Ana-Maria Titoiu

Ms. Ana-Maria Titoiu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
SDSorin David
Sorin David
RMRaluca Munteanu
Raluca Munteanu
ATAna-Maria Titoiu
Ana-Maria Titoiu
IPIonela-Cristina Petcu
Ionela-Cristina Petcu
ICIoana-Cristina Cernat
Ioana-Cristina Cernat
Eugen GheorghiuEugen Gheorghiu
Eugen Gheorghiu
The problem of rapidly detecting pathogens directly from clinical samples poses significant analytical challenges. Addressing this issue in relation to urinary tract infections, we propose an effective protocol and related immunomagnetic test kits enabling versatile screening for the presence of pathogenic bacteria in unprocessed urine samples. To achieve this, the components of a typical immunomagnetic separation protocol were optimized towards the sensitive assessment of the aggregates formed out of immunomagnetically tagged target pathogens collected from clinical samples. Specifically, a dedicated immunomagnetic material was developed via the functionalization of standardized, micron-sized magnetic beads with generic antibodies against gram-specific bacterial constituents with mannan binding lectin. As such, we demonstrate efficient procedures for achieving the enhanced, specific, and pathogen-mediated cluster formation of these tailored affinity-coated magnetic beads in complex samples. We further show how cluster analysis, in conjunction with the use of nonspecific, inexpensive fluorescent dye, allows for a straightforward optical assessment of the bacterial load directly from urine samples. The optimized sensing protocol and related kits provide, in less than 60 min, qualitative (positive/negative) information on the bacterial load with 85% specificity and 96% sensitivity, which is appropriate to empower clinical microscopy with a new analytic dimension. The procedure is prone to automation, can be conveniently used in clinical microbiology laboratories and, since it preserves the viability of the captured bacteria, can be interfaced with downstream analyses and antimicrobial susceptibility testing. Moreover, the study emphasizes a suite of practical validation assays that are useful for bringing the tool-box of immunomagnetic materials outside the academic laboratory and into real-life applications.