Lobat Tayebi

Dr. Lobat Tayebi


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
MRMehdi Razavi
Mehdi Razavi
MFMohammadhossein Fathi
Mohammadhossein Fathi
OSOmid Savabi
Omid Savabi
DVDaryoosh Vashaee
Daryoosh Vashaee
LTLobat Tayebi
Lobat Tayebi

1 August 2014 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
MRMehdi Razavi
Mehdi Razavi
MFMohammadhossein Fathi
Mohammadhossein Fathi
OSOmid Savabi
Omid Savabi
DVDaryoosh Vashaee
Daryoosh Vashaee
LTLobat Tayebi
Lobat Tayebi

1 May 2014 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
MRMehdi Razavi
Mehdi Razavi
MFMohammadhossein Fathi
Mohammadhossein Fathi
OSOmid Savabi
Omid Savabi
BBBatoul Hashemi Beni
Batoul Hashemi Beni
DVDaryoosh Vashaee
Daryoosh Vashaee
LTLobat Tayebi
Lobat Tayebi

1 December 2013 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
LTLobat Tayebi
Lobat Tayebi
ASAref Shahini
Aref Shahini
Mostafa YazdimamaghaniMostafa Yazdimamaghani
Mostafa Yazdimamaghani
KWKenneth Jimmy Walker
Kenneth Jimmy Walker
MEMargaret Eastman
Margaret Eastman
DVDaryoosh Vashaee
Daryoosh Vashaee
Bone healing can be significantly expedited by applying electrical stimuli in the injured region. Therefore, a three-dimensional (3D) ceramic conductive tissue engineering scaffold for large bone defects that can locally deliver the electrical stimuli is highly desired. In the present study, 3D conductive scaffolds were prepared by employing a biocompatible conductive polymer, ie, poly(3,4-ethylenedioxythiophene) poly(4-styrene sulfonate) (PEDOT:PSS), in the optimized nanocomposite of gelatin and bioactive glass. For in vitro analysis, adult human mesenchymal stem cells were seeded in the scaffolds. Material characterizations using hydrogen-1 nuclear magnetic resonance, in vitro degradation, as well as thermal and mechanical analysis showed that incorporation of PEDOT:PSS increased the physiochemical stability of the composite, resulting in improved mechanical properties and biodegradation resistance. The outcomes indicate that PEDOT:PSS and polypeptide chains have close interaction, most likely by forming salt bridges between arginine side chains and sulfonate groups. The morphology of the scaffolds and cultured human mesenchymal stem cells were observed and analyzed via scanning electron microscope, micro-computed tomography, and confocal fluorescent microscope. Increasing the concentration of the conductive polymer in the scaffold enhanced the cell viability, indicating the improved microstructure of the scaffolds or boosted electrical signaling among cells. These results show that these conductive scaffolds are not only structurally more favorable for bone tissue engineering, but also can be a step forward in combining the tissue engineering techniques with the method of enhancing the bone healing by electrical stimuli.

28 August 2013 in Materials
Verified
Journal Article
Open access
PDF file
Mostafa YazdimamaghaniMostafa Yazdimamaghani
Mostafa Yazdimamaghani
TPTannaz Pourvala
Tannaz Pourvala
EMElaheh Motamedi
Elaheh Motamedi
BFBabak Fathi
Babak Fathi
DVDaryoosh Vashaee
Daryoosh Vashaee
LTLobat Tayebi
Lobat Tayebi
Nanocomposites of encapsulated silica nanoparticles were prepared by in situ emulsion polymerization of acrylate monomers. The synthesized material showed good uniformity and dispersion of the inorganic components in the base polymer, which enhances the properties of the nanocomposite material. A nonionic surfactant with lower critical solution temperature (LCST) was used to encapsulate the silica nanoparticles in the acrylic copolymer matrix. This in situ method combined the surface modification and the encapsulation in a single pot, which greatly simplified the process compared with other conventional methods requiring separate processing steps. The morphology of the encapsulated nanosilica particles was investigated by dynamic light scattering (DLS) and transmission electron microscopy (TEM), which confirmed the uniform distribution of the nanoparticles without any agglomerations. A neat copolymer was also prepared as a control sample. Both the neat copolymer and the prepared nanocomposite were characterized by Fourier transform infrared spectroscopy (FTIR), thermal gravimetric analyses (TGA), dynamic mechanical thermal analysis (DMTA) and the flame resistance test. Due to the uniform dispersion of the non-agglomerated nanoparticles in the matrix of the polymer, TGA and flame resistance test results showed remarkably improved thermal stability. Furthermore, DMTA results demonstrated an enhanced storage modulus of the nanocomposite samples compared with that of the neat copolymer, indicating its superior mechanical properties.

1 April 2013 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
MMMasoud Mozafari
Masoud Mozafari
LTLobat Tayebi
Lobat Tayebi
Erfan SalahinejadErfan Salahinejad
Erfan Salahinejad
VSVahid Shabafrooz
Vahid Shabafrooz
Mostafa YazdimamaghaniMostafa Yazdimamaghani
Mostafa Yazdimamaghani
DVDaryoosh Vashaee
Daryoosh Vashaee
Surface modification, particularly coatings deposition, is beneficial to tissue-engineering applications. In this work, bioactive glass/zirconium titanate composite thin films were prepared by a sol-gel spin-coating method. The surface features of the coatings were studied by scanning electron microscopy, atomic force microscopy, and spectroscopic reflection analyses. The results show that uniform and sound multilayer thin films were successfully prepared through the optimization of the process variables and the application of carboxymethyl cellulose as a dispersing agent. Also, it was found that the thickness and roughness of the multilayer coatings increase nonlinearly with increasing the number of the layers. This new class of nanocomposite coatings, comprising the bioactive and inert components, is expected not only to enhance bioactivity and biocompatibility, but also to protect the surface of metallic implants against wear and corrosion.