Mohamed Saadeldin

Dr. Mohamed Saadeldin

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2022 in Remote Sensing Applications: Society and Environment
Verified
Journal Article
Open access
MSMohamed Saadeldin
Mohamed Saadeldin
RORob O'Hara
Rob O'Hara
JZJesko Zimmermann
Jesko Zimmermann
BNBrian Mac Namee
Brian Mac Namee
SGStuart Green
Stuart Green

12 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MAMohammed H. AlSharif
Mohammed H. AlSharif
MSMohamed Saadeldin
Mohamed Saadeldin
MSMohamed Siala
Mohamed Siala
MAMohanad Ahmed
Mohanad Ahmed
TATareq Y. Al-Naffouri
Tareq Y. Al-Naffouri
High-accuracy range estimation is essential in modern applications and technologies. However, it is challenging to estimate the continuous-range of a moving target, especially under Doppler effects. This paper presents a novel signal design, which we name Differential Zadoff-Chu (DZC). Under Doppler effects, DZC sequences improve the performance of the maximum likelihood (ML)-based range estimation over its performance when using regular Zadoff-Chu (ZC) sequences. We propose a reduced-complexity ranging algorithm using DZC sequences and show that it outperforms the regular ZC ML-based range estimation. We evaluate the proposed system in a typical indoor environment using a low-cost ultrasound hardware. Under a low signal-to-noise ratio (-10 dB SNR), more than 90% of the range estimates have less than a 1.6 mm error, with a movement range from 0.2 m to 2.2 m and a maximum velocity of 0.5 m/s. For the same movement range, the system provides range estimates with a root-mean-square error (RMSE) of less than 0.76 mm in a high SNR scenario (10 dB), and an RMSE less than 0.85 mm in a low SNR scenario (-10 dB). For a larger movement range from 1.8 m to 4.2 m with a maximum velocity of 1.91 m/s, the proposed system provides range estimates with an RMSE less than 7.70 mm at 10 dB SNR.

5 February 2026 in arXiv
Verified
Preprint
Open access
PDF file
ASAon Safdar
Aon Safdar
MSMohamed Saadeldin
Mohamed Saadeldin
Vision Transformers (ViTs) have demonstrated strong performance across a range of computer vision tasks by modeling long-range spatial interactions via self-attention. However, channel-wise mixing in ViTs remains static, relying on fixed multilayer perceptrons (MLPs) that lack adaptability to input content. We introduce 'CAViT', a dual-attention architecture that replaces the static MLP with a dynamic, attention-based mechanism for feature interaction. Each Transformer block in CAViT performs spatial self-attention followed by channel-wise self-attention, allowing the model to dynamically recalibrate feature representations based on global image context. This unified and content-aware token mixing strategy enhances representational expressiveness without increasing depth or complexity. We validate CAViT across five benchmark datasets spanning both natural and medical domains, where it outperforms the standard ViT baseline by up to +3.6% in accuracy, while reducing parameter count and FLOPs by over 30%. Qualitative attention maps reveal sharper and semantically meaningful activation patterns, validating the effectiveness of our attention-driven token mixing.


31 October 2025 in arXiv
Verified
Preprint
Open access
PDF file
ASAon Safdar
Aon Safdar
MSMohamed Saadeldin
Mohamed Saadeldin
Vision Transformers (ViTs) have demonstrated strong potential in medical imaging; however, their high computational demands and tendency to overfit on small datasets limit their applicability in real-world clinical scenarios. In this paper, we present CoMViT, a compact and generalizable Vision Transformer architecture optimized for resource-constrained medical image analysis. CoMViT integrates a convolutional tokenizer, diagonal masking, dynamic temperature scaling, and pooling-based sequence aggregation to improve performance and generalization. Through systematic architectural optimization, CoMViT achieves robust performance across twelve MedMNIST datasets while maintaining a lightweight design with only ~4.5M parameters. It matches or outperforms deeper CNN and ViT variants, offering up to 5-20x parameter reduction without sacrificing accuracy. Qualitative Grad-CAM analyses show that CoMViT consistently attends to clinically relevant regions despite its compact size. These results highlight the potential of principled ViT redesign for developing efficient and interpretable models in low-resource medical imaging settings.