Seong-Joon Moon

Mr. Seong-Joon Moon

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2023 in Fluids
Verified
Journal Article
Open access
PDF file
Soo Jin JeongSoo Jin Jeong
Soo Jin Jeong
Sang-Jin LeeSang-Jin Lee
Sang-Jin Lee
SMSeong-Joon Moon
Seong-Joon Moon
Accurate evaluation of thermo-fluid dynamic characteristics in tanks is critically important for designing liquid hydrogen tanks for small-scale hydrogen liquefiers to minimize heat leakage into the liquid and ullage. Due to the high costs, most future liquid hydrogen storage tank designs will have to rely on predictive computational models for minimizing pressurization and heat leakage. Therefore, in this study, to improve the storage efficiency of a small-scale hydrogen liquefier, a three-dimensional CFD model that can predict the boil-off rate and the thermo-fluid characteristics due to heat penetration has been developed. The prediction performance and accuracy of the CFD model was validated based on comparisons between its results and previous experimental data, and a good agreement was obtained. To evaluate the insulation performance of polyurethane foam with three different insulation thicknesses, the pressure changes and thermo-fluid characteristics in a partially liquid hydrogen tank, subject to fixed ambient temperature and wind velocity, were investigated numerically. It was confirmed that the numerical simulation results well describe not only the temporal variations in the thermal gradient due to coupling between the buoyance and convection, but also the buoyancy-driven turbulent flow characteristics inside liquid hydrogen storage tanks with different insulation thicknesses. In the future, the numerical model developed in this study will be used for optimizing the insulation systems of storage tanks for small-scale hydrogen liquefiers, which is a cost-effective and highly efficient approach.

9 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Soo Jin JeongSoo Jin Jeong
Soo Jin Jeong
Sang-Jin LeeSang-Jin Lee
Sang-Jin Lee
SMSeong-Joon Moon
Seong-Joon Moon
Accurate evaluation of thermo-fluid dynamic characteristics in tank are critically important for designing liquid hydrogen tank of small-scale hydrogen liquefier to minimize heat in-leak into the liquid and ullage. Due to the huge cost, most future liquid hydrogen storage tank designs will have to rely on predictive computational models for storage tank pressurization and heat-leak minimization. Thus, reliable on predictive numerical models to aid design process of tank design have been required. Therefore, in this study, in order to improve the storage efficiency of the small-scale hydrogen liquefier, a three-dimensional CFD model that can predict the boil-off rate and the thermo-fluid characteristics due to heat penetration has been developed. The prediction performance and accuracy of the CFD model is validated on the basis of the comparisons between its results and previous experimental data and a good agreement is obtained. To evaluate insulation performance of polyurethane foam according to thickness, the pressure change and thermo-fluid characteristics in a partially liquid hydrogen tank, subject to fixed ambient temperature and wind velocity, has been investigated numerically. Three different insulation thickness were considered to investigate not only interfacial characteristics between liquid and ullage but thermo-fluid dynamics in hydrogen storage tank for various heat-leak situation. The results indicate that as the insulation thickness becomes thinner and more heat penetration exists, natural convection by buoyancy develops stronger, so strong vortices are created near the interfacial zone by upward flow driven by buoyancy. In particular, as the amount of heat in-leak increased, wider and stronger heat accumulation was found in the top dished head area of the ullage area. In addition, it was confirmed that the CFD model developed in this study could well describe the phenomenon in which the temperature of the tank wall and the insulation mat increased at a faster rate due to faster heat transfer from the vapor and interface. In the future, the numerical model developed in this study will be used for optimizing insulation system of storage tank for small-scale hydrogen which is cost-effective and highly efficient.

