Objective To assess the role of nasal continuous positive airway pressure (CPAP) initiated at birth for prevention of death and bronchopulmonary dysplasia in very preterm infants. Design Systematic review. Data sources PubMed, Embase, the Cochrane Central Register of Controlled Trials, and online Pediatric Academic Society abstracts from the year of inception to June 2013. Eligibility criteria for selecting studies Randomised controlled trials evaluating the effect of nasal CPAP compared with intubation in preterm infants born at less than 32 weeks’ gestation and presenting the outcomes of either death or bronchopulmonary dysplasia, or both (defined as the need for oxygen support or mechanical ventilation at 36 weeks corrected gestation), during hospital stay. Results Four randomised controlled trials (2782 participants) met the inclusion criteria, with 1296 infants in the nasal CPAP group and 1486 in the intubation group. All the trials reported bronchopulmonary dysplasia independently at 36 weeks corrected gestation, with borderline significance in favour of the nasal CPAP group (relative risk 0.91, 95% confidence interval 0.82 to 1.01, risk difference −0.03, 95% confidence interval −0.07 to 0.01). No difference in death was observed (relative risk 0.88, 0.68 to 1.14, risk difference −0.02, −0.04 to 0.01, respectively). Pooled analysis showed a significant benefit for the combined outcome of death or bronchopulmonary dysplasia, or both, at 36 weeks corrected gestation for babies treated with nasal CPAP (relative risk 0.91, 0.84 to 0.99, risk difference −0.04, -0.07 to 0.00), number needed to treat of 25). Conclusion One additional infant could survive to 36 weeks without bronchopulmonary dysplasia for every 25 babies treated with nasal CPAP in the delivery room rather than being intubated.
BACKGROUND AND OBJECTIVE: Transcutaneous bilirubin (TcB) devices are widely used for the estimation of serum bilirubin levels in term and near-term infants. Our objective was to review the diagnostic accuracy of TcB devices in preterm infants. METHODS: Medline, Embase, Cochrane library, Cumulative Index to Nursing and Allied Health Literature, and Scopus were searched (from database inception date until December 2012). Additional citations were identified by using the bibliographies of selected articles and from conference proceedings. The studies were included if they compared TcB with total serum bilirubin in preterm infants before phototherapy and presented data as correlation coefficients or as Bland-Altman difference plots. Data were extracted by 1 reviewer and checked for accuracy by the second reviewer. An assessment tool (quality assessment of diagnostic accuracy studies) was used for risk of bias assessments. RESULTS: Twenty-two studies met the inclusion criteria; 21 studies reported results as correlation coefficients, with pooled estimates of r = 0.83 for each site of measurement. Pooled estimates in infants <32 weeks’ gestation were similar to the overall preterm population (r = 0.89 [95% confidence interval: 0.82–0.93]). For the 2 commonly used TcB devices (ie, JM103 and BiliCheck), the results were comparable at the forehead site, although the JM103 device exhibited better correlation at the sternum. Analysis of the Bland-Altman plots (13 studies) revealed negligible bias in measurement at the forehead or sternum site by using either the JM-103 or BiliCheck device; however, the JM-103 device exhibited better precision than the BiliCheck (SD for TcB – total serum bilirubin differences: 24.3 and 31.98 µmol/L, respectively). CONCLUSIONS: The TcB devices reliably estimated bilirubin levels in preterm infants and could be used in clinical practice to reduce blood sampling.
30 December 2014 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Context: Sustained inflation (SI) has been advocated as an alternative to intermittent positive pressure ventilation (IPPV) during the resuscitation of neonates at birth, to facilitate the early development of an effective functional residual capacity, reduce atelectotrauma and improve oxygenation after the birth of preterm infants. Objective: The primary aim was to review the available literature on the use of SI compared with IPPV at birth in preterm infants for major neonatal outcomes, including bronchopulmonary dysplasia (BPD) and death. Data source: MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials, until 6 October 2014. Study selection: Randomised clinical trials comparing the effects of SI with IPPV at birth in preterm infants for neonatal outcomes. Data extraction and synthesis: Descriptive and quantitative information was extracted; data were pooled using a random effects model. Heterogeneity was assessed using the Q statistic and I2. Results: Pooled analysis showed significant reduction in the need for mechanical ventilation within 72 h after birth (relative risk (RR) 0.87 (0.77 to 0.97), absolute risk reduction (ARR) −0.10 (−0.17 to −0.03), number needed to treat 10) in preterm infants treated with an initial SI compared with IPPV. However, significantly more infants treated with SI received treatment for patent ductus arteriosus (RR 1.27 (1.05 to 1.54), ARR 0.10 (0.03 to 0.16), number needed to harm 10). There were no differences in BPD, death at the latest follow-up and the combined outcome of death or BPD among survivors between the groups. Conclusions: Compared with IPPV, preterm infants initially treated with SI at birth required less mechanical ventilation with no improvement in the rate of BPD and/or death. The use of SI should be restricted to randomised trials until future studies demonstrate the efficacy and safety of this lung aeration manoeuvre.
