Vinzenz Ludwig Mayr

Dr. Vinzenz Ludwig Mayr

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2006 in Anaesthesia and Intensive Care
Verified
Journal Article
Open access
PDF file
SJS. Jochberger
S. Jochberger
GLG. Luckner
G. Luckner
VMVinzenz Ludwig Mayr
Vinzenz Ludwig Mayr
VWV. Wenzel
V. Wenzel
NMN. G. Morgenthaler
N. G. Morgenthaler
MDM. W. Dünser
M. W. Dünser
In this case report, the course of arginine vasopressin and copeptin, the stable C-terminal part of the arginine vasopressin precursor, is described during the period of critical illness in a septic shock patient. Arginine vasopressin and copeptin concentrations were substantially increased during the initial 36 hours of shock. Subsequently, both hormones continuously decreased, but exhibited another peak in response to stress during extubation. During restoration of cardiovascular stability, endogenous arginine vasopressin levels further decreased and obviously did not contribute to haemodynamic improvement. In contrast, the decrease in arginine vasopressin and copeptin can be at least partly explained by an improvement of cardiovascular function.

17 December 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
LLLukas Luerken
Lukas Luerken
AGAndrea Goetz
Andrea Goetz
VMVinzenz Ludwig Mayr
Vinzenz Ludwig Mayr
LZLiang Zhang
Liang Zhang
ASAlexandra Schlitt
Alexandra Schlitt
IEIngo Einspieler
Ingo Einspieler
Background and Objectives: To report on the first results of safety, efficacy, and outcome of CT-navigated stereotactic percutaneous electrochemotherapy (SpECT) in patients with primary and secondary liver malignancies. Methods: This retrospective study included 23 consecutive lesions in 22 patients who underwent SpECT for primary and secondary malignant liver lesions with locally curative intention. The endpoints were primary technique efficacy (PTE), local tumor progression (LTP), time to progression (TTP), and occurrence of adverse events. Results: The mean maximum diameter of the treated lesions was 42 mm (range: 16 mm–72 mm). Eight lesions were hepatocellular carcinoma (34.8%), five lesions were colorectal liver metastases (21.7%), three lesions were cholangiocellular carcinoma (13.0%), and the other seven lesions were liver metastases from different primary cancers (30.4%). PTE was achieved for 22 lesions (95.7%). The mean follow-up time was 15 months (0–39 months). No LTP was observed. In six patients (27.3%), hepatic tumor progression was observed during follow-up with a mean TTP of 3.8 months (2–8 months). In 10 procedures (43.5%), minor complications (1 CIRSE Grade 2) and side effects occurred, but no major complications were observed. Conclusions: SpECT seems to be a safe and effective new local treatment modality for primary and secondary liver malignancies.

18 December 2024 in Cancers
Verified
Journal Article
Open access
PDF file
LZLiang Zhang
Liang Zhang
LLLukas Luerken
Lukas Luerken
VMVinzenz Ludwig Mayr
Vinzenz Ludwig Mayr
AGAndrea Goetz
Andrea Goetz
ASAlexandra Schlitt
Alexandra Schlitt
IEIngo Einspieler
Ingo Einspieler
Purpose: To evaluate the efficacy and safety of the Surgnova Dophi™ M150E microwave ablation system in a prospective single-center observational study. Methods: A cohort of 50 patients with 77 primary or secondary liver tumors underwent CT-navigated stereotactic percutaneous microwave ablation with curative intention using the Surgnova Dophi™ M150E system. The endpoints were primary technique efficacy (PTE), number of complications, ablation defect dimensions, and sphericity index compared to previously reported findings. Results: The PTE was 97.4%, with complete ablation in 75 out of 77 tumors. Complications occurred in 10% of patients, with 4% classified as major. A comparison with previous in vivo data confirmed the reliability of the system in achieving reproducible and predictable ablation results. Conclusions: Stereotactic percutaneous microwave ablation with the Surgnova Dophi™ M150E system is safe and effective for liver tumor treatment.

24 November 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
LZLiang Zhang
Liang Zhang
ANAnthony Ngu
Anthony Ngu
LKLaura S. Kupke
Laura S. Kupke
VMVinzenz Ludwig Mayr
Vinzenz Ludwig Mayr
QSQuirin David Strotzer
Quirin David Strotzer
IEIngo Einspieler
Ingo Einspieler
Objective: To evaluate the safety, diagnostic yield, and ablation efficacy of a single-session workflow combining stereotactic percutaneous core-needle biopsy (CNB) immediately followed by microwave ablation (MWA) for liver tumors. Methods: We retrospectively reviewed consecutive patients (December 2021–May 2025) who underwent stereotactic CNB followed by MWA in the same procedure. Primary endpoints were primary technique efficacy (PTE) and complications. Secondary endpoints were 6-month local tumor progression (LTP) and diagnostic yield. Six-month LTP was summarized using a Kaplan–Meier (KM) point estimate with Greenwood 95% CIs. Results: Thirty-three patients underwent single-session biopsy and ablation (33 biopsied; 41 lesions ablated). PTE was 95.1% (39/41); two residual tumors were successfully re-ablated. Six-month LTP was 3.6% (patient level; KM 95% CI 0.0–10.5%) and 2.8% (lesion level; KM 95% CI 0.0–8.2%). There was one major complication (3%, post-ablation abscess) and no minor complications. Adequate tissue was obtained in all biopsies; a definitive diagnosis was established in 88% (29/33): malignancy in 73% (24/33) and benignity in 15% (5/33); 12% (4/33) were nondiagnostic. In the hepatocellular carcinoma (HCC)-suspected subgroup (LI-RADS LR-3 to LR-5; n = 24), all LR-5 lesions were HCC (11/11). Among LR-4 lesions (n = 7), histology showed HCC in 1/7 (14%) and cholangiocarcinoma in 2/7 (29%); 4/7 (57%) were benign or nondiagnostic. Among LR-3 lesions (n = 6), 2/6 (33%) were HCC and 4/6 (67%) were benign or nondiagnostic. In the metastasis-suspected subgroup (n = 9), malignancy was confirmed in 8/9 (89%); 1/9 (11%) was nondiagnostic. Conclusions: Single-session stereotactic CNB followed by MWA is feasible and safe, yields diagnostically useful tissue, and achieves high ablation efficacy.