Liangbo Linus Shen

Dr. Liangbo Linus Shen


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
OCO. M. Carrasco-Zevallos
O. M. Carrasco-Zevallos
BKB. Keller
B. Keller
CVC. Viehland
C. Viehland
LSLiangbo Linus Shen
Liangbo Linus Shen
GWG. Waterman
G. Waterman
JIJ. A. Izatt
J. A. Izatt
Minimally-invasive microsurgery has resulted in improved outcomes for patients. However, operating through a microscope limits depth perception and fixes the visual perspective, which result in a steep learning curve to achieve microsurgical proficiency. We introduce a surgical imaging system employing four-dimensional (live volumetric imaging through time) microscope-integrated optical coherence tomography (4D MIOCT) capable of imaging at up to 10 volumes per second to visualize human microsurgery. A custom stereoscopic heads-up display provides real-time interactive volumetric feedback to the surgeon. We report that 4D MIOCT enhanced suturing accuracy and control of instrument positioning in mock surgical trials involving 17 ophthalmic surgeons. Additionally, 4D MIOCT imaging was performed in 48 human eye surgeries and was demonstrated to successfully visualize the pathology of interest in concordance with preoperative diagnosis in 93% of retinal surgeries and the surgical site of interest in 100% of anterior segment surgeries. In vivo 4D MIOCT imaging revealed sub-surface pathologic structures and instrument-induced lesions that were invisible through the operating microscope during standard surgical maneuvers. In select cases, 4D MIOCT guidance was necessary to resolve such lesions and prevent post-operative complications. Our novel surgical visualization platform achieves surgeon-interactive 4D visualization of live surgery which could expand the surgeon’s capabilities.

12 April 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
CVChristian Viehland
Christian Viehland
BKBrenton Keller
Brenton Keller
OCOscar M. Carrasco-Zevallos
Oscar M. Carrasco-Zevallos
DNDerek Nankivil
Derek Nankivil
LSLiangbo Linus Shen
Liangbo Linus Shen
JIJoseph A. Izatt
Joseph A. Izatt
Current-generation software for rendering volumetric OCT data sets based on ray casting results in volume visualizations with indistinct tissue features and sub-optimal depth perception. Recent developments in hand-held and microscope-integrated intrasurgical OCT designed for real-time volumetric imaging motivate development of rendering algorithms which are both visually appealing and fast enough to support real time rendering, potentially from multiple viewpoints for stereoscopic visualization. We report on an enhanced, real time, integrated volumetric rendering pipeline which incorporates high performance volumetric median and Gaussian filtering, boundary and feature enhancement, depth encoding, and lighting into a ray casting volume rendering model. We demonstrate this improved model implemented on graphics processing unit (GPU) hardware for real-time volumetric rendering of OCT data during tissue phantom and live human surgical imaging. We show that this rendering produces enhanced 3D visualizations of pathology and intraoperative maneuvers compared to standard ray casting.

1 July 2016 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
OCOscar M. Carrasco-Zevallos
Oscar M. Carrasco-Zevallos
BKBrenton Keller
Brenton Keller
CVChristian Viehland
Christian Viehland
LSLiangbo Linus Shen
Liangbo Linus Shen
MSMichael I. Seider
Michael I. Seider
CTCynthia A. Toth
Cynthia A. Toth
Magnification of the surgical field using the operating microscope facilitated profound innovations in retinal surgery in the 1970s, such as pars plana vitrectomy. Although surgical instrumentation and illumination techniques are continually developing, the operating microscope for vitreoretinal procedures has remained essentially unchanged and currently limits the surgeon's depth perception and assessment of subtle microanatomy. Optical coherence tomography (OCT) has revolutionized clinical management of retinal pathology, and its introduction into the operating suite may have a similar impact on surgical visualization and treatment. In this article, we review the evolution of OCT for retinal surgery, from perioperative analysis to live volumetric (four-dimensional, 4D) image-guided surgery. We begin by briefly addressing the benefits and limitations of the operating microscope, the progression of OCT technology, and OCT applications in clinical/perioperative retinal imaging. Next, we review intraoperative OCT (iOCT) applications using handheld probes during surgical pauses, two-dimensional (2D) microscope-integrated OCT (MIOCT) of live surgery, and volumetric MIOCT of live surgery. The iOCT discussion focuses on technological advancements, applications during human retinal surgery, translational difficulties and limitations, and future directions.

4 April 2020 in Ophthalmology Retina
Verified
Journal Article
Closed access
LSLiangbo Linus Shen
Liangbo Linus Shen
MSMengyuan Sun
Mengyuan Sun
HNHolly K. Grossetta Nardini
Holly K. Grossetta Nardini
LPLucian V. Del Priore
Lucian V. Del Priore

1 September 2018 in Ophthalmology Retina
Verified
Journal Article
Closed access
LSLiangbo Linus Shen
Liangbo Linus Shen
FLFeimei Liu
Feimei Liu
HNHolly Grossetta Nardini
Holly Grossetta Nardini
LPLucian V. Del Priore
Lucian V. Del Priore

6 April 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
LSLiangbo Linus Shen
Liangbo Linus Shen
OCOscar Carrasco-Zevallos
Oscar Carrasco-Zevallos
BKBrenton Keller
Brenton Keller
CVChristian Viehland
Christian Viehland
GWGar Waterman
Gar Waterman
JIJoseph A. Izatt
Joseph A. Izatt
Intra-operative optical coherence tomography (OCT) requires a display technology which allows surgeons to visualize OCT data without disrupting surgery. Previous research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into surgical microscopes to provide monoscopic viewing of OCT data through one microscope ocular. To take full advantage of our previously reported real-time volumetric microscope-integrated OCT (4D MIOCT) system, we describe a stereoscopic HUD which projects a stereo pair of OCT volume renderings into both oculars simultaneously. The stereoscopic HUD uses a novel optical design employing spatial multiplexing to project dual OCT volume renderings utilizing a single micro-display. The optical performance of the surgical microscope with the HUD was quantitatively characterized and the addition of the HUD was found not to substantially effect the resolution, field of view, or pincushion distortion of the operating microscope. In a pilot depth perception subject study, five ophthalmic surgeons completed a pre-set dexterity task with 50.0% (SD = 37.3%) higher success rate and in 35.0% (SD = 24.8%) less time on average with stereoscopic OCT vision compared to monoscopic OCT vision. Preliminary experience using the HUD in 40 vitreo-retinal human surgeries by five ophthalmic surgeons is reported, in which all surgeons reported that the HUD did not alter their normal view of surgery and that live surgical maneuvers were readily visible in displayed stereoscopic OCT volumes.