Anja Viestenz

Dr. Anja Viestenz

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2017 in Advances in Therapy
Verified
Journal Article
Closed access
PDF file
MFMiltiadis Fiorentzis
Miltiadis Fiorentzis
EMEmanuela Morinello
Emanuela Morinello
AVAnja Viestenz
Anja Viestenz
HZHanna Zuche
Hanna Zuche
Berthold SeitzBerthold Seitz
Berthold Seitz
AVArne Viestenz
Arne Viestenz

14 June 2017 in Clinical Anatomy
Verified
Journal Article
Closed access
PDF file
AVArne Viestenz
Arne Viestenz
Berthold SeitzBerthold Seitz
Berthold Seitz
EDEva Deland
Eva Deland
MFMiltiadis Fiorentzis
Miltiadis Fiorentzis
LLLorenz Latta
Lorenz Latta
BKBarbara Käsmann-Kellner
Barbara Käsmann-Kellner

24 July 2017 in Clinical Anatomy
Verified
Journal Article
Closed access
PDF file
MFMiltiadis Fiorentzis
Miltiadis Fiorentzis
AVAnja Viestenz
Anja Viestenz
JHJens Heichel
Jens Heichel
Berthold SeitzBerthold Seitz
Berthold Seitz
THThomas Hammer
Thomas Hammer
AVArne Viestenz
Arne Viestenz

30 September 2017 in Clinical Anatomy
Verified
Journal Article
Closed access
PDF file
AVAnja Viestenz
Anja Viestenz
Berthold SeitzBerthold Seitz
Berthold Seitz
HSHans‐Gert Struck
Hans‐Gert Struck
AVArne Viestenz
Arne Viestenz

1 January 2002 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
ALAchim Langenbucher
Achim Langenbucher
AVAnja Viestenz
Anja Viestenz
Berthold SeitzBerthold Seitz
Berthold Seitz
PURPOSE: To demonstrate a mathematical method for approximation of discrete corneal topography height data with a biconic model surface for better appreciation of the optical performance of the graft after penetrating keratoplasty. METHODS: In this retrospective study we included 50 eyes of 50 patients (30 keratoconus; 20 Fuchs' dystrophy) undergoing nonmechanical excimer laser penetrating keratoplasty. Conventional keratometry, corneal topography (TMS-I), subjective refraction, and best spectacle-corrected visual acuity (BSCVA) were assessed preoperativeIy, 3 and 6 months postoperatively, and before/after suture removal. A biconic model surface was fitted to the topographic raw data (8.0-mm region of interest) minimizing the root mean square error and a set of parameters (meridional power, axis, conic constant, and approximation error) was determined. The refractive cylinder was correlated with keratometric power readings, the Simulated Keratometry (SimK) of the topography system, and the respective parameters of the model surface. RESULTS: Keratometric/SimK astigmatism increased from preoperatively (3.40/4.30 D) to 3 months (4.30/4.80 D) and decreased to 3.40/3.90 D after suture removal. Refractive cylinder/cylinder of the biconic increased slightly from 2.10/2.60 D preoperatively to 3.20/3.30 D after suture removal. The topographic cylinder SimK yielded the highest and the refractive cylinder the lowest values at each follow-up examination. Central keratometric power readings were stable before suture removal and decreased (about 1 D) due to suture removal. The conic constants in both meridional cross-sections changed from a prolate to a spherical shape in the early time course after penetrating keratoplasty and reconverted to a prolate shape after suture removal. Regarding cylinder axis, there was a significant correlation of the model surface with the refractive cylinder at all examinations (P<05) but only a mild correlation of the keratometric and SimK cylinder axis to the refractive cylinder axis at some examination stages. CONCLUSION: Approximation of corneal topography height data with a biconic model surface renders reconstruction of clinically relevant corneal topography parameters including corneal asphericity with marked data compression. The correlation of amount/axis of refractive cylinder was best represented with the model surface parameters. [J Refract Surg 2002;18:63-71]

22 June 2007 in Der Ophthalmologe
Verified
Journal Article
Closed access
PDF file
AVArne Viestenz
Arne Viestenz
SWSibi Walter
Sibi Walter
AVAnja Viestenz
Anja Viestenz
WBW. Behrens-Baumann
W. Behrens-Baumann
ALAchim Langenbucher
Achim Langenbucher