Keyvan Jaferzadeh

Dr. Keyvan Jaferzadeh

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MSMuhammad Saad Shaikh
Muhammad Saad Shaikh
KJKeyvan Jaferzadeh
Keyvan Jaferzadeh
BTBenny Thörnberg
Benny Thörnberg
JCJohan Casselgren
Johan Casselgren
In this paper, we present a hyper-spectral imaging system and practical calibration procedure using a low-cost calibration reference made of polytetrafluoroethylene. The imaging system includes a hyperspectral camera and an active source of illumination with a variable spectral distribution of intensity. The calibration reference is used to measure the relative reflectance of any material surface independent of the spectral distribution of light and camera sensitivity. Winter road conditions are taken as a test application, and several spectral images of snow, icy asphalt, dry asphalt, and wet asphalt were made at different exposure times using different illumination spectra. Graphs showing measured relative reflectance for different road conditions support the conclusion that measurements are independent of illumination. Principal component analysis of the acquired spectral data for road conditions shows well separated data clusters, demonstrating the system’s suitability for material classification.

1 January 2017
Verified
Journal Article
Closed access
MBManon Bardyn
Manon Bardyn
BRBenjamin Rappaz
Benjamin Rappaz
KJKeyvan Jaferzadeh
Keyvan Jaferzadeh
DCDavid Crettaz
David Crettaz
JTJean-Daniel Tissot
Jean-Daniel Tissot
MPMichel Prudent
Michel Prudent

31 July 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
KJKeyvan Jaferzadeh
Keyvan Jaferzadeh
SHSeung-Hyeon Hwang
Seung-Hyeon Hwang
IMInkyu Moon
Inkyu Moon
BJBahram Javidi
Bahram Javidi
Digital propagation of an off-axis hologram can provide the quantitative phase-contrast image if the exact distance between the sensor plane (such as CCD) and the reconstruction plane is correctly provided. In this paper, we present a deep-learning convolutional neural network with a regression layer as the top layer to estimate the best reconstruction distance. The experimental results obtained using microsphere beads and red blood cells show that the proposed method can accurately predict the propagation distance from a filtered hologram. The result is compared with the conventional automatic focus-evaluation function. Additionally, our approach can he utilized at the single-cell level, which is useful for cell-to-cell depth measurement and cell adherent studies. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

21 August 2020 in Optics Express
Verified
Journal Article
Closed access
IMInkyu Moon
Inkyu Moon
KJKeyvan Jaferzadeh
Keyvan Jaferzadeh
YKYouhyun Kim
Youhyun Kim
BJBahram Javidi
Bahram Javidi
This paper shows that deep learning can eliminate the superimposed twin-image noise in phase images of Gabor holographic setup. This is achieved by the conditional generative adversarial model (C-GAN), trained by input-output pairs of noisy phase images obtained from synthetic Gabor holography and the corresponding quantitative noise-free contrast-phase image obtained by the off-axis digital holography. To train the model, Gabor holograms are generated from digital off-axis holograms with spatial shifting of the real image and twin image in the frequency domain and then adding them with the DC term in the spatial domain. Finally, the digital propagation of the Gabor hologram with Fresnel approximation generates a super-imposed phase image for the C-GAN model input. Two models were trained: a human red blood cell model and an elliptical cancer cell model. Following the training, several quantitative analyses were conducted on the bio-chemical properties and similarity between actual noise-free phase images and the model output. Surprisingly, it is discovered that our model can recover other elliptical cell lines that were not observed during the training. Additionally, some misalignments can also be compensated with the trained model. Particularly, if the reconstruction distance is somewhat incorrect, this model can still retrieve in-focus images.

21 October 2015 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
KJKeyvan Jaferzadeh
Keyvan Jaferzadeh
IMInkyu Moon
Inkyu Moon
Quantitative phase information obtained by digital holographic microscopy (DHM) can provide new insight into the functions and morphology of single red blood cells (RBCs). Since the functionality of a RBC is related to its three-dimensional (3-D) shape, quantitative 3-D geometric changes induced by storage time can help hematologists realize its optimal functionality period. We quantitatively investigate RBC 3-D geometric changes in the storage lesion using DHM. Our experimental results show that the substantial geometric transformation of the biconcave-shaped RBCs to the spherocyte occurs due to RBC storage lesion. This transformation leads to progressive loss of cell surface area, surface-to-volume ratio, and functionality of RBCs. Furthermore, our quantitative analysis shows that there are significant correlations between chemical and morphological properties of RBCs.

10 September 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
KJKeyvan Jaferzadeh
Keyvan Jaferzadeh
IMInkyu Moon
Inkyu Moon
MBManon Bardyn
Manon Bardyn
MPMichel Prudent
Michel Prudent
JTJean-Daniel Tissot
Jean-Daniel Tissot
PMPierre Marquet
Pierre Marquet
We propose methods to quantitatively calculate the fluctuation rate of red blood cells with nanometric axial and millisecond temporal sensitivity at the single-cell level by using time-lapse holographic cell imaging. For this quantitative analysis, cell membrane fluctuations (CMFs) were measured for RBCs stored at different storage times. Measurements were taken over the whole membrane for both the ring and dimple sections separately. The measurements show that healthy RBCs that maintain their discocyte shape become stiffer with storage time. The correlation analysis demonstrates a significant negative correlation between CMFs and the sphericity coefficient, which characterizes the morphological type of erythrocyte. In addition, we show the correlation results between CMFs and other morphological properties such as projected surface area, surface area, mean corpuscular volume, and mean corpuscular hemoglobin.