Yuhua Wang

Dr. Yuhua Wang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in International Immunopharmacology
Verified
Journal Article
Closed access
XMXueying Ma
Xueying Ma
XCXin Chen
Xin Chen
ZDZhonghua Duan
Zhonghua Duan
YWYuqiong Wu
Yuqiong Wu
JSJiaen Shu
Jiaen Shu
YWYuhua Wang
Yuhua Wang

21 March 2024 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
JSJiaen Shu
Jiaen Shu
YHYijia Huang
Yijia Huang
XMXueying Ma
Xueying Ma
ZDZhonghua Duan
Zhonghua Duan
PWPei Wu
Pei Wu
YWYuhua Wang
Yuhua Wang
Treating white spot lesions (WSLs) with resin infiltration alone may not be sufficient, raising questions about its compatibility with other treatments amid controversial or incomplete data. Therefore, this study aimed to assess the aesthetic feasibility of resin infiltration combined with bleaching, as well as its potential mechanical effect on ceramic bonding to WSLs. One hundred and fifty flat enamel surfaces of bovine incisors were prepared. Ninety specimens were deminerailized and randomly assigned to three groups(n = 30): post-bleaching resin infiltration (Bl-R), pre-bleaching resin infiltration (R-Bl), and only resin infiltration (R). Color, surface roughness and microhardness were assessed in immediate, thermocycling and pigmentation tests. The remaining sixty samples were randomly assigned to three groups (n = 20): control (Ctrl), bonding (Bo), pre-bonding resin infiltration (R-Bo). Shear bonding strength, failure mode, micro-leakage depth and interface morphology were evaluated after ceramic bonding. The Tukey test and analysis of variance (ANOVA) were used for statistical analysis. For the effect of resin infiltration and bleaching on WSLs, the R-Bl group showed the worst chromic masking ability, with the highest |ΔL|, |Δa|, |Δb|, and ΔE values after treatment. Compared with those in the Bl-R group, the R-Bl and R groups showed significant time-dependent staining, which is possibly attributed to their surface roughness. For the effect of resin infiltration on the adhesive properties of WSLs, resin infiltration reduced the staining penetration depth of WSLs from 2393.54 ± 1118.86 μm to 188.46 ± 89.96 μm (P < 0.05) while reducing WSLs porosity in SEM observation. Post-bleaching resin infiltration proved to be advantageous in the aesthetic treatment of WSLs. Resin infiltration did not compromise bonding strength but it did reduce microleakage and enhance marginal sealing. Overall, resin infiltration can effectively enhance the chromatic results of treated WSLs and prevent long-term bonding failure between ceramics and enamel. Based on these findings, the use of post-bleaching resin infiltration is recommended, and resin infiltration before ceramic bonding is deemed viable in clinical practice.

30 April 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
YLYujia Liu
Yujia Liu
YHYijia Huang
Yijia Huang
SCSijing Chu
Sijing Chu
QFQiangqiang Fu
Qiangqiang Fu
HLHaixia Liu
Haixia Liu
YWYuhua Wang
Yuhua Wang
How the connector shape, retainer type, and retainer placement affect the functional stresses in lithium disilicate cantilever resin-bonded fixed partial dentures (RBFPDs) is unclear. The purpose of this finite element analysis (FEA) study was to evaluate the effects of the connector shape, retainer type, and retainer placement on the stress distribution and magnitude of stress in RBFPDs. Cantilever RBFPDs of the maxillary anterior lateral incisor with a retainer on the canine were modeled to conduct a 3-dimensional FEA. These designs were divided into 2 groups based on connector shape: rectangular and trapezoidal. Each group included 4 different retainer configurations-either labial or palatal veneer RBFPDs (LV-RBFPD or PV-RBFPD) or labial or palatal contact-point RBFPDs (LC-RBFPD or PC-RBFPD). FEA was performed for each RBFPD to evaluate stresses during regional and 3-point loading, including maximal intercuspal, protrusive, and lateral mandibular positions. The results were evaluated via colorimetric stress maps of the equivalent von Mises stress, maximum principal stress, and minimum principal stress in the prosthesis. The connector shape, retainer type, and placement affected the RBFPD stress, and the lowest stress was observed in the rectangular group. The LC-RBFPD group presented the lowest maximum principal stress (348.2 MPa) and minimum principal stress (49.1 MPa) under regional loading and the lowest equivalent stress (273.4 MPa) and maximum principal stress (356.0 MPa) with the protrusion position. The LV-RBFPD group presented the lowest equivalent stress (52.0 MPa), the lowest maximum principal stress (47.5 MPa), and the minimum principal stress (1.04 MPa) at the maximal intercuspal position, the lowest minimum principal stress (1.04 MPa) at the protrusion position, and the lowest equivalent stress (46.7 MPa) at the lateral position. The PV-RBFPD group presented the lowest equivalent stress (268.5 MPa) under regional loading and the lowest maximum principal stress (37.7 MPa) and minimum principal stress (2.02 MPa) under lateral loading. A rectangular cross-sectional connector design for all groups could help disperse occlusal force and improve the resistance of the restoration. Both the veneer and contact-point retainer in the rectangular group were clinically acceptable and could resist fracture.

