This study aims to analyze the thermal comfort level of students in secondary schools in the tropical city of Makassar. The analysis is carried out based on data surveyed from eight selected high schools. The study involved 1594 students in 48 classrooms. The recorded data includes personal data and measured environmental parameters. At the same time, students were asked to fill out questionnaires related to their thermal comfort levels. The surveyed classrooms showed high air temperatures. The air temperatures ranged from 28.2 °C in the morning to 33.6 °C in the midday. The radiant temperatures were similar to the air temperature, which indicated that the airflow speed was low. The only parameter that could meet the Indonesian national standard was relative humidity. However, many students still feel comfortable (−1 to +1) based on TSV (thermal sensation vote) and TCV (thermal comfort vote). Even though about 80% of respondents accepted this hot temperature, most of them preferred to have a decrease in the air temperature. Regarding the PMV (predicted mean vote), only about 23% respondents were predicted to feel slightly warm (+1). The regression analyses show that the neutral temperatures were 29.0 °C and 28.5 °C for TSV and TCV, respectively.
Purpose: The purpose of this paper is to analyse thermal comfort and the thermal environment in naturally ventilated classrooms. Specifically, the aims of the study were to identify the thermal environment and thermal comfort of respondents in naturally ventilated university classrooms and compare them with the ASHRAE and Indonesian National Standard (SNI); to check on whether the predicted mean vote (PMV) model is applicable or not for predicting the thermal comfort of occupants in naturally ventilated university classrooms; and to analyse the neutral temperature of occupants in the naturally ventilated university classrooms. Design/methodology/approach: The study was carried out at the new campus of Faculty of Engineering, Hasanuddin University, Gowa campus. A number of field surveys, which measured thermal environments, namely, air temperature, mean radiant temperature (MRT), relative humidity, and air velocity, were carried out. The personal activity and clothing properties were also recorded. At the same time, respondents were asked to fill a questionnaire to obtain their thermal sensation votes (TSV) and thermal comfort votes (TCV), thermal preference, and thermal acceptance. A total of 118 respondents participated in the study. Before the survey was conducted, a brief explanation was provided to the participants to ensure that they understood the study objectives and also how to fill in the questionnaires. Findings: The results indicated that the surveyed classrooms had higher thermal environments than those specified in the well-known ASHRAE standard and Indonesian National Standard (SNI). However, this condition did not make respondents feel uncomfortable because a large proportion of respondents voted within the comfort zone (+1, 0, and −1). The predictive mean vote using the PMV model was higher than the respondents’ votes either by TSV or by TCV. There was a huge difference between neutral temperature using operative temperature (To) and air temperature (Ta). This difference may have been because of the small value of MRT recorded in the measured classrooms. Originality/value: The research shows that the use of the PMV model in predicting thermal comfort in the tropic region might be misleading. This is because PMV mostly overestimates the TSV and TCV of the respondents. People in the tropic region are more tolerant to a higher temperature. On the basis of this finding, there is a need to develop a new thermal comfort model for university classrooms that is particularly optimal for this tropical area.
A preliminary analysis of daylight data in Hong Kong was carried out. This analysis classified daylight data into three sky conditions—clear, intermediate and overcast—using two methods, that is, sunshine duration and cloud ratio methods. It was carried out based on data measured at the daylight station located in the University of Hong Kong main campus, which was collected during October 2006 to September 2007. The probabilities of the occurrence of the three sky conditions were 3.78% (clear), 67.10% (intermediate), 29.11% (overcast) and 4.78% (clear), 65.17% (intermediate), 30.34% (overcast) using sunshine duration and cloud ratio methods, respectively. The statistical analysis t-test showed that the two sets of probabilities were the same. It was also found that a global and diffuse horizontal illuminance of more than 10klux was available 85% of the time, which indicated that daylight illuminance was sufficiently available in the unobstructed sky of Hong Kong.
12 December 2017 in International Journal of Sustainable Energy
This study aims to design energy efficient and thermally comfortable air-conditioning system in university classrooms. The research has been conducted in two steps. The first step was a survey of students’ thermal comfort under air-conditioning classrooms, which collecting 175 questionnaires from 92 students. The second step was the calculation of cooling energy consumption using the EnergyPlus software. With the air temperature ranged from 23.0 to 27.0°C about 53% of respondents felt uncomfortable (cold or cool). The neutral temperature of students was found to be 27.0°C, which is higher than the classrooms’ temperature. The energy simulation results show that the most significant factors affecting energy use is the temperature setting. Therefore, there is a possibility to reduce the cooling energy while improving the thermal comfort of students. To this end, it is recommended to raise the air temperature setting from 25.0°C to a minimum of 26.0°C.
16 March 2018 in IOP Conference Series: Earth and Environmental Science
In The existence of chicken fur is a waste of chicken slaughterhouse Which is produced daily and still not widely used. Likewise cartons everywhere we can see its being because its function is so great in all human activities In the fulfillment of the need for storage and packaging of goods for human purposes such as electronic goods, commodity, Because it has a relatively large thickness of paper. Several studies have proven that Quill and cardboard can be used for acoustic materials. This study aims to identify the potential of chicken fur and cardboard to be created as panel materials Which acts as an acoustic panel. . This study uses an experimental method by combining two materials, Including waste Quill and carton waste by performing several stages in the formation of panels, Such as the selection of chicken fur material and cardboard cleaning process, drying process, enumeration process, panel modeling process. The result of this research is acoustic panel model with size 20x20cm2 with thickness 9 and 18 mm, The study also produced a Ø9,8 cm diameter-shaped panel model with 1.5cm, 2.5cm, and 5cm thickness for use in testing absorption coefficients using impedance tubes.