Bożena Antonowicz

Dr. Bożena Antonowicz


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2017 in Frontiers in Physiology
Verified
Journal Article
Open access
JBJan Borys
Jan Borys
Mateusz MaciejczykMateusz Maciejczyk
Mateusz Maciejczyk
AKAdam J. Krȩtowski
Adam J. Krȩtowski
BABożena Antonowicz
Bożena Antonowicz
Wioletta Ratajczak-WronaWioletta Ratajczak-Wrona
Wioletta Ratajczak-Wrona
Anna ZalewskaAnna Zalewska
Anna Zalewska
Titanium miniplates and screws are commonly used for fixation of fractured or osteotomised jaws. Despite the opinion of their biocompatibility, in clinical practice symptoms of chronic inflammation around the fixation develop in some patients, even many years after the application of miniplates and screws. The cause of these complications is still an open question. Taking into account that oxidative stress is one of the toxic action of titanium, we have evaluated the antioxidant barrier as well as oxidative stress in the erythrocytes, plasma and periosteum covering the titanium fixation of the jaws. The study group was composed of 32 patients aged 20–30 with inserted miniplates and screws. Antioxidant defence: catalase (CAT), glutathione peroxidase (GPx), superoxide dismutase-1 (SOD1), uric acid (UA), total antioxidant capacity (TAC), as well as oxidative damage products: advanced oxidation protein products (AOPP), advanced glycation end products (AGE), dityrosine, kynurenine, N-formylkynurenine, tryptophan, malondialdehyde (MDA), 4-hydroxynonenal (4-HNE), total oxidant status (TOS), and oxidative status index (OSI) were evaluated. SOD1 activity (↓37%), and tryptophan levels (↓34%) showed a significant decrease while AOPP (↑25%), TOS (↑80%) and OSI (↑101%) were significantly elevated in maxillary periosteum of patients who underwent bimaxillary osteotomies as compared to the control group. SOD-1 (↓55%), TAC (↓58.6%), AGE (↓60%) and N-formylkynurenine (↓34%) was statistically reduced while AOPP (↑38%), MDA (↑29%), 4-HNE (↑114%), TOS (↑99%) and OSI (↑381%) were significantly higher in the mandibular periosteum covering miniplates/screw compared with the control tissues. There were no correlations between antioxidants and oxidative stress markers in the periosteum of all patients and the blood. As exposure to the Ti6Al4V titanium alloy leads to disturbances of redox balance in the periosteum surrounding titanium implants of the maxilla and the mandible so antioxidant supplementation should be recommended to the patients undergoing treatment of dentofacial deformities with the use of titanium implants. The results we obtained may also indicate a need to improve the quality of titanium jaw fixations through increase of TiO2 passivation layer thickness or to develop new, the most highly biodegradable materials for their production.

1 January 2018 in Oxidative Medicine and Cellular Longevity
Verified
Journal Article
Open access
PDF file
JBJan Borys
Jan Borys
Mateusz MaciejczykMateusz Maciejczyk
Mateusz Maciejczyk
BABożena Antonowicz
Bożena Antonowicz
AKAdam Krętowski
Adam Krętowski
DWDanuta Waszkiel
Danuta Waszkiel
Anna ZalewskaAnna Zalewska
Anna Zalewska
Due to the high biotolerance, favourable mechanical properties, and osseointegration ability, titanium is the basic biomaterial used in maxillofacial surgery. The passive layer of titanium dioxide on the surface of the implant effectively provides anticorrosive properties, but it can be damaged, resulting in the release of titanium ions to the surrounding tissues. The aim of our work was to evaluate the influence of Ti6Al4V titanium alloy on redox balance and oxidative damage in the periosteum surrounding the titanium miniplates and screws as well as in plasma and erythrocytes of patients with mandibular fractures. The study included 31 previously implanted patients (aged 21–29) treated for mandibular fractures and 31 healthy controls. We have demonstrated increased activity/concentration of antioxidants both in the mandibular periosteum and plasma/erythrocytes of patients with titanium mandibular fixations. However, increased concentrations of the products of oxidative protein and lipid modifications were only observed in the periosteum of the study group patients. The correlation between the products of oxidative modification of the mandible and antioxidants in plasma/erythrocytes suggests a relationship between the increase of oxidative damage at the implantation site and central redox disorders in patients with titanium miniplates and screws.

23 August 2013 in International Journal of Oral Science
Verified
Journal Article
Open access
PDF file
Wioletta Ratajczak-WronaWioletta Ratajczak-Wrona
Wioletta Ratajczak-Wrona
EJEwa Jablonska
Ewa Jablonska
BABożena Antonowicz
Bożena Antonowicz
DDDorota Dziemianczyk
Dorota Dziemianczyk
SGStanislawa Zyta Grabowska
Stanislawa Zyta Grabowska
The aim of the study was a determination of the levels of nitric oxide (NO) and its biological markers such as malonyldialdehyde (MDA) and nitrotyrosine in the serum of patients with squamous cell carcinoma (SCC) of the oral cavity and identification of the relationships between NO and those markers. These studies were performed on patients with SCC of the oral cavity before and after treatment. Griess reaction was used for the estimation of the total concentration of NO in serum. The nitrotyrosine level in serum was assessed with an enzyme-linked immunosorbent assay (ELISA) kit, and MDA level using a spectrophotometric assay. Higher concentrations of NO in blood serum were determined in patients with stage IV of the disease before treatment in comparison to the control group and patients with stages II and III of the disease. Moreover, higher concentrations of MDA and nitrotyrosine were determined in the serum of patients in all stages of the disease in comparison to healthy people. After treatment, lower concentrations of NO in the serum of patients with stage IV of the disease were observed in comparison to the amounts obtained prior to treatment. In addition, lower levels of nitrotyrosine in the serum of patients with all stages of the disease were recorded, whereas higher concentrations of MDA were determined in these patients in comparison to results obtained before treatment. The compounds formed with the contribution of NO, such as MDA and nitrotyrosine, may lead to cancer progression in patients with SCC of the oral cavity, and contribute to formation of resistance to therapy in these patients as well. Moreover, the lack of a relationship between concentrations of NO and MDA, and between NO and nitrotyrosine in serum suggests that the process of lipid peroxidation and nitration in patients with SCC does not just depend on NO.

