The use of thinner membranes in polymer electrolyte water electrolysis increases the likelihood of forming an explosive H2/O2 mixture in the anode stream. Doping Pt nanoparticles into a Nafion membrane as recombination catalyst effectively lowers the hydrogen crossover. Here, we propose the additional co-doping of cerium-zirconium oxide as radical scavenger to mitigate membrane degradation. Our results show over 4-fold reduction of anodic hydrogen content compared to a non-doped membrane, and a nearly 3-fold decrease of fluoride release rate compared to the membrane with only Pt-doping at 80 °C and differential pressure (pc = 3 bar, pa = 1 bar) operation.
The impeding ban on per- and polyfluoroalkyl substances (PFAS) prompted researchers to focus on hydrocarbon-based materials as constituents of next-generation proton exchange membranes (PEMs) for polymer electrolyte fuel cells (PEFCs). Here, we report on the fuel cell performance and durability of fluorine-lean PEMs prepared by the post-sulfonation of co-grafted α-methylstyrene (AMS) and 2-methylene glutaronitrile (MGN) monomers into preirradiated 12 µm polyvinylidene fluoride (PVDF) base film. The membranes were subjected to two distinctly different accelerated stress test (AST) protocols performed at open-circuit voltage (OCV): the US Department of Energy-similar chemical AST (90 °C, 30% relative humidity (RH), H2/air, 1 bara), developed originally for perfluoroalkylsulfonic acid (PFSA) membranes, and the high relative humidity AST (80 °C, 100% RH, H2/O2, 2.5 bara), designed for aromatic hydrocarbon membranes. We found that doping the grafted membranes with a metalated porphyrin antioxidant can simultaneously reduce membrane aging and improve fuel cell performance.
Polymer electrolyte water electrolysis (PEWE) is one of the key technologies for green hydrogen production. It has the advantages of operating at relatively high current densities and differential pressures. The hydrogen gas produced, under high cathodic pressure and with a thin membrane, tends to cross over to the anode chamber, forming explosive H2/O2 gas mixture and posing severe safety concerns for the device. Literature has shown that one effective solution is the use of Pt as the recombination catalyst. On the other hand, radical attacks to the PFSA-based membrane leads to possible thinning and pinhole formation, which deteriorates the electrochemical performance and eventually causes cell failure. To this end, ceria is often employed as a radical scavenger. In this work, we report the co-incorporation of Pt and cerium-zirconium oxide in solution-cast Nafion membranes for the dual functions of suppressing hydrogen crossover and scavenging of radicals. We show that the hydrogen in oxygen content in the anode gas stream is significantly reduced with the incorporation of Pt, and the inclusion of cerium-zirconium oxide inside the membrane is able to decrease fluoride release rate in a 100-hour constant-current water electrolysis measurement. This study provides guidance in developing proton exchange membranes with enhanced durability and safe operating range.
Hydrocarbon proton exchange membranes (PEMs) for fuel cells have recently received increased attention due to growing environmental concerns about the use of per- and polyfluoroalkyl substances. The chemical accelerated stress test (AST) protocol for membranes developed by the US Department of Energy (DOE), which is based on the understanding of the degradation mechanism of perfluoroalkylsulfonic acid PEMs, has been widely adopted to assess newly developed hydrocarbon PEMs. However, due to different polymer chemistry and membrane degradation mechanisms, the DOE chemical AST protocol may not be suitable for hydrocarbon PEMs. In this study, the influence of two key operating parameters, i.e. relative humidity (RH) and O2 partial pressure (pO2), on the chemical degradation of hydrocarbon PEMs was investigated in order to design a more suitable chemical AST protocol for hydrocarbon PEMs. Sulfonated poly(ether ether ketone) (SPEEK) was selected as a representative material for non-fluorinated hydrocarbon PEMs. Solution-cast membranes of ~22 μm thickness were wet-assembled in a single fuel cell (16 cm2 active area) for fixed time (4 days) open circuit voltage (OCV) holding tests at different RHs and pO2. Under 100% RH, H2/O2, the membrane failed the fastest within 40 hours (Figure 1a). This could be related to higher gas crossover (Figure 1b), which leads to more oxidative radicals, such as HO•, being generated. Fuel cell effluent water was periodically collected from both the anode and cathode sides for analysis by UV-vis spectroscopy and ion chromatography (IC). Hydroquinone-like degradation products were detected by UV-vis spectroscopy. Furthermore, under 100% RH, H2/O2, the degradation products showed the strongest signal in the anodic effluent water. IC results of sulfate ion release suggested that the higher the RH (also pO2), the more severe the membrane degradation. Post-test ion exchange capacity (IEC) measurements showed that the average IEC loss rate is the highest under 100% RH, H2/O2 (~0.15 %/h), while the lowest under 30% RH, H2/air (~0.01 %/h), again indicating that 100% RH, H2/O2 could be a promising protocol for AST of hydrocarbon PEMs. Figure 1