Thousands of multi-span, simply supported beam bridges with short or medium spans have been built in China. They often suffer from problems of cracks in the link slabs over piers, and the deterioration and damage of deck expansion joints at abutments. To address these problems, one approach is to retrofit them by converting the simply supported box beams into continuous structures over the piers and jointless bridges over the abutments. This paper discusses the design methodology and details for retrofitting the Jinpu Bridge in Zhangzhou, Fujian, China, from a simply supported bridge into a semi-integral bridge, in which semi-fixed dowel joints are used to connect the superstructure and the substructure, including piers and abutments. Simultaneously, the finite element software is used to calculate the internal forces and displacements of the structure. The analysis reveals an 11.1% reduction in the maximum positive moment at the midspan of the main beam in the semi-integral bridge compared to the simply supported bridge. However, the shear forces at the interior pier increase by 6.4%. According to the response spectrum analysis, the maximum longitudinal displacement of the semi-integral bridge’s main beam is 11.6 mm, reduced by 80.1% compared to the simply supported bridge under a dead load and earthquake effects. The maximum bending moment and shear force on the pier of the semi-integral bridge are 984.7 kN·m and 312.6 kN, respectively, both below their ultimate bearing capacities. The maximum displacement at the top of the pier is 7.7 mm, which is below the allowable 52.4 mm displacement. The calculated results conform to the design requirements specified by the code.
The semi-fixed dowel joint studied in this paper consists of a steel dowel with rubber sleeves and a rubber pad to connect the superstructure and the substructure and to support the main beam. This type of joint is suitably used in retrofitting a jointed bridge with high-stiffness substructure into a semi-integral bridge. This study aimed to investigate the nonlinear stiffness of the joint, which is the key parameter in the retrofitting design. Taking the real joint in a retrofitted semi-integral bridge as a prototype, tests on full-scale models were carried out, in which the wall thickness of the rubber sleeve and the thickness of the rubber pad were taken as parameters. The test results show that the wall thickness of the rubber sleeve is the main factor affecting the radial stiffness and the flexural stiffness of the semi-fixed dowel joint. With the decrease of the wall thickness of the rubber sleeve, the radial stiffness decreases while the flexural stiffness increases. However, the thickness of the rubber pad has little influence on both the radial and flexural stiffness of the joint, and its main role is only vertical loading-bearing. If the longitudinal deformation of the main beam of a bridge under maximum temperature variation is 10 mm as the allowance value of engineering design, the wall thickness of the rubber sleeve for this joint should not be less than 40 mm. At last, on the basis of experimental research and theoretical analysis, the formulas of radial stiffness and flexural stiffness are fitted; it can be used as reference for practical engineering application, or for formulation of relevant specifications.
Thousands of multi-span, simply supported, beam bridges with short or medium spans have been built in China. They often suffer from problems of cracks in the link slabs over piers, and deterioration and damage of deck expansion joints at abutments. To address these problems, one approach is to retrofit them by converting the simply supported box beams into continuous structures over the piers and jointless bridges over the abutments. This paper discusses the design methodology and details for retrofitting the Jinpu Bridge in Zhangzhou, Fujian, China, from a simply supported bridge into a semi-integral bridge, in which semi-fixed dowel joints are used to connect the superstructure and the substructure, including piers and abutments. Simultaneously, the finite element software is used to calculate the internal forces and displacements of the structure. The analysis reveals an 11.1% reduction in the maximum positive moment at the midspan of the main beam in the semi-integral bridge compared to the simply supported bridge. However, the shear forces at the interior pier increase by 6.4%. According to the response spectrum analysis, the maximum longitudinal displacement of the semi-integral bridge's main beam is 11.6 mm, reduced by 80.1% compared to the simply supported bridge under dead load and earthquake effects. The maximum bending moment and shear force on the pier of the semi-integral bridge are 984.7 kN·m and 312.6kN, respectively, both below their ultimate bearing capacities. The maximum displacement at the top of the pier is 7.7 mm, below the allowable 52.4 mm displacement. The calculated results conform to the design requirements specified by the code.