5 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Zaneta MierzejewskaZaneta Mierzejewska
Zaneta Mierzejewska
BRBartłomiej Rusztyn
Bartłomiej Rusztyn
KŁKamila Łukaszuk
Kamila Łukaszuk
JBJan Borys
Jan Borys
MBMarta Borowska
Marta Borowska
BABożena Antonowicz
Bożena Antonowicz
Recent decades clearly demonstrate the growing use of nanomaterials in medical practice, and their effectiveness is systematically confirmed by the consequent scientific research. An example of the use of nanomaterials in dentistry is endodontic treatment, which, due to its specificity, is one of the most demanding procedures, fraught with numerous challenges, such as difficulties in reaching tooth roots and ineffective cleaning or insufficient sealing of root canals, which may lead to re-infection or damage to adjacent structures. The use of nanomaterials has a positive impact on solving these problems, and the combination of biomaterials with nanometric technology makes endodontic treatment more effective, precise and comfortable for patients, which contributes to improving the quality of dental care. Currently, nanomaterials with a high biocompatibility can be used in endodontics as components of irrigation solutions, for rinsing root canals and as drug carriers for intracanal use. Nanomaterials are also components of sealants filling root canals. However, the latest research shows that reducing the size of materials to the “nano” scale significantly affects their basic physicochemical properties, which leads to increased reactivity and the ability to interact at the molecular level. These unique physicochemical properties, which have contributed to the use of nanomaterials in numerous medical-related solutions, raise concerns and provoke discussions about the safety of their use in direct contact with tissues.

Verified
Journal Article
Open access
PDF file
Anna ZalewskaAnna Zalewska
Anna Zalewska
BABożena Antonowicz
Bożena Antonowicz
JSJulita Szulimowska
Julita Szulimowska
IZIzabela Zieniewska-Siemieńczuk
Izabela Zieniewska-Siemieńczuk
Barbara LeśniewskaBarbara Leśniewska
Barbara Leśniewska
Mateusz MaciejczykMateusz Maciejczyk
Mateusz Maciejczyk
Despite the high biocompatibility of titanium and its alloys, the need to remove titanium implants is increasingly being debated due to the potential for adverse effects associated with long-term retention. Therefore, new solutions are being sought to enhance the biocompatibility of titanium implants. One of them is to increase the thickness of the passive layer of the implant made of titanium dioxide. We were the first to evaluate the effect of hard-anodized (type II) Ti-6Al-4V alloy discs on the cytotoxicity, mitochondrial function, and redox balance of fibroblasts mitochondria compared to standard-anodized (type III) and non-anodized discs. The study used fibroblasts obtained from human gingival tissue. The test discs were applied to the bottom of 12-well plates. Cells were cultured for 24 h and 7, 14, and 21 days and mitochondria were isolated. We demonstrated the occurrence of oxidative stress in the mitochondria of fibroblasts of all tested groups, regardless of the presence and type of anodization. Type II anodization prevented changes in complex II activity (vs. control). The lowest degree of citrate synthase inhibition occurred in mitochondria exposed to titanium discs with type II anodization. In the last phase of culture, the presence of type II anodization reduced the degree of cytochrome c oxidase inhibition compared to the other tests groups and the control group, and prevented apoptosis. Throughout the experiment, the release of titanium, aluminium, and vanadium ions from titanium discs with a hard-anodized passive layer was higher than from the other titanium discs, but decreased with time. The obtained results proved the existence of dysfunction and redox imbalance in the mitochondria of fibroblasts exposed to hard-anodized titanium discs, suggesting the need to search for new materials perhaps biodegradable in tissues of the human body.

Verified
Journal Article
Open access
Zaneta MierzejewskaZaneta Mierzejewska
Zaneta Mierzejewska
VVValentina Veselinovic
Valentina Veselinovic
NTNatasa Trtic
Natasa Trtic
SMSasa Marin
Sasa Marin
JBJan Borys
Jan Borys
BABożena Antonowicz
Bożena Antonowicz
Recent advances in biomaterials, immunomodulation, stem cell therapy, and biofabrication are reshaping maxillofacial surgery, shifting reconstruction paradigms toward biologically integrated and patient-specific tissue regeneration. This review provides a comprehensive synthesis of current and emerging strategies for bone and soft-tissue regeneration in the craniofacial region, with particular emphasis on bioactive ceramics, biodegradable polymers, hybrid composites, and stimuli-responsive smart materials. We further examine translational technologies such as extracellular vesicles, decellularized extracellular matrices, organoids, and 3D bioprinting, highlighting key challenges such as bioink standardization, perfusion limitations, and regulatory classification. Maxillofacial surgery is positioned for a paradigm shift toward personalized, biologically active, and clinically scalable regenerative solutions.