Carlos Eduardo Soto Ramírez

Dr. Carlos Eduardo Soto Ramírez

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
BRBlanca Estela Ríos-González
Blanca Estela Ríos-González
LLLiliana López-Barragán
Liliana López-Barragán
ASAna Miriam Saldaña-Cruz
Ana Miriam Saldaña-Cruz
SMSergio Gabriel Gallardo Moya
Sergio Gabriel Gallardo Moya
Aniel Jessica Leticia Brambila-TapiaAniel Jessica Leticia Brambila-Tapia
Aniel Jessica Leticia Brambila-Tapia
EGElida Berenice García-Calvario
Elida Berenice García-Calvario
Background/Objectives: Some vascular alterations such as peripheral arterial disease (PAD) or arterial stiffness can alter perfusion of the limbs, so we wondered if this is reflected in the temperature of the soles of the feet of diabetic patients who did not have a diagnosis of peripheral arterial disease. Foot sole temperature was correlated with the ankle–brachial index (ABI), carotid—femoral pulse wave velocity (cfPWV), brachial–ankle pulse wave velocity (baPWV), and arterial age. Methods: A total of 175 patients with type 2 diabetes mellitus, without a previous diagnosis of PAD, were recruited. Comorbidities, anthropometry, biochemical analysis results, temperature, ABI, cfPWV, baPWV, and arterial age were recorded. Forty-two temperature records were obtained from the sole of the foot with an FLIR T865 thermal imaging camera. ABI, cfPWV, baPWV, and arterial age were obtained using plethysmographic and oscillometric methods. Statistical analysis was performed with SPSS v.29.0 (correlations and multiple linear regression models). Results: All temperature points analyzed correlated negatively with ABI (p < 0.001) and rho values ranged from −0.168 to −0.210. Likewise, cfPWV, baPWV, and arterial age had similar results, since most temperature records showed low rho values and a negative correlation with these parameters. Four models were developed to explain the variables of interest. Temperature was involved in all of them. The temperature of the first toe was included in the prediction of cfPWV, baPWV, and arterial age. Conclusions: There is an inversely proportional relationship between temperature and ABI, cfPWV, baPWV, and arterial age in diabetic patients without a previous diagnosis of arterial disease. Temperature can be a predictor of these hemodynamic variables.

11 June 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
BRBlanca Estela Ríos-González
Blanca Estela Ríos-González
Aniel Jessica Leticia Brambila-TapiaAniel Jessica Leticia Brambila-Tapia
Aniel Jessica Leticia Brambila-Tapia
CRCarlos Eduardo Soto Ramírez
Carlos Eduardo Soto Ramírez
ASAna Miriam Saldaña-Cruz
Ana Miriam Saldaña-Cruz
AMAlejandra Martínez-Hernández
Alejandra Martínez-Hernández
EGElida Berenice García-Calvario
Elida Berenice García-Calvario
Background: Previous studies have suggested that neuropathy is linked to changes in temperature in the soles of diabetic patients and rats. However, primary care in Mexico is limited. This study explores whether thermography can detect temperature changes in areas with sensitivity alterations (assessed using monofilament testing).Objectives: This study aims to compare the temperature of the soles of diabetic patients with tactile sensitivity alterations against those without such alterations. Additionally, we compared the temperature between non-sensitive and sensitive sites on the feet and finally found a regression model. Methods: A case-control study was conducted involving 116 feet with sensitivity alterations and 116 feet without alterations by the Semmes-Weinstein monofilament (SWM). We performed a comparative cross-sectional analysis of sensitive and non-sensitive sites' temperatures and a logistic regression. Sensitivity was evaluated using the SWM at nine sites. Sensitivity alteration was defined as the inability to detect all tested sites on the sole with SWM. Additionally, pallesthesia was assessed using a 128 Hz tuning fork. The temperature of the soles was measured using a FLIR model T865 thermal imaging camera, capturing minimum, maximum, and mean temperatures in degrees Celsius (°C) across the same nine sites assessed for sensitivity. Results: No significant differences were observed in temperature between cases and controls or between sensitive and non-sensitive sites in patients with diabetes. Logistic regression resulted in a model that included only creatinine. However, the temperature was not associated with the model. Conclusions: The study found no association between sensitivity alterations and temperature in the sole in patients with type 2 diabetes, as determined through SWM testing.