Thiam Chye Lim

Prof. Thiam Chye Lim


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in Archives of Plastic Surgery
Verified
Journal Article
Open access
PDF file
ECElijah Zhengyang Cai
Elijah Zhengyang Cai
CAChuan Han Ang
Chuan Han Ang
ARAshvin Raju
Ashvin Raju
KTKong Bing Tan
Kong Bing Tan
EHEileen Chor Hoong Hing
Eileen Chor Hoong Hing
TLThiam Chye Lim
Thiam Chye Lim
Background Burn infliction techniques are poorly described in rat models. An accurate study can only be achieved with wounds that are uniform in size and depth. We describe a simple reproducible method for creating consistent burn wounds in rats. Methods Ten male Sprague-Dawley rats were anesthetized and dorsum shaved. A 100 g cylindrical stainless-steel rod (1 cm diameter) was heated to 100℃ in boiling water. Temperature was monitored using a thermocouple. We performed two consecutive toe-pinch tests on different limbs to assess the depth of sedation. Burn infliction was limited to the loin. The skin was pulled upwards, away from the underlying viscera, creating a flat surface. The rod rested on its own weight for 5, 10, and 20 seconds at three different sites on each rat. Wounds were evaluated for size, morphology and depth. Results Average wound size was 0.9957 cm2 (standard deviation [SD] 0.1845) (n=30). Wounds created with duration of 5 seconds were pale, with an indistinct margin of erythema. Wounds of 10 and 20 seconds were well-defined, uniformly brown with a rim of erythema. Average depths of tissue damage were 1.30 mm (SD 0.424), 2.35 mm (SD 0.071), and 2.60 mm (SD 0.283) for duration of 5, 10, 20 seconds respectively. Burn duration of 5 seconds resulted in full-thickness damage. Burn duration of 10 seconds and 20 seconds resulted in full-thickness damage, involving subjacent skeletal muscle. Conclusions This is a simple reproducible method for creating burn wounds consistent in size and depth in a rat burn model.

7 September 2021 in Plastic and Reconstructive Surgery
Verified
Journal Article
Closed access
ECElijah Zhengyang M.B.B.S. Cai
Elijah Zhengyang M.B.B.S. Cai
YGYujia M.B.B.S. Gao
Yujia M.B.B.S. Gao
KNKee Yuan M.B.B.S. Ngiam
Kee Yuan M.B.B.S. Ngiam
TLThiam Chye Lim
Thiam Chye Lim

Verified
Journal Article
Open access
MYMatthew S. Yeo
Matthew S. Yeo
TGTerence L.H. Goh
Terence L.H. Goh
VNVigneswaran Nallathamby
Vigneswaran Nallathamby
ECEe Cherk Cheong
Ee Cherk Cheong
TLThiam Chye Lim
Thiam Chye Lim
Mandible fractures commonly occur in patients who have sustained blunt facial trauma, and the subcondylar region is the most frequently fractured due to its intrinsic biomechanical weakness. The maxillary artery lies in close relation to the medial cortex of the subcondyle and is vulnerable to injury by the sharp edges of the fracture fragments during the initial trauma or during operative fracture reduction. Maxillary artery injuries and subcondylar fractures may be an underdiagnosed phenomenon. Yet, this is of clinical significance as the maxillary artery caliber is usually of significant caliber and may lead to substantial hemorrhage. Surgical access to the artery for hemostasis is challenging and is further compounded by small surgical incisions usually undertaken for fracture fixation, obscuring of the artery by the overlying fracture fragments, and vessel retraction following its transection. In cases where maxillary artery injury is suspected, an open surgical approach may be favored over an endoscopic one. The authors illustrate a case in which brisk hemorrhage from the maxillary artery encountered during a preauricular approach to fixation of the mandible subcondyle was successfully controlled with temporary pressure on the external carotid artery through a neck incision and direct ligation of the lacerated maxillary artery. The authors then discuss diagnosis and treatment of such maxillary artery injuries and propose a novel diagnostic and treatment algorithm.

