Birgit Nierula

Dr. Birgit Nierula

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in The Journal of Pain
Verified
Journal Article
Closed access
BNBirgit Nierula
Birgit Nierula
MMMatteo Martini
Matteo Martini
MMMarta Matamala-Gomez
Marta Matamala-Gomez
MSMel Slater
Mel Slater
MSMaria V. Sanchez-Vives
Maria V. Sanchez-Vives

3 December 2019 in The Journal of Physiology
Verified
Journal Article
Closed access
PDF file
BNBirgit Nierula
Birgit Nierula
BSBernhard Spanlang
Bernhard Spanlang
MMMatteo Martini
Matteo Martini
MBMireia Borrell
Mireia Borrell
VNVadim V. Nikulin
Vadim V. Nikulin
MSMaria V. Sanchez-Vives
Maria V. Sanchez-Vives

21 January 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MMMarta Matamala-Gomez
Marta Matamala-Gomez
BNBirgit Nierula
Birgit Nierula
TDTony Donegan
Tony Donegan
MSMel Slater
Mel Slater
MSMaria V. Sanchez-Vives
Maria V. Sanchez-Vives
Changes in body representation may affect pain perception. The effect of a distorted body image, such as the telescoping effect in amputee patients, on pain perception, is unclear. This study aimed to investigate whether distorting an embodied virtual arm in virtual reality (simulating the telescoping effect in amputees) modulated pain perception and anticipatory responses to pain in healthy participants. Twenty-seven right-handed participants were immersed in virtual reality and the virtual arm was shown with three different levels of distortion with a virtual threatening stimulus either approaching or contacting the virtual hand. We evaluated pain/discomfort ratings, ownership, and skin conductance responses (SCRs) after each condition. Viewing a distorted virtual arm enhances the SCR to a threatening event with respect to viewing a normal control arm, but when viewing a reddened-distorted virtual arm, SCR was comparatively reduced in response to the threat. There was a positive relationship between the level of ownership over the distorted and reddened-distorted virtual arms with the level of pain/discomfort, but not in the normal control arm. Contact with the threatening stimulus significantly enhances SCR and pain/discomfort, while reduced SCR and pain/discomfort were seen in the simulated-contact condition. These results provide further evidence of a bi-directional link between body image and pain perception.

1 August 2013 in NeuroImage
Verified
Journal Article
Closed access
BNBirgit Nierula
Birgit Nierula
FHFriederike U. Hohlefeld
Friederike U. Hohlefeld
GCGabriel Curio
Gabriel Curio
VNVadim V. Nikulin
Vadim V. Nikulin

5 December 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
BNBirgit Nierula
Birgit Nierula
TSTilman Stephani
Tilman Stephani
EBEmma Bailey
Emma Bailey
MKMerve Kaptan
Merve Kaptan
LPLisa-Marie Pohle
Lisa-Marie Pohle
FEFalk Eippert
Falk Eippert
The spinal cord is of fundamental importance for integrative processing in brain-body communication, yet routine non-invasive recordings in humans are hindered by vast methodological challenges. Here we overcome these challenges by developing an easy-to-use electrophysiological approach based on high-density multi-channel spinal recordings combined with multivariate spatial-filtering analyses. These advances enable a spatiotemporal characterization of spinal cord responses and demonstrate a sensitivity that permits assessing even single-trial responses. To furthermore enable the study of integrative processing along the neural processing hierarchy in somatosensation, we expand this approach by simultaneous peripheral, spinal and cortical recordings and provide direct evidence that bottom-up integrative processing occurs already within the spinal cord and thus after the first synaptic relay in the central nervous system. Finally, we demonstrate the versatility of this approach by providing non-invasive recordings of nociceptive spinal cord responses during heat-pain stimulation. Beyond establishing a new window on human spinal cord function at millisecond timescale, this work provides the foundation to study brain-body communication in its entirety in health and disease.

10 September 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
EBEmma Bailey
Emma Bailey
BNBirgit Nierula
Birgit Nierula
TSTilman Stephani
Tilman Stephani
BMBurkhard Maess
Burkhard Maess
VNVadim Nikulin
Vadim Nikulin
FEFalk Eippert
Falk Eippert
The spinal cord is a vital component of the central nervous system for the processing of sensorimotor information transmitted between the body and the brain. Electrospinography (ESG) is the most accessible non-invasive technique for recording spinal signals in humans, but the vast and detrimental impact of physiological noise (mostly of cardiac nature) has prevented widespread adoption. Here, we aim to address this issue by examining various denoising algorithms for cardiac artefact reduction – including principal component analysis-based techniques (PCA), independent component analysis-based approaches (ICA) and signal space projection (SSP). We observed that in situations where large numbers of spinal electrodes are used, SSP offers the best results in terms of balancing the removal of harmful noise and preserving neural information of interest. In cases where only a small number of electrodes are available, an approach based on PCA is deemed helpful. Approaches based on ICA were found to be unsuitable for cardiac artefact removal in ESG, due to a suboptimal balance of artefact removal and signal preservation. Finally, we also approached this issue from a signal-enhancement perspective and observed that in cases where extensive electrode arrays are used in the context of task-based designs, a spatial filtering technique based on canonical correlation analysis (CCA) reveals clear evoked spinal potentials even with single-trial resolution. Taken together, there are several appropriate algorithms for physiological noise removal in ESG, rendering this an accessible and easy-to-use technique for non-invasive assessments of human spinal cord function.