23 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
Soo Jin JeongSoo Jin Jeong
Soo Jin Jeong
SSSeokpan Seo
Seokpan Seo
SMSeong-Joon Moon
Seong-Joon Moon
This study develops and validates a three-dimensional CFD model for a 12 L large-bore active-type pre-chamber spark-ignition (PCSI) engine fueled by natural gas. The model incorporates an advanced Extended Coherent Flamelet Model (ECFM-3Z) with a tuned stretch factor to capture complex turbulence–flame interactions, flame propagation, and pollutant formation under ultra-lean conditions. By systematically varying pre-chamber geometries—specifically the orifice diameter, cone angle, diverging tapered nozzle, and volume—the simulations assess their effects on combustion dynamics, heat release rates, turbulent jet penetration, and emissions (NOx and CO). Model predictions of in-cylinder and pre-chamber pressure profiles, combustion phasing, and emission trends are validated against experimental data. The results demonstrate that optimizing pre-chamber and orifice configurations enhances turbulent mixing, accelerates flame development, and reduces local high-temperature zones, thereby suppressing NOx and CO formation. Although some discrepancies in NOx predictions persist due to limitations in current turbulence–chemistry models, the findings offer valuable insights for the design of high-efficiency, low-emission PCSI engines.

11 March 2024 in Actuators
Verified
Journal Article
Open access
PDF file
Soo Jin JeongSoo Jin Jeong
Soo Jin Jeong
JKJi-Hoon Kang
Ji-Hoon Kang
SMSeong-Joon Moon
Seong-Joon Moon
GLGum-Su Lee
Gum-Su Lee
In order to maintain the performance of a fuel cell vehicle, it is essential to maintain a constant temperature of the stack. Therefore, it is very important to distribute the optimal coolant flow rate to each major component under very diverse and rapidly changing dynamic operating conditions. The part responsible for this is a five-way electric coolant valve. Therefore, this study aims to investigate transient dynamic flow characteristics of the fluid flow through a five-way electric coolant valve (PCCV: Penta-Control Coolant Valve). To achieve this goal, this paper attempts a three-dimensional dynamic simulation of the fluid flow through the valve using a commercial CFD solver with moving mesh technique to consider flow inertia and dynamic flow in the opening and closing stages of the ball valve rotating motion. The dynamic flow characteristics and the thermal mixing inside the PCCV ball valve during the opening and closing stages are analyzed. It was found that the discrepancies between dynamic and steady-state simulations are remarkable when fluxes with different levels of enthalpy and momentum flow into the PCCV, leading to strong flow interference and flow inertia, while the discrepancies are relatively small at low rotation speed and weak flow interference. Subsequently, the effect of the dynamic flow characteristics of the valve on the dynamic thermal mixing characteristics at two different ball valve rotation speeds and rotation directions are investigated. It was found that the dynamic flow and thermal mixing characteristics inside the PCCV are greatly affected by the rotation speed, rotation direction, and degree of flow interference between fluxes. It also helps design better coolant control strategies and improves the FCEV thermal management system.

1 September 2017 in Transaction of the Korean Society of Automotive Engineers
Verified
Journal Article
Closed access
CNChungwoo Nam
Chungwoo Nam
HLHokil Lee
Hokil Lee
SMSeong-Joon Moon
Seong-Joon Moon
JKJaekwang Kim
Jaekwang Kim
GKGuho Kim
Guho Kim
KLKangyoon Lee
Kangyoon Lee

2 December 2024 in Actuators
Verified
Journal Article
Open access
PDF file
Soo Jin JeongSoo Jin Jeong
Soo Jin Jeong
SMSeong-Joon Moon
Seong-Joon Moon
This study examines the dynamic fluid behavior of a PWM-controlled Solenoid-Operated Gas Admission Valve (SOGAV) for large-bore CNG engines using 3D Computational Fluid Dynamics (CFD) simulations with dynamic mesh techniques. The research focuses on the influence of orifice geometry variations in the multi-hole restrictor and pressure differentials between the inlet and outlet on flow stability, turbulence, and valve performance. Results demonstrate that multi-hole restrictors with different-sized orifices improve flow uniformity and reduce turbulence, thereby mitigating flow resistance. Transient simulations further reveal standing wave formation and pressure wave interference, emphasizing that steady-state models cannot capture critical transient phenomena, such as accelerated and decelerated jet-like flows and flow separation. These findings provide key insights into SOGAV optimization, contributing to enhanced fuel efficiency and engine responsiveness, meeting the performance requirements of modern gas engines.