1 November 2014 in Archives of Plastic Surgery
Verified
Journal Article
Open access
PDF file
ECElijah Zhengyang Cai
Elijah Zhengyang Cai
ETErin Yiling Teo
Erin Yiling Teo
LJLim Jing
Lim Jing
YKYun Pei Koh
Yun Pei Koh
TQTan Si Qian
Tan Si Qian
TLThiam Chye Lim
Thiam Chye Lim
Background The combination of polycaprolactone and hyaluronic acid creates an ideal environment for wound healing. Hyaluronic acid maintains a moist wound environment and accelerates the in-growth of granulation tissue. Polycaprolactone has excellent mechanical strength, limits inflammation and is biocompatible. This study evaluates the safety and efficacy of bio-conjugated polycaprolactone membranes (BPM) as a wound dressing. Methods 16 New Zealand white rabbits were sedated and local anaesthesia was administered. Two 3.0×3.0 cm full-thickness wounds were created on the dorsum of each rabbit, between the lowest rib and the pelvic bone. The wounds were dressed with either BPM (n=12) or Mepitel (n=12) (control), a polyamide-silicon wound dressing. These were evaluated macroscopically on the 7th, 14th, 21st, and 28th postoperative days for granulation, re-epithelialization, infection, and wound size, and histologically for epidermal and dermal regeneration. Results Both groups showed a comparable extent of granulation and re-epithelialization. No signs of infection were observed. There was no significant difference (P>0.05) in wound size between the two groups. BPM (n=6): 8.33 cm2, 4.90 cm2, 3.12 cm2, 1.84 cm2; Mepitel (n=6): 10.29 cm2, 5.53 cm2, 3.63 cm2, 2.02 cm2; at the 7th, 14th, 21st, and 28th postoperative days. The extents of epidermal and dermal regeneration were comparable between the two groups. Conclusions BPM is comparable to Mepitel as a safe and efficacious wound dressing.

Verified
Journal Article
Open access
CAChuanHan Ang
ChuanHan Ang
JLJinRong Low
JinRong Low
JSJiaYi Shen
JiaYi Shen
ECElijah Zheng Yang Cai
Elijah Zheng Yang Cai
EHEileen Chor Hoong Hing
Eileen Chor Hoong Hing
TLThiam Chye Lim
Thiam Chye Lim
Orbital fracture detection and size determination from computed tomography (CT) scans affect the decision to operate, the type of surgical implant used, and postoperative outcomes. However, the lack of standardization of radiological signs often leads to the false-positive detection of orbital fractures, while nonstandardized landmarks lead to inaccurate defect measurements. We aim to design a novel protocol for CT measurement of orbital floor fractures and evaluate the interobserver variability on CT scan images. Qualitative aspects of this protocol include identifying direct and indirect signs of orbital fractures on CT scan images. Quantitative aspects of this protocol include measuring the surface area of pure orbital floor fractures using computer software. In this study, 15 independent observers without clinical experience in orbital fracture detection and measurement measured the orbital floor fractures of three randomly selected patients following the protocol. The time required for each measurement was recorded. The intraclass correlation coefficient of the surface area measurements is 0.999 (0.997–1.000) with p-value < 0.001. This suggests that any observer measuring the surface area will obtain a similar estimation of the fractured surface area. The maximum error limit was 0.901 cm2 which is less than the margin of error of 1 cm2 in mesh trimming for orbital reconstruction. The average duration required for each measurement was 3 minutes 19 seconds (ranging from 1 minute 35 seconds to 5 minutes). Measurements performed with our novel protocol resulted in minimal interobserver variability. This protocol is effective and generated reproducible results, is easy to teach and utilize, and its findings can be interpreted easily.

14 February 2025 in British Journal of Dermatology
Verified
Journal Article
Open access
DSDenis C Szondi
Denis C Szondi
RCRachel A Crompton
Rachel A Crompton
LOLinus Oon
Linus Oon
NSNagavidya Subramaniam
Nagavidya Subramaniam
KTKhek-Chian Tham
Khek-Chian Tham
SCSheena M Cruickshank
Sheena M Cruickshank
Background: Arginase 1 (ARG1) is an enzyme expressed by keratinocytes that drives several functions linked to skin barrier function. However, the mechanisms underpinning keratinocyte ARG1 function in barrier homeostasis have not been fully elucidated. Atopic dermatitis (AD) is linked to impaired skin barrier via altered keratinocyte differentiation and susceptibility to infection. Objectives: To investigate the role of ARG1 in keratinocyte differentiation and antimicrobial responses. Methods: In vitro two-dimensional differentiation assays using ARG knockdown or ARG inhibited keratinocytes were used to explore the function of ARG1 in keratinocyte differentiation and barrier formation. ARG1 was also assessed in an ex vivo model of AD. Results: ARG1 was strongly expressed in the apical layers of human skin, corresponding to high ARG1 expression in late differentiated ­keratinocytes. ARG was downregulated in an ex vivo AD model relative to control, suggesting that altered ARG1 is clinically relevant. ARG1 ­inhibition in keratinocytes led to a significant decrease in the late differentiation markers filaggrin, involucrin and loricrin, and significant downregulation of antimicrobial peptides (AMPs), lipocalin 2, kallikreins and small proline-rich proteins. ARG forms part of the urea cycle and the action of ARG on L-arginine causes the production of L-ornithine and urea. In turn, L-ornithine is catabolized for putrescine production. Supplementation with ARG products, putrescine and urea could rescue late keratinocyte differentiation and AMP expression in ARG-deficient cells. Conclusions: ARG1 activity plays a major role in keratinocyte differentiation and AMP production. ARG1 is downregulated in an AD model, and in cell systems its function can be rescued by the ARG1 downstream products putrescine and urea. Manipulation of the ARG1 pathway may have the potential to be used for the management of skin conditions such as AD.