We retrospectively investigated incidence, morbidity, and mortality of neonatal necrotizing enterocolitis in China, with special emphasis on determining the predictors of necrotizing enterocolitis associated mortality. We identified neonates as having necrotizing enterocolitis if they met the accepted diagnostic criterion. Data pertaining to antenatal period, labor and birth, and the postnatal course of illness were collected. Multivariate analysis and logistic regression were used to analyze the risk factors. There were 1167 cases of necrotizing enterocolitis identified from the 95 participating NICUs in mainland China in 2011, with the incidence of 2.50% and 4.53% in LBW (birth weight <2500 g) and VLBW (birth weight <1500 g) infants, respectively. Stage 1, 2 and 3 diseases were noted in 51.1%, 30.3% and 18.6% of cases respectively. The mortality from stage 2 and 3 necrotizing enterocolitis in this cohort was 41.7%. In VLBW infants, the important risk factors for mortality were small for gestation age (OR: 5.02, 95% CI 1.73-14.6; P = 0.003) and stage 3 NEC (OR: 8.09, 95% CI 2.80-23.3, P < 0.001). In moderate LBW infants (birth weight 1500-2499 g), the risk factors identified for mortality were sepsis during hospitalization (OR: 2.59, 95% CI 1.57-4.28, P < 0.001) and stage 3 NEC (OR: 5.37, 95% CI 3.24-8.90; P < 0.001). Necrotizing enterocolitis remains an important cause of morbidity and mortality in prematurely born neonates in Chinese neonatal units. Awareness of the associated risk factors and appropriate interventions may improve the outcome of necrotizing enterocolitis in different birth weight subgroup.
Background: Transcutaneous bilirubin (TcB) devices are commonly used for screening of hyperbilirubinemia in term and near-term infants not exposed to phototherapy. However, the accuracy of TcB devices in infants exposed to phototherapy is unclear. Objectives: To conduct a systematic review of studies comparing TcB devices with total serum bilirubin (TSB) in infants receiving phototherapy or in the postphototherapy phase. Methods: MEDLINE, EMBASE, Cochrane Library, CINAHL and Scopus databases (from inception to May 8, 2014) were searched. Additional citations were identified from the bibliography of selected articles and from the abstracts of conference proceedings. The studies were included if they compared TcB results with TSB in term and near-term infants during phototherapy or after discontinuation of phototherapy. Two reviewers independently assessed studies for inclusion, and discrepancies were resolved with consensus. Risk of bias was assessed using the QUADAS-2 tool. Results: Fourteen studies were identified. The pooled estimates of correlation coefficients (r) during phototherapy were: covered sites 0.71 (95% CI 0.64-0.77, 11 studies), uncovered sites 0.65 (95% CI 0.55-0.74), 8 studies), forehead 0.70 (95% CI 0.64-0.75, 12 studies) and sternum 0.64 (95% CI 0.43-0.77, 5 studies). Two studies also provided results as Bland-Altman difference plots (mean TcB-TSB differences -29.2 and 30 µmol/l, respectively). The correlation coefficient improved marginally in the postphototherapy phase (r = 0.72, 95% CI 0.64-0.78, 4 studies). Conclusion: We found a moderate correlation between TcB and TSB during phototherapy with a marginal improvement in the postphototherapy phase. Further research is needed before the use of TcB devices can be recommended for these settings.
Background: An accurate assessment of the adequacy of prenatal care utilization is critical to inform the relationship between prenatal care and pregnancy outcomes. This systematic review critically appraises the evidence on measurement properties of prenatal care utilization indices and provides recommendations about which index is the most useful for this purpose. Methods: MEDLINE, EMBASE, CINAHL, and Web of Science were systematically searched from database inception to October 2018 using keywords related to indices of prenatal care utilization. No language restrictions were imposed. Studies were included if they evaluated the reliability, validity, or responsiveness of at least one index of adequacy of prenatal care utilization. We used the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. We conducted an evidence synthesis using predefined criteria to appraise the measurement properties of the indices. Results: From 2664 studies initially screened, 13 unique studies evaluated the measurement properties of at least one index of prenatal care utilization. Most of the indices of adequacy of prenatal care currently used in research and clinical practice have been evaluated for at least some form of reliability and/or validity. Evidence about the responsiveness to change of these indices is absent from these evaluations. The Adequacy Perinatal Care Utilization Index (APNCUI) and the Kessner Index are supported by moderate evidence regarding their reliability, predictive and concurrent validity. Conclusion: The scientific literature has not comprehensively reported the measurement properties of commonly used indices of prenatal care utilization, and there is insufficient research to inform the choice of the best index. Lack of strong evidence about which index is the best to measure prenatal care utilization has important implications for tracking health care utilization and for formulating prenatal care recommendations.