Chad G Rose

Dr. Chad G Rose

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CRChad G Rose
Chad G Rose
MOMarcia K. O'Malley
Marcia K. O'Malley
A hybrid hand exoskeleton, leveraging rigid and soft elements, has been designed to serve as an assistive device to return the ability to perform activities of daily living (ADL) and improve quality of life for a broad population with hand impairment. This glove-like exoskeleton, the SeptaPose Assistive and Rehabilitative (SPAR) Glove, is underactuated, enabling seven hand poses which support most ADLs. The device resides on the spectrum between traditional rigid devices and the latest soft robotic designs. It includes novel ergonomic elements for power transmission and additional features to enable self-donning and doffing. Embedded sensors enable pose estimation and intent detection for intuitive control of the glove. In this paper, we summarize the overall design of the glove, and present details of the novel rigid palm bar and hyperextension prevention elements. We characterize the grasp force and range of motion (ROM) of the glove, and present initial feedback from an end user. The SPAR Glove meets or exceeds the functional requirements of ADLs for both ROM and grasp force. Additionally, the glove exceeds the grasp force capabilities of comparable devices, while simultaneously offering the highest number of poses. In addition to its role as an assistive device, the SPAR Glove exoskeleton has the potential to provide “hands-in” rehabilitation, centered on performing functional tasks. In the near term, the glove is a highly capable prototype for exploring hybrid assistive device design, intent detection, and user interface research.

5 July 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
CRChad G Rose
Chad G Rose
EPEvan Pezent
Evan Pezent
CKClaudia K. Kann
Claudia K. Kann
ADAshish Deshpande
Ashish Deshpande
MOMarcia K. O'MAlley
Marcia K. O'MAlley
Robotic devices have been proposed to meet the rising need for high intensity, long duration, and goal-oriented therapy required to regain motor function after neurological injury. Complementing this application, exoskeletons can augment traditional clinical assessments through precise, repeatable measurements of joint angles and movement quality. These measures assume that exoskeletons are making accurate joint measurements with a negligible effect on movement. For the coupled and coordinated joints of the wrist and hand, the validity of these two assumptions cannot be established by characterizing the device in isolation. To examine these assumptions, we conducted three user-in-the-loop experiments with able-bodied participants. First, we compared robotic measurements to an accepted modality to determine the validity of joint- and trajectorylevel measurements. Then, we compared those movements to movements without the device to investigate the effects of device dynamic properties on wrist movement characteristics. Lastly, we investigated the effect of the device on coordination with a redundant, coordinated pointing task with the wrist and hand. For all experiments, smoothness characteristics were preserved in the robotic kinematic measurement and only marginally impacted by robot dynamics, validating the exoskeletons for use as assessment devices. Stemming from these results, we propose design guidelines for exoskeletal assessment devices.

1 June 2019
Verified
Conference Paper
Closed access
AOAna C. de Oliveira
Ana C. de Oliveira
CRChad G Rose
Chad G Rose
KWKevin Warburton
Kevin Warburton
EOEvan M. Ogden
Evan M. Ogden
BWBob Whitford
Bob Whitford
ADAshish Deshpande
Ashish Deshpande
Harmony is a bimanual upper-limb exoskeleton designed for post-stroke rehabilitation. It moves the subject's shoulders and arms through their entire ranges of motion while maintaining natural coordination, is capable of force/torque control of each joint, and is equipped with sensors to measure motions and interaction forces. With these capabilities Harmony has the potential to assess motor function and create individualized therapy regimens. As a first step, five stroke survivors underwent rehabilitation sessions practicing multijoint movements with the device. Each participant performed a total of 1130 motions over seven hours of therapy with no adverse effects reported by participants or the attending therapist, supporting the suitability of Harmony for use in a clinical setting. Donning and doffing time averaged 3.5 minutes and decreased with therapist experience. Reported levels of stress, anxiety, and pain indicate that the Harmony safely assisted in the completion of the trained movements and has great potential to motivate and engage patients. We developed a novel methodology for assessing coordination capability and results from the study indicate that Harmony can enable therapists to identify neuromuscular weakness and maladaptive coordination patterns and develop targeted interventions to address these aspects of upper-limb function. The results suggest Harmony's feasibility and show promising improvements, motivating future study to gain statistical support.

5 January 2025 in Electronics
Verified
Journal Article
Open access
PDF file
FSFabian Schirmer
Fabian Schirmer
PKPhilipp Kranz
Philipp Kranz
CRChad G Rose
Chad G Rose
Jan SchmittJan Schmitt
Jan Schmitt
TKTobias Kaupp
Tobias Kaupp
The combination of human cognitive skills and dexterity with the endurance and repeatability of robots is a promising approach to modern assembly. However, efficiently allocating tasks and planning an assembly sequence between humans and robots is a manual, complex, and time-consuming activity. This work presents a framework named “Extract–Enrich–Assess–Plan–Review” that facilitates holistic planning of human–robot assembly processes. The framework automatically Extracts data from heterogeneous sources, Assesses the suitability of each assembly step to be performed by the human or robot, and Plans multiple assembly sequence plans (ASP) according to boundary conditions. Those sequences allow for a dynamic adaptation at runtime and incorporate different human–robot interaction modalities that are Synchronized, Cooperative, or Collaborative. An expert remains in the loop to Enrich the extracted data, and Review the results of the Assess and Plan steps with options to modify the process. To experimentally validate this framework, we compare the achieved degree of automation using three different CAD formats. We also demonstrate and analyze multiple assembly sequence plans that are generated by our system according to process time and the interaction modalities used.

28 April 2024 in American Journal of Pharmaceutical Education
Verified
Journal Article
Closed access
KGKimberly Garza
Kimberly Garza
BDBrandy Davis
Brandy Davis
JKJacob Kelley
Jacob Kelley
ARAlexicia Richardson
Alexicia Richardson
CSCheryl Seals
Cheryl Seals
AGAdelia Grabowsky
Adelia Grabowsky

1 July 2017 in IEEE International Conference on Rehabilitation Robotics (ICORR)
Verified
Conference Paper
Closed access
CRChad G Rose
Chad G Rose
CKClaudia K. Kann
Claudia K. Kann
ADAshish D. Deshpande
Ashish D. Deshpande
MOMarcia K. O'Malley
Marcia K. O'Malley
Robotic exoskeletons can provide the high intensity, long duration targeted therapeutic interventions required for regaining motor function lost as a result of neurological injury. Quantitative measurements by exoskeletons have been proposed as measures of rehabilitative outcomes. Exoskeletons, in contrast to end effector designs, have the potential to provide a direct mapping between human and robot joints. This mapping rests on the assumption that anatomical axes and robot axes are aligned well, and that movement within the exoskeleton is negligible. These assumptions hold well for simple one degree-of-freedom joints, but may not be valid for multi-articular joints with unique musculoskeletal properties such as the wrist. This paper presents an experiment comparing robot joint kinematic measurements from an exoskeleton to anatomical joint angles measured with a motion capture system. Joint-space position measurements and task-space smoothness metrics were compared between the two measurement modalities. The experimental results quantify the error between joint-level position measurements, and show that exoskeleton kinematic measurements preserve smoothness characteristics found in anatomical measures of wrist movements.