Masayuki Sohgawa

Dr. Masayuki Sohgawa


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2012 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
MSMasayuki Sohgawa
Masayuki Sohgawa
DHDaiki Hirashima
Daiki Hirashima
YMYusuke Moriguchi
Yusuke Moriguchi
TUTatsuya Uematsu
Tatsuya Uematsu
WMWataru Mito
Wataru Mito
HNHaruo Noma
Haruo Noma

1 January 2009 in IEEJ Transactions on Sensors and Micromachines
Verified
Journal Article
Closed access
HOHiroyuki Onishi
Hiroyuki Onishi
MSMasayuki Sohgawa
Masayuki Sohgawa
HTHiroto Tachibana
Hiroto Tachibana
YHYu Ming Huang
Yu Ming Huang
TKTakeshi Kanashima
Takeshi Kanashima
HNHaruo Noma
Haruo Noma

1 January 2008 in IEEJ Transactions on Sensors and Micromachines
Verified
Journal Article
Closed access
YHYu Ming Huang
Yu Ming Huang
MSMasayuki Sohgawa
Masayuki Sohgawa
KYKaoru Yamashita
Kaoru Yamashita
TKTakeshi Kanashima
Takeshi Kanashima
MOMasanori Okuyama
Masanori Okuyama
HNHaruo Noma
Haruo Noma

1 January 2010 in IEEJ Transactions on Sensors and Micromachines
Verified
Journal Article
Closed access
HTHiroto Tachibana
Hiroto Tachibana
SKShiro Kamanaru
Shiro Kamanaru
TMTatsuya Mima
Tatsuya Mima
MSMasayuki Sohgawa
Masayuki Sohgawa
TKTakeshi Kanashima
Takeshi Kanashima
MHMasayoshi Higuchi
Masayoshi Higuchi

15 June 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
RARyoma Araki
Ryoma Araki
TATakashi Abe
Takashi Abe
HNHaruo Noma
Haruo Noma
MSMasayuki Sohgawa
Masayuki Sohgawa
In this paper, in order to perform delicate and advanced grip control like human, a proximity and tactile combination sensor using miniaturized microcantilevers one-fifth the size of previous one as the detection part was newly developed. Microcantilevers were arranged with higher spatial density than in previous works and an interdigitated array electrode to enhance light sensitivity was added. It is found that the interdigitated array electrode can detect light with 1.6 times higher sensitivity than that in previous works and the newly fabricated microcantilevers have enough sensitivity to applied normal and shear loads. Therefore, more accurate detection of proximity distance and spatial distribution of contact force become available for dexterous gripping control to prevent ‘overshooting’, ‘force control error’, and ‘slipping’.

1 June 2009
Verified
Conference Paper
Closed access
MSMasayuki Sohgawa
Masayuki Sohgawa
TMT. Mima
T. Mima
HOHiromitsu Onishi
Hiromitsu Onishi
TKT. Kanashima
T. Kanashima
MOM. Okuyama
M. Okuyama
HNH. Noma
H. Noma
Tactile array sensor of the micro-cantilevers embedded in the elastomer has been fabricated to detect normal and 2-axes shear stresses. It is demonstrated that tactile array sensor with 3 times 3 detective elements can be fabricated with excellent yield. The sensor element is sensitive to both normal and shear stresses applied on entire sensor surface. Moreover, it has good directional characteristics so that it is shown that magnitude and direction of shear stress can be obtained by difference of output voltages of adjacent sensor cantilevers. The sensor output has good reproducibility for multiple measurement. The output from sensor element drastically changes with shifting applying position of force. It is considered that we can obtain pressed position from distribution of output from sensor element array.