Cameron Kewish

Dr. Cameron Kewish

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2010 in Nature
Verified
Journal Article
Closed access
MDMartin Dierolf
Martin Dierolf
AMAndreas Menzel
Andreas Menzel
PTPierre Thibault
Pierre Thibault
PSPhilipp Schneider
Philipp Schneider
CKCameron Kewish
Cameron Kewish
FPFranz Pfeiffer
Franz Pfeiffer

17 December 2009 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
KGKlaus Giewekemeyer
Klaus Giewekemeyer
PTPierre Thibault
Pierre Thibault
SKSebastian Kalbfleisch
Sebastian Kalbfleisch
ABAndré Beerlink
André Beerlink
CKCameron Kewish
Cameron Kewish
TSTim Salditt
Tim Salditt
Recent advances in coherent x-ray diffractive imaging have paved the way to reliable and quantitative imaging of noncompact specimens at the nanometer scale. Introduced a year ago, an advanced implementation of ptychographic coherent diffractive imaging has removed much of the previous limitations regarding sample preparation and illumination conditions. Here, we apply this recent approach toward structure determination at the nanoscale to biological microscopy. We show that the projected electron density of unstained and unsliced freeze-dried cells of the bacterium Deinococcus radiodurans can be derived from the reconstructed phase in a straightforward and reproducible way, with quantified and small errors. Thus, the approach may contribute in the future to the understanding of the highly disputed nucleoid structure of bacterial cells. In the present study, the estimated resolution for the cells was 85 nm (half-period length), whereas 50-nm resolution was demonstrated for lithographic test structures. With respect to the diameter of the pinhole used to illuminate the samples, a superresolution of about 15 was achieved for the cells and 30 for the test structures, respectively. These values should be assessed in view of the low dose applied on the order of ≃1.3·10 5 Gy, and were shown to scale with photon fluence.

1 March 2010 in New Journal of Physics
Verified
Journal Article
Open access
MDMartin Dierolf
Martin Dierolf
PTPierre Thibault
Pierre Thibault
AMAndreas Menzel
Andreas Menzel
CKCameron Kewish
Cameron Kewish
KJKonstantins Jefimovs
Konstantins Jefimovs
FPFranz Pfeiffer
Franz Pfeiffer

12 October 2011 in Optics Express
Verified
Journal Article
Closed access
PDF file
JVJoan Vila-Comamala
Joan Vila-Comamala
ADAna Diaz
Ana Diaz
MGManuel Guizar-Sicairos
Manuel Guizar-Sicairos
AMAlexandre Mantion
Alexandre Mantion
CKCameron Kewish
Cameron Kewish
CDChristian David
Christian David
We have employed ptychographic coherent diffractive imaging to completely characterize the focal spot wavefield and wavefront aberrations of a high-resolution diffractive X-ray lens. The ptychographic data from a strongly scattering object was acquired using the radiation cone emanating from a coherently illuminated Fresnel zone plate at a photon energy of 6.2 keV. Reconstructed images of the object were retrieved with a spatial resolution of 8 nm by combining the difference-map phase retrieval algorithm with a non-linear optimization refinement. By numerically propagating the reconstructed illumination function, we have obtained the X-ray wavefield profile of the 23 nm round focus of the Fresnel zone plate (outermost zone width, Δr = 20 nm) as well as the X-ray wavefront at the exit pupil of the lens. The measurements of the wavefront aberrations were repeatable to within a root mean square error of 0.006 waves, and we demonstrate that they can be related to manufacturing aspects of the diffractive optical element and to errors on the incident X-ray wavefront introduced by the upstream beamline optics.

22 December 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
JVJoan Vila-Comamala
Joan Vila-Comamala
SGSergey Gorelick
Sergey Gorelick
EFElina Färm
Elina Färm
CKCameron Kewish
Cameron Kewish
ADAna Diaz
Ana Diaz
CDChristian David
Christian David
X-ray microscopy based on Fresnel zone plates is a powerful technique for sub-100 nm resolution imaging of biological and inorganic materials. Here, we report on the modeling, fabrication and characterization of zone-doubled Fresnel zone plates for the multi-keV regime (4―12 keV). We demonstrate unprecedented spatial resolution by resolving 15 nm lines and spaces in scanning transmission X-ray microscopy, and focusing diffraction efficiencies of 7.5% at 6.2 keV photon energy. These developments represent a significant step towards 10 nm spatial resolution for hard X-ray energies of up to 12 keV.

1 March 2010 in Ultramicroscopy
Verified
Journal Article
Closed access
CKCameron Kewish
Cameron Kewish
PTPierre Thibault
Pierre Thibault
MDMartin Dierolf
Martin Dierolf
OBOliver Bunk
Oliver Bunk
AMAndreas Menzel
Andreas Menzel
FPFranz Pfeiffer
Franz Pfeiffer