5 November 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
SCSijing Chu
Sijing Chu
YWYizhou Wang
Yizhou Wang
ZDZhonghua Duan
Zhonghua Duan
PWPei Wu
Pei Wu
YWYuhua Wang
Yuhua Wang
To assess the bleaching efficacy, tooth sensitivity, enamel surface morphology, and oral health-related quality of life (OHRQoL) of two at-home bleaching products with matched effective hydrogen peroxide (HP) concentrations: Beyke iWhite (8% carbamide peroxide) and Invisalign (3% hydrogen peroxide). A randomized, triple-blind, split-mouth clinical trial was conducted with 22 participants undergoing a two-week bleaching treatment. The gel was used daily for 6–8 h. Tooth color and OHRQoL were assessed at baseline, post-bleaching, and 1-month follow-up. Tooth color was measured using a spectrophotometer (ΔE00), while OHRQoL was evaluated using psychological questionnaires (OHIP and PIDAQ questionnaires). Daily tooth sensitivity reports were collected, and enamel morphology was analyzed using scanning electron microscopy. An in vitro experiment tracked the initial pH values of gels and their 8 h changes on bovine enamel. Statistical analysis included Wilcoxon Signed Rank tests for tooth sensitivity and questionnaires, paired t-tests for color change (ΔE00), and ANOVA for pH changes. Both products presented effective color change (ΔE00 = 5.39 ± 2.50 for 3% HP and ΔE00 = 4.75 ± 2.25 for 8% CP) after two weeks, exceeding clinical acceptability thresholds (ΔE00 >1.8). The 3% HP gel yielded a statistically greater color change than the 8% CP gel (p < 0.05). The 8% CP gel induced statistically lower tooth sensitivity (NRS/VAS, p < 0.05), while both reported mild sensitivity (0 < NRS < 1.5, 0 < VAS < 3). OHRQoL improved significantly (P < 0.05). Invisalign treatment led to more noticeable surface undulations than Beyke iWhite. The in vitro experiment indicated Beyke iWhite gel was initially alkaline, turning neutral, while Invisalign gel remained acidic. Both products effectively whitened teeth while inducing mild tooth sensitivity, and both had a positive socio-psychological impact. The 3% HP gel provided a bleaching efficacy advantage, while the 8% CP gel demonstrated lower sensitivity and less enamel alteration. Clinicians may consider at-home bleaching techniques with 3% HP and 8% CP to obtain effective bleaching results with slight side effects. Chinese Clinical Trial Registry ChiCTR2400092807, 24/11/2024, Retrospectively registered.

24 March 2026 in BMC Medical Education
Verified
Journal Article
Open access
YWYizhou Wang
Yizhou Wang
QFQiping Feng
Qiping Feng
SCSijing Chu
Sijing Chu
YHYijia Huang
Yijia Huang
CXChun Xu
Chun Xu
YWYuhua Wang
Yuhua Wang
This pilot randomized controlled trial evaluated the effectiveness of an artificial intelligence (AI)–assisted solo workflow for intraoral photography training. The study examined whether real‑time AI feedback could enhance photographic quality, procedural efficiency, learner self‑efficacy, and patient comfort compared with conventional approaches. Fifty-four first‑year dental students were randomly assigned to one of three groups: assistant‑supported workflow (four‑handed technique, control), solo workflow without AI support, and solo workflow with AI‑driven real‑time feedback. All participants performed standardized intraoral photography tasks. The primary outcome was a composite photographic quality score derived from expert ratings of three standardized intraoral views (frontal intercuspal, frontal open-bite, and lateral intercuspal), each rated on a 0–10 scale (total range 0–30). Data were analyzed using ANOVA; mean differences (MD) with 95% confidence intervals (CI) were calculated. Inter‑rater reliability for expert image ratings was good (ICC = 0.84, 95% CI: 0.72 to 0.90). The AI-supported solo group achieved the highest composite quality scores (18.2 ± 2.7). This was significantly superior to the unassisted solo group (15.8 ± 3.3), with a mean difference (MD) of 2.4 points (95% CI: 0.45 to 4.35; p = 0.027) and a large effect size (Cohen’s d = 0.80). Compared to the assistant-supported group (17.1 ± 2.1), the difference was not statistically significant (MD = 1.1; 95% CI: -0.65 to 2.85; p = 0.28). Secondary outcomes, including task completion time (F(2,51) = 1.25, p = 0.30), self‑efficacy (all p > 0.40), and patient‑reported comfort (χ²(4, N = 54) = 5.2, p = 0.27), showed no significant between‑group differences. In this single‑centre pilot trial, an AI‑assisted solo workflow enabled novice dental students to achieve higher intraoral photographic quality than unguided solo operation, with performance broadly comparable to a conventional four‑handed assistant‑supported workflow and without detectable compromises in efficiency, self‑efficacy, or patient‑reported comfort. These preliminary findings may serve as a valuable adjunct for autonomous skill acquisition, warranting further validation in larger, multi-institutional cohorts. Not applicable. This study evaluated an educational training intervention rather than a clinical treatment, and prospective trial registration was not required under institutional policy at the time of initiation. Ethical approval was obtained from Shanghai Ninth People’s Hospital Ethics Committee (SH9H-2022-T30-1). The online version contains supplementary material available at 10.1186/s12909-026-08925-1.

28 May 2026 in Life Sciences
Verified
Journal Article
Closed access
PWPei Wu
Pei Wu
YWYizhou Wang
Yizhou Wang
SCSijing Chu
Sijing Chu
ZDZhonghua Duan
Zhonghua Duan
XLXiaobo Li
Xiaobo Li
YWYuhua Wang
Yuhua Wang