) traces to intrauterine pressure catheter and tocodynamometer, examine how the performance of the external uterine monitoring techniques is affected by maternal obesity, distinguish the advantages and limitations of EHG-based monitoring from users' and patients' perspectives, and propose uses for EHG uterine contraction monitoring and other (future) applications of EHG.
Objective : Monitoring of the fetal condition during labor is currently performed by cardiotocograpy (CTG). Despite the use of CTG in clinical practice, CTG interpretation suffers from a high inter- and intra-observer variability and a low specificity. In addition to CTG, analysis of fetal heart rate variability (HRV) has been shown to provide information on fetal distress. However, fetal HRV can be strongly influenced by uterine contractions, particularly during the second stage of labor. Therefore, the aim of this study is to examine if distinguishing contractions from rest periods can improve the detection rate of HRV features for fetal distress during the second stage of labor. Approach : We used a dataset of 100 recordings, containing 20 cases of fetuses with adverse outcome. The most informative HRV features were selected by a genetic algorithm and classification performance was evaluated using support vector machines. Main results : Classification performance of fetal heart rate segments closest to birth improved from a geometric mean of 70% to 79%. If the classifier was used to indicate fetal distress over time, the geometric mean at 15 minutes before birth improved from 60% to 72%. Significance : Our results show that combining contraction-dependent HRV features with HRV features calculated over the entire fetal heart rate signal improves the detection rate of fetal distress.
Background: Every day approximately 810 women die from complications related to pregnancy and childbirth worldwide. Around two thirds of these deaths happen in sub-Saharan Africa. One of the strategies to decrease these numbers is improving the quality of care by emergency obstetric simulation-based training. The effectiveness of such training programs depends on the program’s instructional design. Objective: This review gives an overview of studies about emergency obstetric simulation-based training and examines the applied instructional design of the training programs in sub-Saharan and Central Africa. Methods: We searched Medline, Embase and Cochrane Library from inception to May 2021. Peer-reviewed articles on emergency obstetric, postgraduate, simulation-based training in sub-Saharan and Central Africa were included. Outcome measures were categorized based on Kirkpatrick’s levels of training evaluation. The instructional design was evaluated by using the ID-SIM questionnaire. Findings: In total, 47 studies met the inclusion criteria. Evaluation on Kirkpatrick level 1 showed positive reactions in 18 studies. Challenges and recommendations were considered. Results on knowledge, skills, and predictors for these results (Kirkpatrick level 2) were described in 29 studies. Retention as well as decay of knowledge and skills over time were presented. Results at Kirkpatrick level 3 were measured in 12 studies of which seven studies demonstrated improvements of skills on-the-job. Improvements of maternal and neonatal outcomes were described in fifteen studies and three studies reported on cost-estimations for training rollout (Kirkpatrick level 4). Instructional design items were heterogeneously applied and described. Conclusions: Results of 47 studies indicate evidence that simulation-based training in sub-Saharan and Central Africa can have a positive impact across all four levels of Kirkpatrick’s training evaluation model. However, results were not consistent across all studies and the effects vary over time. A detailed description of instructional design features in future publications on simulation-based training will contribute to a deeper understanding of the underlying mechanisms that determine why certain training programs are more effective in improving maternal and neonatal healthcare outcomes than other.